background image

HAZARDOUS PRESSURE: STAND CLEAR OF 
PUMP AND FILTER DURING START UP

Circulation systems operate under high pressure. 
When any part of the circulating system (i.e. 
locking ring, pump, filter, valves, etc.) is serviced, 
air can enter the system and become pressurized. 

Pressurized air can cause the pump housing cover filter lid and valves 
to violently separate which can result in severe personal injury or death. 
Filter tank lid and strainer cover must be properly secured to prevent 
violent separation. Stand clear of all circulation system equipment when 
turning on or starting up pump.
Before servicing equipment, make note of the filter pressure. Be sure 
that all controls are set to ensure the system cannot inadvertently start 
during service. Turn off all power to the pump.

 

IMPORTANT: Place filter 

manual air relief valve in the open position and wait for all pressure 
in the system to be relieved. 

Before starting the system, fully open the manual air relief valve and place 
all system valves in the “open” position to allow water to flow freely from the 
tank and back to the tank. Stand clear of all equipment and start the pump.  

IMPORTANT: Do not close filter manual air relief valve until all 
pressure has been discharged from the valve and a steady stream 
of water appears. 

Observe filter pressure gauge and be sure it is not 

higher than the pre-service condition.

The following information should be read carefully 
since it outlines the proper manner of care and 

operation for your filter system.  As a result of following these instructions 
and taking the necessary preventative care, you can expect maximum 
efficiency and life from your filtration system.

For Installation of Electrical Controls at 
Equipment Pad (ON/OFF Switches, Timers and 
Automation Load Center)

Install all electrical controls at equipment pad, such 
as on/off switches, timers, and control systems, 
etc. to allow the operation (startup, shut-down, or 

servicing) of any pump or filter so the user does not place any portion of 
his/her body over or near the pump strainer lid, filter lid or valve closures.
This installation should allow the user enough space to stand clear of 
the filter and pump during system start-up, shut down or servicing of the 
system filter. 

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

QUAD D.E.

®

 Cartridge Style D.E. Filter Installation and User’s Guide

 

General Installation Information 

The following information should be read carefully since it outlines the 
proper manner of care and operation for your filter system. 
You can expect maximum efficiency and life from your filtration system by 
following these instructions and taking the necessary preventative care.
•  Have a trained pool professional perform all pressure tests.
•  Do not connect the system to a high pressure or city water system.
•  Trapped air in the system can create a hazardous condition. BE SURE 

to purge all air from the system before operating or testing equipment.

•  DO NOT pressure test with compressed air!
•  Piping must conform to local/state plumbing and sanitary codes.
•  Support piping independently to prevent strains on filter or valve.
•  Fittings restrict flow; for best efficiency, use the fewest possible fittings.
•  A check valve installed ahead of the filter inlet will prevent contaminants 

from draining back into the pool.

•  A check valve installed between the filter and heater will prevent hot water 

from backing up into the filter and deforming the internal components.

•  All wiring, grounding and bonding of associated equipment must meet 

local and/or National Electrical Code standards.

Only a qualified plumbing professional should install this filter. Refer to the 
“Important Warning and Safety Instructions on pages ii-iii for additional 
installation and safety information.

SERIOUS BODILY INJURY OR DEATH CAN 
RESULT IF THIS FILTER IS NOT INSTALLED AND 
USED CORRECTLY.
INSTALLERS, POOL OPERATORS AND POOL 
OWNERS MUST READ THESE WARNINGS AND 

ALL INSTRUCTIONS BEFORE USING THIS FILTER.

This filter is intended for use in swimming pool 
applications. Most states and local codes regulate the 

construction, installation, and operation of public pools and spas, and the 
construction of residential pools and spas. It is important to comply with 
these codes, many of which directly regulate the installation and use of this 
product. Consult your local building and health codes for more information.

SAVE THESE INSTRUCTIONS

IMPORTANT: 

Keep all warning labels in good condition. If any warnings 

labels are damaged, missing, or become illegible call Pentair Customer 
Service at 1-800-831-7133 and request replacement labeling.

iii

Содержание QUAD 100

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE QUAD D E CARTRIDGE STYLE D E FILTER...

Страница 2: ...bing Operation General Filter Operation Clamp Installation System Restart System Restart Instructions Preparing Diatomite Coating the Filter Elements with D E TABLE OF CONTENTS ii 1 1 1 1 1 3 2 2 3 3...

Страница 3: ...t the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the pool equipment Failure to do so could result in serious injury or death to ser...

Страница 4: ...uring system start up shut down or servicing of the system filter IMPORTANT WARNING AND SAFETY INSTRUCTIONS QUAD D E Cartridge Style D E Filter Installation and User s Guide General Installation Infor...

Страница 5: ...t fiberglass reinforced polypropylene tank for exceptional strength and long life 2 plumbing connections for simple and secure maximum flow Conveniently located 2 drain for easy and efficient clean ou...

Страница 6: ...oned filter or valve can create an electrical hazard as well as damage property 7 Remove the plug from the top opening in the filter lid and install the manual air relief valve and pressure gauge befo...

Страница 7: ...This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 ps...

Страница 8: ...the nut as instructed above in Step 8 9 Continue on to System Restart Instructions on page 5 Note Check the spring coils at least once a month to ensure proper tension If spring coils do not touch tu...

Страница 9: ...the filter System Restart Instructions 1 Open the High Flow Manual Air Relief Valve until it snaps into the full open position this only requires a quarter turn counterclockwise Wait until valve relea...

Страница 10: ...Introduce the slurry of diatomite from the bucket directly into the top of the skimmer With the pump running and the pool skimmer valve open pour the mixture directly into the skimmer The slurry will...

Страница 11: ...inside and out 9 Lift bottom manifold out of the tank and flush off any debris 10 Direct water spray to wash out the inside of the tank body Water and debris will drain out through the open drain port...

Страница 12: ...alve rapidly releases air trapped in the filter 3 Stand clear of the filter tank then start the pump 4 Close the manual air relief valve after a steady stream of water appears 5 When water flows clear...

Страница 13: ...lement 6 Reinstall the elements and dispose of the acid solution in accordance with local regulations Failure to remove all oils and cleaning solutions from the filter elements before acid soaking wil...

Страница 14: ...nsert a 5 16 drill bit through the valve body to ensure the filter tank s air passage is open 5 Be sure the O rings are in good condition properly positioned and lubricated with a silicone base lubric...

Страница 15: ...immediately when a This is a characteristic of diatomite filters the filter starts SHORT FILTER RUNS Until the water initially put into the pool has been a Plaster dust can be responsible for short c...

Страница 16: ...E The pressure gauge is an important part of the a Check the operation of your pressure gauge IN GOOD WORKING ORDER filter system It is your primary indicator of how in the following manner the system...

Страница 17: ...DGE QUAD 60 7 170059 MANIFOLD ASSY BOTTOM QUAD DE 8 190003 CLAMP RPM FLT 9 39010200 O RING RPM TANK CLAMP 10 195339 RING BACKUP FNS PLS CNC PLS 11 196024S DIVERTER ASSY RETRO KIT 12 354571 O RING 200...

Страница 18: ...LITY AFTER CLEANABILITY Recommended Flow Rate Model Filter Area Sq Ft Vertical Clearance Flow Rate GPM Res Turnover Capacity Gallons Res Comm 6 hours 8 hours 12 hours Quad 60 60 62 120 150 43 200 57 6...

Страница 19: ...15 QUAD D E Cartridge Style D E Filter Installation and User s Guide NOTES...

Страница 20: ...A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Penta...

Отзывы: