7-3
Changing the Atmospheric Pressure
The atmospheric pressure setting can be changed only when “Atmospheric
Correction” has been set to “ATM INPUT” in “Initial Setting 1”.
Example: Setting the pressure to 900 hPa
Press [F4] [CORR] in mode B.
(If the instrument is in mode A, press [F5]
[MODE] to enter mode B.)
Press [F4] [
h
] to move the cursor to
“4.PRESS” and press the [F5] [SELECT] to
enable the temperature to be changed.
Clear the exiting values by pressing [CLEAR]
key.
Input 900 by pressing the numeric keys.
50
7 CORRECTION MODE
SELECT
CORRECTION
1.PRISM CONST
0mm
2.SHEET CONST
0mm
3.TEMP
: +15
°
C
4.PRESS
: 1013hPa
5.ppm
0ppm
CORRECTION
1.PRISM CONST
0mm
2.SHEET CONST
0mm
3.TEMP
: +15
°
C
4.PRESS
: 1013hPa
5.ppm
0ppm
SELECT
CORRECTION
1.PRISM CONST
0mm
2.SHEET CONST
0mm
3.TEMP
: +15
°
C
4.PRESS
: 0900hPa
5.ppm
0ppm
CLEAR