background image

DYNAPRO

®

 Self-Priming Pool/Spa Pump Installation and User’s Guide

P/N S771  Rev. E  7/19/18

If you have questions about ordering Pentair Aquatic Systems replacement parts, and pool products, please contact:

CUSTOMER SERVICE / TECHNICAL SUPPORT

Customer Service and Technical Support, USA

 

(8 A.M. to 4:30 P.M. — Eastern/Pacific Times)
Phone: (800) 831-7133
Fax: (800) 284-4151

Web site

Visit 

www.pentairpool.com

 or 

www.staritepool.com 

for 

information about Pentair products.

Sanford, North Carolina

 (8 A.M. to 4:30 P.M. ET)

Phone: (919) 566-8000
Fax: (919) 566-8920

Moorpark, California

 (8 A.M. to 4:30 P.M. PT)

Phone: (805) 553-5000 (Ext. 5591)
Fax: (805) 553-5515

TABLE OF CONTENTS 

Operation ...............................................................

Pressure Test
Priming the Pump
Draining the Pump
Winterizing
Start-up for Winterized Equipment

Maintenance ..........................................................

Cleaning the Strainer Basket
Pump Disassembly / Removing Old Seal
Pump Reassembly / Installing New Seal

Troubleshooting ....................................................
Replacement Parts ...............................................

Motor Table
Parts List

Important Pump Warning and 
Safety Instructions ................................................
Installation ..............................................................

Location
Piping

Taping Instructions
Fittings

Pump Suction Requirements

Suction Outlet Covers
Testing and Certification
Water Velocity

 

Electrical Installation

Wiring
Grounding
Bonding

ii
1

1
1
1
1
2
2
2
2
3
3
3
3

4

4
4
4
4
5

6

6
6
7

8
9

9
10

Pump Models

SINGLE SPEED MODELS

HP

MPRA Series

MPE Series

MPEA Series

1/2

MPE6C-204L

3/4

MPRA6D-204L

MPE6D-205L

MPEA6D-204L

1

MPRA6E-205L

MPE6E-206L

MPEA6E-205L

1-1/2

MPEA6F-206L

2

MPE6G-208L

MPEA6G-207L

2-1/2

MPEAA6G-208L

TWO SPEED MODELS

HP

MPRA Series

MPE Series

MPEA Series

1-1/2

MPRA6YF-206L

2

MPE6YG-208L

2-1/2

MPEAA6YG-208L

i

Содержание STA-RITE DYNA-PRO

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS DYNA PRO INSTALLATION AND USER S GUIDE SELF PRIMING POOL SPA PUMP...

Страница 2: ...Pump Draining the Pump Winterizing Start up for Winterized Equipment Maintenance Cleaning the Strainer Basket Pump Disassembly Removing Old Seal Pump Reassembly Installing New Seal Troubleshooting Rep...

Страница 3: ...GS AND ALL INSTRUCTIONS IN THE OWNER S MANUAL BEFORE USING THIS PUMP THESE WARNINGS AND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROM...

Страница 4: ...seriously injured by this high level of vacuum or may become trapped and drown It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes f...

Страница 5: ...To prevent flooding when removing the pump for service all flooded suction systems must have a gate valve in both the suction and discharge pipes 6 For most installations Pentair recommends installin...

Страница 6: ...running see Figure 2 However if two main drains run into a single suction line the single suction line may be equipped with a valve which will shut off both main drains from the pump see Figure 2 Mor...

Страница 7: ...entair salt chlorine generator Bonding 1 Bond the motor to the structure in accordance with the National Electrical Code and all other applicable national or local codes Use a solid copper bonding con...

Страница 8: ...port losing the prime and causing the pump to run dry resulting in a damaged seal Continued operation in this manner could cause a loss of pressure resulting in damage to the pump case impeller and se...

Страница 9: ...filter 3 Inspect all electrical wiring for damage or deterioration over the shutdown period Have a qualified serviceman repair wiring as needed 4 Inspect and tighten all watertight connections 5 Open...

Страница 10: ...ill not fit on the strainer pot 7 Clean and inspect the lid O Ring and reinstall on strainer groove 8 Clean the O Ring groove on the strainer pot and reinstall the lid locking ring Note To prevent sti...

Страница 11: ...the four 4 motor to seal plate screws Torque the screws to 60 80 inch lbs 69 92 kg cm 6 Apply a small amount of liquid detergent to the inside diameter of the rotating seal member 7 Slide the rotating...

Страница 12: ...impeller is not clogged Disassemble the pump according to Pump Disassembly on page 6 If a blockage in the impeller if found clear the blockage and reassemble the pump according to Pump Reassembly on p...

Страница 13: ...p adapter OR U11 199P 2 NPT adapter Box A Model No HP Motor Key No 1 Single Speed 115 230 60 1 MPRA6D 204L 3 4 A100DLL MPRA6E 205L 1 A100ELL MPRA6F 206L 1 1 2 A100FLL MPEA6D 204L 3 4 AE100DLL MPEA6E 2...

Страница 14: ...4 1 C8 58P C8 58P C8 58P C8 58P C8 58P 15A 2 U178 920P U178 920P U178 920P U178 920P U178 920P 15B 2 U30 919SS U30 919SS U30 919SS U30 919SS U30 919SS 16 1 C4 77P C4 77P C4 77P C4 77P C4 77P 17 1 C35...

Страница 15: ...NOTES...

Страница 16: ...and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Tho...

Отзывы: