![Pepperl+Fuchs ECOM Ident-Ex 01 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/pepperl-fuchs/ecom-ident-ex-01/ecom-ident-ex-01_operating-instructions-manual_1527611008.webp)
8
Lost connection:
If the Ident-Ex 01 lost the SPP connection (e.g. out of range), the SPP and Blue-
tooth LED goes out and a new connection with SPP-Profile must be established
(if the Ident-Ex 01 is in range).
Generic:
If the Ident-Ex 01 is connected with SPP-Profile with a input device, data can be
transferred to or from the Ident-Ex 01.
Functions:
• Use of the serial protocol
Data can be transferred to or from the Ident-Ex 01 with the serial protocol,
e.g. read firmware version, Bluetooth-address or change each settings point
directly at the Ident-Ex 01
• Transfer settings (XML-File)
All settings for the Ident-Ex 01 will be saved in a XML-File and can be transfer-
red to the Ident-Ex 01 via Bluetooth and XModem1k transfer
• Use a Keyboard Wedge
• Firmware update
18. Batch Mode
If the Ident-Ex is not connected via Bluetooth (HID or SPP mode) to a device, all
scans will be stored in the internal storage. It can store up to 511 scans. These
stored scans can be readout from the Ident-Ex 01 if connected via SPP-Profile.
If the internal storage is full, no new scan can be made until the memory was
readout and erased. See Software Manual (DOCT-7016) for further information’s.
Erase last scan with Trigger or Main-Trigger Button:
It is possible to delete the last scan with the Trigger or Main-Trigger Buttons
(see “Trigger” and “Main-Trigger” settings in the Software Manual DOCT-7016).
The last scan can only be erased if the Ident-Ex 01 is not connected to a input
device (SPP and Bluetooth LED off).
Содержание ECOM Ident-Ex 01
Страница 1: ...1 Bluetooth Scanner Ident Ex 01 Operating instructions Zone 1 21 DIV 1...
Страница 11: ...11...