The subsequent example shows how to convert the display range from 1400 to 2000 into an
analogue signal of 2 - 10 volts.
2
4
6
8
10
1000
2000
3000
4000
5000
SSI Display Value
Volts
Analogue Output
A-ChAr = 0 - 10 V
AnAbEG
= 1400
OFFSEt = 2.000
AnAEnd
= 2000
GAin
= 8.00
All settings refer to the scaled values shown in the display of the unit,
and not to the original SSI encoder data