Pentair STA-RITE DYNA-PRO Скачать руководство пользователя страница 10

6

 

DYNA-PRO

®

 Self-Priming Pool/Spa Pump Installation and User’s Guide

This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical 
Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious 
injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.

Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death 
or serious injury to serviceman, pool users or others due to electric shock.

Read all servicing instructions before working on the pump.

MAINTENANCE

Cleaning the Strainer Basket 

The only routine maintenance needed is inspection/
cleaning of the strainer basket. Debris or trash that collects 
in the basket will choke off water flow through the pump. 
Follow the instructions below to clean the strainer basket:
1.  Disconnect power to the pump at the circuit breaker.
2.  Close all gate valves in the suction and discharge lines.
3.  Release all pressure from the pump and piping system.
4.  Remove strainer lid (turn counter-clockwise). If 

necessary, tap handles gently with a rubber mallet.

5.  Remove the strainer basket and clean. Be sure all holes 

in basket are clear. 

6.  Flush basket with water and place back into the strainer 

pot.

 

Note:

 Ensure the large opening in the basket is 

oriented towards the pipe connection port (between ribs 
provided). If the basket is replaced backwards the lid 
will not fit on the strainer pot.

7.  Clean and inspect the lid O-Ring and reinstall on 

strainer groove.

8.  Clean the O-Ring groove on the strainer pot and 

reinstall the lid/locking ring. 

 

Note: 

To prevent sticking, hand tighten only.

9.  Prime the pump (see 

Priming the Pump, 

page 4).

Pump Disassembly / Removing Old Seal

1.  Disconnect power to the pump at the circuit breaker.
2.  Close all gate valves in the suction and discharge 

lines.

3.  Release all pressure from the pump and piping 

system.

4.  Drain the pump by removing the drain plug at the 

bottom of the strainer pot.

5.  Remove the six (6) nuts, lock-washers and flat 

washers holding the seal plate to the pump body. 

6.  Pull the seal plate and motor away from the pump 

body.

Note: 

A flathead screw driver can be used to carefully 

separate the body from the seal plate.

7.  Remove the seven (7) screws and washers securing 

the diffuser to the seal plate. Remove the diffuser.

8.  Carefully remove the motor canopy, being sure not to 

touch the capacitor terminals. Loosen the capacitor 
clamp and move it to one side.

9.  Hold the motor shaft with a 1/2” open-end wrench on 

the motor shaft flats.

10.  Unscrew the impeller from the motor shaft (turning 

counterclockwise when facing the impeller).
For 2 and 2.5 HP models, remove the impeller screw 
(left-hand thread) and gasket before removing the 
impeller. Inspect the gasket for damage or cracks and 
replace if damaged.

11.  Remove the rotating seal member from the motor 

shaft.

12.  Remove the four (4) screws securing the seal plate to 

the motor.

13.  Place seal plate face down on 

a flat surface and tap out white 
ceramic seal (see 

Figure 5

).

14.  Remove the slinger from motor 

shaft and inspect damage or 
abrasion.

15.  Clean the seal plate’s seal 

cavity and the motor shaft.

Figure 5

Alignment 

Arrows

Alignment 

Tab

Figure 4

Содержание STA-RITE DYNA-PRO

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS DYNA PRO INSTALLATION AND USER S GUIDE SELF PRIMING POOL SPA PUMP...

Страница 2: ...Pump Draining the Pump Winterizing Start up for Winterized Equipment Maintenance Cleaning the Strainer Basket Pump Disassembly Removing Old Seal Pump Reassembly Installing New Seal Troubleshooting Rep...

Страница 3: ...GS AND ALL INSTRUCTIONS IN THE OWNER S MANUAL BEFORE USING THIS PUMP THESE WARNINGS AND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROM...

Страница 4: ...seriously injured by this high level of vacuum or may become trapped and drown It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes f...

Страница 5: ...To prevent flooding when removing the pump for service all flooded suction systems must have a gate valve in both the suction and discharge pipes 6 For most installations Pentair recommends installin...

Страница 6: ...running see Figure 2 However if two main drains run into a single suction line the single suction line may be equipped with a valve which will shut off both main drains from the pump see Figure 2 Mor...

Страница 7: ...entair salt chlorine generator Bonding 1 Bond the motor to the structure in accordance with the National Electrical Code and all other applicable national or local codes Use a solid copper bonding con...

Страница 8: ...port losing the prime and causing the pump to run dry resulting in a damaged seal Continued operation in this manner could cause a loss of pressure resulting in damage to the pump case impeller and se...

Страница 9: ...filter 3 Inspect all electrical wiring for damage or deterioration over the shutdown period Have a qualified serviceman repair wiring as needed 4 Inspect and tighten all watertight connections 5 Open...

Страница 10: ...ill not fit on the strainer pot 7 Clean and inspect the lid O Ring and reinstall on strainer groove 8 Clean the O Ring groove on the strainer pot and reinstall the lid locking ring Note To prevent sti...

Страница 11: ...the four 4 motor to seal plate screws Torque the screws to 60 80 inch lbs 69 92 kg cm 6 Apply a small amount of liquid detergent to the inside diameter of the rotating seal member 7 Slide the rotating...

Страница 12: ...impeller is not clogged Disassemble the pump according to Pump Disassembly on page 6 If a blockage in the impeller if found clear the blockage and reassemble the pump according to Pump Reassembly on p...

Страница 13: ...p adapter OR U11 199P 2 NPT adapter Box A Model No HP Motor Key No 1 Single Speed 115 230 60 1 MPRA6D 204L 3 4 A100DLL MPRA6E 205L 1 A100ELL MPRA6F 206L 1 1 2 A100FLL MPEA6D 204L 3 4 AE100DLL MPEA6E 2...

Страница 14: ...4 1 C8 58P C8 58P C8 58P C8 58P C8 58P 15A 2 U178 920P U178 920P U178 920P U178 920P U178 920P 15B 2 U30 919SS U30 919SS U30 919SS U30 919SS U30 919SS 16 1 C4 77P C4 77P C4 77P C4 77P C4 77P 17 1 C35...

Страница 15: ...NOTES...

Страница 16: ...and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Tho...

Отзывы: