7-2
Changing the Temperature
The temperature setting can be changed only when “Atmospheric Correction” has
been set to “ATM INPUT” in “Initial Setting 1”.
Example: Setting the temperature to +22°C
Press [F4] [CORR] in mode B.
(If the instrument is in mode A, press [F5]
[MODE] to enter mode B.)
Press [F4] [
h
] to move the cursor
to “3.TEMP” and press the [F5] [SELECT] to
enable the temperature to be changed.
Clear the exiting values by pressing [CLEAR]
key.
Input 22 by pressing the numeric keys.
48
7 CORRECTION MODE
SELECT
CORRECTION
1.PRISM CONST
0mm
2.SHEET CONST
0mm
3.TEMP
: +15
°
C
4.PRESS
: 1013hPa
5.ppm
0ppm
CORRECTION
1.PRISM CONST
0mm
2.SHEET CONST 0mm
3.TEMP
: +15
°
C
4.PRESS
: 1013hPa
5.ppm
0ppm
CLEAR
CORRECTION
1.PRISM CONST
0mm
2.SHEET CONST
0mm
3.TEMP
: +22
°
C
4.PRESS
: 1013hPa
5.ppm
0ppm
CLEAR
PENTAX R-300 (p20-52) 10/30/02 11:08 AM Page 48
Содержание R-315
Страница 66: ......
Страница 89: ...87 14 NOTICE TO THE USER OF THIS PRODUCT TARGET PLATE PENTAX R 300 p65 88 10 30 02 11 11 AM Page 87...
Страница 90: ...PENTAX R 300 p65 88 10 30 02 11 11 AM Page 88...