G-INSB-PROV (REV 12/2012)
3
SAFETY
WARNINGS
Prevent children from using the automatic backwash function.
Make sure the water level in the pool is sufficient when performing backwash
Disconnect power and relieve air pressure during installation and service on the valve.
Use a residual current Device (GFCI) compliant with local regulations with this device.
INTRODUCTION
Thank you for choosing the Pentair ProValve. This product will allow your pool control system to perform automated
backwash on your sand filter. The system is designed for the IntelliPool automation and monitoring system. Make sure
to have software version 4.14 or higher installed. Any other pool automation system having an output dedicated for
backwashing is also able to use the ProValve.
Make sure to read the important safety warnings and to make sure this manual is accessible to the users of this product.
Your ProValve is supplied with 63mm unions as well as unions matching the Triton filter. The ProValve is designed to
use compressed air (1.5 up to 3.5 bar) to activate the valve .
A 230V pilot valve as well as tubing is supplied with the filter.
On Triton filters supplied with the ProValve, the distance between the side holes on the filter match those of the ProV
-
alve. This distance is different on other Triton filters.
A specific adapter set (PROV-ADAP) for retrofitting the ProValve onto existing Triton filters is available.
FUNCTION
Figure 1 shows the function of the valve
The ProValve is a pneumatically operated valve with 2 functions.
1. In the ‘filter’ position pump flow is fed into the upper part of the filter . The filtered water is fed back into the pool.
2. When activated the valve has a ‘backwash’ function. In case of a power failure during the backwash operation, the
valve will return to the ‘filter position’.
It is recommended to stop the filter pump while the valve is changing position. When using an IntelliPool
system this is being done automatically.
INSTALLATION
Figure 2
shows the installation of the valve on a Triton filter.
Position A connects to the drain/waste
Position B connects to the pump outlet
Position C marks the return to the pool.
The assembly sketch includes the special adapters (PROV-ADAP) required when fitting the ProValve onto existing
Triton filters. These adapters (item D on
figure 2
) enable correct alignment of the valve connections onto the filter. Use
adhesive for hard PVC on the fittings and make sure to clean/degrease the fitting on beforehand. These adapters need
to be ordered separately.
Make sure to include the threaded collars when preparing the adhesive connections !
English
Содержание ProValve
Страница 1: ...G INSB PROV REV 12 2012 1 English ...
Страница 2: ...G INSB PROV REV 12 2012 2 ...
Страница 15: ...G INSB PROV REV 12 2012 15 A B C D Ø 63 mm E Ø 63 mm F FIGURES figure 1 figure 2 ...
Страница 16: ...G INSB PROV REV 12 2012 16 339 mm B C figure 3 figure 4 ...
Страница 17: ...G INSB PROV REV 12 2012 17 figure 5 figure 6 figure 7 figure 8 ...
Страница 18: ...G INSB PROV REV 12 2012 18 G INSB PROV 12 2012 18 figure 9 figure 10 figure 11 ...
Страница 19: ...G INSB PROV REV 12 2012 19 ...