Low-ProfiLe end SeaL Kit inStaLLation inStructionS
THERMAL MANAGEMENT SOLUTIONS
EN-RaychemPMKGLE-IM-H54075 01/13
DEScRIpTION
The PMKG-LE is a NEMA Type 4X rated end seal kit designed for
use with Raychem BTV-CR, BTV-CT, QTVR-CT, LBTV2-CT, and
KHP-CR parallel heating cables. It is designed to be placed on the
pipe under the insulation and cladding.
For additional information contact your Pentair Thermal
Management representative or call (800) 545-6258.
TOOLS REqUIRED
• Screwdriver
• Wire cutters
• Utility knife
ADDITIONAL MATERIALS REqUIRED
• One grommet:
(1)
PMK-GK-10 P/N 222724-000 (Package of ten grommets)
• Glass cloth tape
– GT-66
Installation temperature above 40°F (4°C)
– GS-54
Installation temperature above –40°F ( –40°C)
(1)
Required for LBTV2 (see step 1)
This component is an electrical device that must be installed
correctly to ensure proper operation and to prevent shock or fire.
Read these important warnings and carefully follow all of the
installation instructions.
• To minimize the danger of fire from sustained electrical arcing
if the heat ing cable is damaged or improperly installed, and to
comply with the requirements of Pentair Thermal Management,
agency certifications, and National Electrical Codes, ground-
fault equipment protection must be used. Arcing may not be
stopped by conven tion al circuit breakers.
• Component approvals and performance are based on the use of
Pentair Thermal Management-specified parts only. Do not use
substitute parts or vinyl electrical tape.
• The black heating cable core is conductive and can short. It
must be properly insulated and kept dry.
• Damaged bus wires can overheat or short. Do not break bus wire
strands when scoring the jacket or core.
• Keep components and heating cable ends dry before and during
installation.
• Bus wires will short if they contact each other. Keep bus wires
separated.
• Use only fire-resistant insulation materials, such as fiberglass
wrap or flame-retardant foam.
WARNING:
KIT cONTENTS
Item qty Description
A
1
Pressure plate
B
1
End seal body with stainless steel screws
C
1
Red grommet (not for use with LBTV2)
D
1
End seal label
A
B
C
D
AppROvALS
-W
Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, Groups F, G
Class III
KHP-CR heating cables only
Hazardous Locations
Nonhazardous Locations
BTV-CR, BTV-CT, QTVR-CT and LBTV2-CT heating cables only