background image

Important Notice: 

This guide provides installation and operation instructions for 
this product. Consult Pentair with any questions regarding this 
equipment.
Attention Installer:

 

This guide contains important information about the 

installation, operation and safe use of this product. This information should 
be given to the owner and/or operator of this equipment after installation 
or left on or near the filter.

Attention User: 

This manual contains important information that will 

help you in operating and maintaining this filter. Please retain it for future 
reference.

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This is the safety alert symbol. When you see this symbol 

on your system or in this manual, look for one of the 

following signal words and be alert to the potential for 

personal injury.
Warns about hazards that can cause death, serious 

personal injury, or major property damage if ignored.
Warns about hazards that may cause death, serious 

personal injury, or major property damage if ignored.
Warns about hazards that may or can cause minor 

personal injury or property damage if ignored.

 NOTE

     Indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on 

equipment. Keep safety labels in good condition; replace if missing or 

damaged.

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

QUAD D.E.

®

 Cartridge Style D.E. Filter Installation and User’s Guide

Never exceed the maximum operating pressure of 
the system components. Exceeding these limits 
could result in a component failing under pressure. 
This instantaneous release of energy can cause the 
closure to separate and could cause severe personal 

injury or death if they were to strike a person.

Due to the potential risk that can be involved it is 
recommended that the pressure test be kept to 
the minimum time required by the local code. Do 
not allow people to work around the system when 
the circulation system is under pressure test. Post 

appropriate warning signs and establish a barrier around the pressurized 
equipment. If the equipment is located in an equipment room, lock the 
door and post a warning sign. 
Never attempt to adjust any closures or lids or attempt to remove or 
tighten bolts when the system is pressurized. These actions can result in 
a separation or failure of system components. This instantaneous release 
of energy can cause components to be accelerated to high velocities and 
to travel far distances. These components could cause severe personal 
injury or death if they were to strike a person.

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION

This filter must be installed by a qualified service 
professional in accordance with the National Electrical 
Code and all applicable local codes and ordinances. 
Always disconnect power to the equipment at the 

circuit breaker before servicing any of the equipment. Ensure that the 
disconnected circuit is locked out or properly tagged so that it cannot be 
switched on while you are working on the pool equipment. Failure to do 
so could result in serious injury or death to serviceman, pool users or 
others due to electric shock. 
Position the filter and the air relief valve to safely direct water drainage and 
purged air or water. Water discharged from an improperly positioned filter 
or valve can create an electrical hazard that can cause severe personal 
injury as well as damage property. 

Consumer Information and Safety 

This filter is designed and manufactured to provide many years of safe 
and reliable service when installed, operated and maintained according 
to the information in this manual and the installation codes referred to in 
later sections. Throughout the manual, safety warnings and cautions are 
identified by the “

” symbol. Be sure to read and comply with all of the 

warnings and cautions.

Before installing this product, read and follow all 
warning notices and instructions which are included. 

Failure to follow safety warnings and instructions can result in severe 
injury, death, or property damage.  Call (800) 831-7133 for additional free 
copies of these instructions. 

Do not operate the filter until you have read and 
understand clearly all the operating instructions and 

warning messages for all equipment that is a part of the pool circulating 
system. The following instructions are intended as a guide for initially 
operating the filter in a general pool installation, however each installation 
may have unique conditions where the starting procedure could be 
different. Failure to follow all operating instructions and warning messages 
can result in severe injury, death, or property damage.

To avoid this potential hazard, follow these instructions: 

1.  Before repositioning valve(s) and before beginning the assembly, 

disassembly, or adjustment of the clamp or any other service of the 
circulating system: (A) Turn the pump 

OFF

 and 

shut OFF 

any automatic 

controls to ensure the system is NOT inadvertently started during the 
servicing; (B) open the

 

manual air relief valve; (C) stand clear of the 

filter; (D) wait until all pressure is relieved.

2.   Whenever installing the filter clamp 

FOLLOW THE

 

FILTER CLAMP 

INSTALLATION INSTRUCTIONS EXACTLY

.

3.   Once service on the circulating system is complete 

FOLLOW SYSTEM 

RESTART INSTRUCTIONS EXACTLY

.

4.   Maintain circulation system properly. Replace worn or damaged parts 

immediately, (e.g., clamp, pressure gauge, valve(s), o-rings, etc).

5.   Be sure that the filter is properly mounted and positioned according 

to instructions provided.

FILTER OPERATES UNDER HIGH PRESSURE.

When any part of the circulating system, (e.g., clamp, 

pump, filter, valve(s), etc.), is serviced, air can enter 

the system and become pressurized. Pressurized 

air can cause the lid to separate which can result in 

severe injury, death, or property damage.

Do not permit children to use or operate this filter. 

Use only a PTFE or silicone based lubricant when 
lubricating the O-rings on the union and bulkhead 

couplings. Use of petroleum based products will damage the equipment.

ii

Содержание QUAD 100

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE QUAD D E CARTRIDGE STYLE D E FILTER...

Страница 2: ...bing Operation General Filter Operation Clamp Installation System Restart System Restart Instructions Preparing Diatomite Coating the Filter Elements with D E TABLE OF CONTENTS ii 1 1 1 1 1 3 2 2 3 3...

Страница 3: ...t the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the pool equipment Failure to do so could result in serious injury or death to ser...

Страница 4: ...uring system start up shut down or servicing of the system filter IMPORTANT WARNING AND SAFETY INSTRUCTIONS QUAD D E Cartridge Style D E Filter Installation and User s Guide General Installation Infor...

Страница 5: ...t fiberglass reinforced polypropylene tank for exceptional strength and long life 2 plumbing connections for simple and secure maximum flow Conveniently located 2 drain for easy and efficient clean ou...

Страница 6: ...oned filter or valve can create an electrical hazard as well as damage property 7 Remove the plug from the top opening in the filter lid and install the manual air relief valve and pressure gauge befo...

Страница 7: ...This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 ps...

Страница 8: ...the nut as instructed above in Step 8 9 Continue on to System Restart Instructions on page 5 Note Check the spring coils at least once a month to ensure proper tension If spring coils do not touch tu...

Страница 9: ...the filter System Restart Instructions 1 Open the High Flow Manual Air Relief Valve until it snaps into the full open position this only requires a quarter turn counterclockwise Wait until valve relea...

Страница 10: ...Introduce the slurry of diatomite from the bucket directly into the top of the skimmer With the pump running and the pool skimmer valve open pour the mixture directly into the skimmer The slurry will...

Страница 11: ...inside and out 9 Lift bottom manifold out of the tank and flush off any debris 10 Direct water spray to wash out the inside of the tank body Water and debris will drain out through the open drain port...

Страница 12: ...alve rapidly releases air trapped in the filter 3 Stand clear of the filter tank then start the pump 4 Close the manual air relief valve after a steady stream of water appears 5 When water flows clear...

Страница 13: ...lement 6 Reinstall the elements and dispose of the acid solution in accordance with local regulations Failure to remove all oils and cleaning solutions from the filter elements before acid soaking wil...

Страница 14: ...nsert a 5 16 drill bit through the valve body to ensure the filter tank s air passage is open 5 Be sure the O rings are in good condition properly positioned and lubricated with a silicone base lubric...

Страница 15: ...immediately when a This is a characteristic of diatomite filters the filter starts SHORT FILTER RUNS Until the water initially put into the pool has been a Plaster dust can be responsible for short c...

Страница 16: ...E The pressure gauge is an important part of the a Check the operation of your pressure gauge IN GOOD WORKING ORDER filter system It is your primary indicator of how in the following manner the system...

Страница 17: ...DGE QUAD 60 7 170059 MANIFOLD ASSY BOTTOM QUAD DE 8 190003 CLAMP RPM FLT 9 39010200 O RING RPM TANK CLAMP 10 195339 RING BACKUP FNS PLS CNC PLS 11 196024S DIVERTER ASSY RETRO KIT 12 354571 O RING 200...

Страница 18: ...LITY AFTER CLEANABILITY Recommended Flow Rate Model Filter Area Sq Ft Vertical Clearance Flow Rate GPM Res Turnover Capacity Gallons Res Comm 6 hours 8 hours 12 hours Quad 60 60 62 120 150 43 200 57 6...

Страница 19: ...15 QUAD D E Cartridge Style D E Filter Installation and User s Guide NOTES...

Страница 20: ...A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Penta...

Отзывы: