- 12 -
Physical Access Control
Where electronic door locks are to be controlled by the V30 Plus Finger Scanner the door lock wiring is
connected to the back of the V30 Plus Finger Scanner via the 20 way cable harness.
The V30 Plus can power door locking mechanisms that have a Maximum current draw of 150ma @12V. If you
are unsure please contact PeopleKey support for guidance.
Most door locks operate on 12V power, and a single “figure 8” wire pair is sufficient. Where a high voltage; high
power motorized door lock is required, or where other alarm equipment is used to power the door lock,
PeopleKey should be consulted to confirm the wiring requirement. Details for all connection options are listed in
the I/O table later in this manual.
Should customers require the monitoring of doors to report when the door is forced, opened or left ajar,
additional door switch detection wiring is required comprising of another pair of “figure 8” wire, Reed switch or
similar.
Important Note:
Refer to the
“V30 Plus relay use” guidelines as detailed within
Annex 1 of this document.
Door Relay
outputs
Door relay Normally Open contacts
Door relay Normally Closed contacts
REX
Remote door switch (REX)
Door Monitor
Door monitor input, N/C or N/O
Typically 90 m Maximum run length
Typically 500 m Maximum run length
PeopleKey finger
scanner
PeopleKey finger
scanner
Server or PC
RS232
RS485
RS485 to RS232 convertor
5: Finger scanner Serial, short runs
6: Finger scanner Serial, long runs