
Page 8
Standard Installation (Forward Flush only)
A standard installation clears the membrane periodically by opening a drain port, and allowing the feed stream
flow in its normal direction, but at a faster rate. The flow goes in and out of the end of the fiber instead of through
the membrane, and the foulant is cleaned off the membrane and out of the unit to drain.
Connect the FreshPoint™ to the household plumbing supply as shown in Figure 1. It is recommended that the
plumbing include a system bypass for future service. A 200 um sediment pre-filter is recommended. For ease of
membrane element replacement, unions are recommended as indicated on Figure 1.
NOTE: Installations without a pressure tank may experience drops in pressure/flow to the home during a
flush cycle.
Installation Instructions
Figure 1: Tankless Installation
Drain Flow Control
(Note Flow Direction)
Flow Meter Housing
(Note Flow Direction)
Drain
Piping Must
Include
Code-Compliant
Air Gap
1/4” Ball Valve Pressure Tap
for Membrane Integrity Testing
(Recommended)
Inlet Flow Control
(Note Flow Direction)
Pre-filter (Recommended)
Inlet Valve
Bypass Valve
Inlet
Outlet
Outlet Valve
42605_REVA
Содержание FreshPoint U440
Страница 1: ...FreshPoint U440 Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...
Страница 34: ...Page 34 Notes...
Страница 35: ...Page 35 Notes...
Страница 36: ...P N 42264 Rev B...