 Cartridge Style D.E. Filter Installation and User’s Guide

 

The following information describes how to install the 
Quad D.E.

®

 Cartridge Style Filter. Only a qualified 

service person should install this filter.

Note: Before installing this product, read and follow 
all warning notices and instructions on pages ii-iii.

Location

1.   The filter should be mounted on a level concrete 

slab. Position the filter so that instructions, 
warnings and the pressure gauge are visible to the 
operator. 

2.   Position the filter so that the piping connections, 

control valve and drain port are convenient and 
accessible for servicing and winterizing.

3.   Install electrical controls (e.g., on/off switches, 

timers, control systems, etc.) at least five (5) feet 
from the filter. This will allow you enough room to 
stand clear of the filter during system start up.

4.   Allow sufficient clearance around the filter to 

permit visual verification that the clamp is properly 
installed around the tank flanges, see 

Figure 1

.

 Note:

 Tap the clamp with a mallet or similar tool to 

ensure uniform loading during clamp tightening. 

5.   Allow sufficient space above the filter to remove 

the filter lid for cleaning and servicing. This 
distance will vary with the model of filter you 
are using. See 

Table 1

 for the required vertical 

clearance.

6.   Position the filter to safely direct water drainage. 

Rotate the High Flow™ Manual Air Relief Valve to 
safely direct purged air or water. Water discharged 
from an improperly positioned filter or valve can 
create an electrical hazard as well as damage 
property.

7.   Remove the plug from the top opening in the 

filter lid and install the manual air relief valve and 
pressure gauge before use.

Figure 1:

 Filter Installation Clearances

Table 1

 

 

            

Vertical

 

               Clearance     

Model 

       Size            Required      

QUAD 60         60 sq. ft.           62 in.          
QUAD 80         80 sq. ft.           68 in.         
QUAD 100       100 sq. ft.          74 in.

INSTALLATION

RISK OF ELECTRICAL SHOCK OR 
ELECTROCUTION.

Position the filter and High Flow manual air 
relief valve to safely direct water drainage and 
purged air or water. Water discharged from 
an improperly positioned filter or valve can 

create an electrical hazard that can cause severe personal injury 
as well as damage property. 

Plumbing

1.   Make all plumbing connections in accordance with 

local plumbing and building codes. Check local 
codes for restrictions on backwash to waste piping, 
separation tank requirements and spent D.E. 
disposal requirements.

2.    Filter plumbing connections are provided with an 

O-ring seal. To avoid damage to the O-rings, use 
only a silicone base lubricant on the O-rings. Do 
not use pipe joint compound, glue or solvent on the 
bulkhead connections.

3.   The filter requires one of the following Pentair 

accessories which must be purchased separately.

 

a.  P/N 261055 - 2” Multiport Valve Kit

 

b.  P/N 261173 - 1½” Multiport Valve Kit

 

c.  P/N 261050 - 2” HiFlow Valve Kit

 

d.  P/N 263064 - 2” PVC Slide Valve Kit

The Quad D.E. filter has a different water 
flow pattern than all other Pentair D.E. filters. 

When plumbing the filter with a backwash valve, one of the following 
valves, listed below, must be used. Failure to use the correct backwash 
valve could damage the filter elements and void the warranty.

Содержание QUAD 100

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE QUAD D E CARTRIDGE STYLE D E FILTER...

Страница 2: ...bing Operation General Filter Operation Clamp Installation System Restart System Restart Instructions Preparing Diatomite Coating the Filter Elements with D E TABLE OF CONTENTS ii 1 1 1 1 1 3 2 2 3 3...

Страница 3: ...t the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the pool equipment Failure to do so could result in serious injury or death to ser...

Страница 4: ...uring system start up shut down or servicing of the system filter IMPORTANT WARNING AND SAFETY INSTRUCTIONS QUAD D E Cartridge Style D E Filter Installation and User s Guide General Installation Infor...

Страница 5: ...t fiberglass reinforced polypropylene tank for exceptional strength and long life 2 plumbing connections for simple and secure maximum flow Conveniently located 2 drain for easy and efficient clean ou...

Страница 6: ...oned filter or valve can create an electrical hazard as well as damage property 7 Remove the plug from the top opening in the filter lid and install the manual air relief valve and pressure gauge befo...

Страница 7: ...This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 ps...

Страница 8: ...the nut as instructed above in Step 8 9 Continue on to System Restart Instructions on page 5 Note Check the spring coils at least once a month to ensure proper tension If spring coils do not touch tu...

Страница 9: ...the filter System Restart Instructions 1 Open the High Flow Manual Air Relief Valve until it snaps into the full open position this only requires a quarter turn counterclockwise Wait until valve relea...

Страница 10: ...Introduce the slurry of diatomite from the bucket directly into the top of the skimmer With the pump running and the pool skimmer valve open pour the mixture directly into the skimmer The slurry will...

Страница 11: ...inside and out 9 Lift bottom manifold out of the tank and flush off any debris 10 Direct water spray to wash out the inside of the tank body Water and debris will drain out through the open drain port...

Страница 12: ...alve rapidly releases air trapped in the filter 3 Stand clear of the filter tank then start the pump 4 Close the manual air relief valve after a steady stream of water appears 5 When water flows clear...

Страница 13: ...lement 6 Reinstall the elements and dispose of the acid solution in accordance with local regulations Failure to remove all oils and cleaning solutions from the filter elements before acid soaking wil...

Страница 14: ...nsert a 5 16 drill bit through the valve body to ensure the filter tank s air passage is open 5 Be sure the O rings are in good condition properly positioned and lubricated with a silicone base lubric...

Страница 15: ...immediately when a This is a characteristic of diatomite filters the filter starts SHORT FILTER RUNS Until the water initially put into the pool has been a Plaster dust can be responsible for short c...

Страница 16: ...E The pressure gauge is an important part of the a Check the operation of your pressure gauge IN GOOD WORKING ORDER filter system It is your primary indicator of how in the following manner the system...

Страница 17: ...DGE QUAD 60 7 170059 MANIFOLD ASSY BOTTOM QUAD DE 8 190003 CLAMP RPM FLT 9 39010200 O RING RPM TANK CLAMP 10 195339 RING BACKUP FNS PLS CNC PLS 11 196024S DIVERTER ASSY RETRO KIT 12 354571 O RING 200...

Страница 18: ...LITY AFTER CLEANABILITY Recommended Flow Rate Model Filter Area Sq Ft Vertical Clearance Flow Rate GPM Res Turnover Capacity Gallons Res Comm 6 hours 8 hours 12 hours Quad 60 60 62 120 150 43 200 57 6...

Страница 19: ...15 QUAD D E Cartridge Style D E Filter Installation and User s Guide NOTES...

Страница 20: ...A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Penta...

Отзывы: