- 16 -
I/O’s signals and controls are only active when enabled through the software configurations.
Function
Terminal
block
Cable Harness
Wire
Pin
Description
Software configuration
DC voltage In
/Out
Right
Red wire
20
8-18vDC
Always present
Right
Black wire
6
GND/Common
Voltage out
Left
Red + White trace
19
+5vDC
Always present
Wiegand Out
Right
Green wire
10
Wiegand Out D0 /Output #7
Full Wiegand protocol is
available
Right
White wire
8
Wiegand Out D1 /Output #8
Left
Blue wire
4
Wiegand Common
Wiegand In
Left
Green + Black
trace
9
Wiegand In D0
Full Wiegand protocol is
available
Left
White + Black
trace
7
Wiegand In D1
Left
Blue wire
1
Wiegand Common
Door relay
Left
Yellow wire
18
Relay common
Right
White
trace
16
Door relay N/O
Normally open
Right
Black
trace
14
Door relay N/C
Normally closed
REX
Left
Pink wire
5
Remote door entry switch (REX)
Input #3
Door
Monitor
Left
Violet wire
3
Door monitor input
Input #4
Tamper
Right
Orange wire
12
Alarm Out (N/O)
Output #5 (see note)
RS485
Left
Black
trace
17
RS-485 –Ve (RS232-TX HWV1.0)
Baud rate, Node #
Left
White
trace
15
RS-485 +Ve
RS232
Left
Grey + Black
trace
13
RS-232 TXD
Baud rate, Node #
Left
Grey + White
trace
11
RS-232 RXD
0volts
Left +
Right
Blue
1
Common wire
Loop
Right
Not used
N/A
Isolated loop terminals.
Important Notice
Note: - Outputs # 5, 7 & 8 - Pulls Low (N/O) for 5-12V @40ma MAX