IX34510a_e.doc / Apr-11
Page 39 / 43
7.2.
Technical Specifications
Supply voltage AC
: 115/230 V (+/- 12.5 %)
Supply voltage DC
: 24 V (17 – 30 V)
Consumption (without sensor)
: 17 V: 190 mA, 24 V: 150 mA, 30 V: 120 mA
AC Power
: 7.5 VA
Aux. output for encoder
: 24 VDC, +/- 15%, 120 mA (with AC and DC supply)
Control Inputs
: 3 inputs, A, B, C (PNP/NPN/Namur)
Input currents
: 5.1 mA / 24 V (Ri = 4,7 kOhm)
Input level HTL
: Low: 0 ... 2 V, High: 9 ... 35 V
SSI input frequency range
: 100 Hz – 1 MHz
Min. pulse duration for Reset
: 5 msec
Analogue output (IX 346)
: 0/4 ... 20 mA (max. 300 ohms), 0...+/-10 V (max. 2 mA)
Resolution
: 14 Bits + Sign
Accuracy
: 0.1%
Serial interface (IX 348)
: RS 232 / RS 485, 600 to 38 400 bauds
Ambient temperature
: Operation: 0° - 45°C ( 32 – 113°F)
Storage: -25° - +70°C (-13 – 158°F)
Housing
: Norly UL94 – V-0
Display
: 6 decades, LED, high- efficiency orange, 15 mm (0.59’’)
Protection class
: Front IP65, Rear IP20
Terminal cross section
: Signals max. 1.5 mm², AC power max. 2.5 mm²
Switching outputs (IX 347)
: PNP, max. 35 volts, max. 150 mA
Conformity and Standards
: EMC 2004/108/EC:
EN 61000-6-2
EN 610 00-6-3
LV 2006/95/EC:
EN 61010-1
DA6-SSI/A-U