DESCRIPTION

DESCRIPTION

Specifications/Ratings

 

Input Voltage........1-Phase 230VAC Nominal (190–265VAC)
Input Frequency....................................................50/60Hz
Ambient Temperate Range............................-20° to 50 °C
Output Connections........................3-Phase, 3-wire, 220V
.................................................................3-Wire/1-Phase 
..................................................................1-Phase/2-wire
Max Motor Cable Length...........................................305m
Enclosure.....................................................................3R 
 

Table 1 - Specifications 

Model

Max 

kW

Input 

Phase

Motor 

Operation

Max 

Amps

PID2000-

1123

1.5

1

2-wire, 3-wire 

& 3-phase

13.5

 

The PENTEK INTELLIDRIVE is specifically designed to 
operate 4” submersible pumps and 3-phase, 220V above 
ground pumps in water well and residential booster 
applications. Each Drive is rated for maximum output 
amp rating. Any use of Drive outside of intended design 
parameters will void warranty. If Drive is used with above 
ground motors not rated for a Variable Frequency Drive, 
maximize motor life by limiting lead length to 8m.  Refer 
to pump Owners Manual and AS/NZS 3000 for proper 
wire size.

Figure 1 - A typical residential installation layout

Each carton contains:

•  PENTEK INTELLIDRIVE Variable Frequency Drive
• Pressure Transducer
• 3m Pressure Transducer Cable
• Quick Start Guide 
• Owner’s Manual

PID2000 - 1          1          2          3

 

Product Family
PID

 - PENTEK INTELLIDRIVE

Voltage Rating:

1 = 190-265 Volt 1 phase input

Output voltage:

1 = 230v 1 phase output

HP Rating: 

Motor 

Type:  

 

2 = 2.0 HP

  

  

 3 = 3-wire

Transducer

 
The PENTEK 

 

INTELLIDRIVE uses a 4-20mA, 

0-668 kPa pressure transducer to control 
motor speed (max is 2068 kPa transducer).
The transducer (see Figure 1) senses 
pressure in the pipe and converts it to an 
electrical signal. The Drive senses and 
processes the signal in the PID (Proportional, 
Integration, Derivative) control. When 
operating in AUTOSTART mode, the Drive 
increases and decreases the speed of the 
pump motor as needed to maintain constant 
pressure in the piping system.

Keypad

 
The keypad programs the Drive, monitors the 
status of the pump, and displays faults if they 
occur. Each button has a unique function, as 
described in Figure 2. The LCD display shows 
a text display of the status of the Drive’s 
operation. Other LEDs light up to indicate 
when certain buttons are pressed or certain 
events occur.  

Fan

The Drive uses a thermostatically controlled 
internal fan which operates automatically 
when necessary to cool the Drive components.

Figure 2 - PENTEK INTELLIDRIVE keypad functions

6007 0412

Stops the 

motor.

Power is ON to Drive.

A fault has 

occurred.

Selects menu items and confirms 

numeric value changes.

Displays Drive’s current operating 

condition and changes display 

parameters.

Changes display to previous screen.

Drive is in Warning Mode (TPM); 

refer to Troubleshooting section.

Changes internal pressure setpoint 

from 103 kPa to transducer max 

-20 kPa . ie 2047kPa

Runs the Drive at 45Hz (with no 

pressure control) to allow installer 

to pump out well.*

Up and down arrows scroll through 
menus and change numeric values.

Toggles between English, 
Spanish, and French 
(default is English).

Resets fault that 
stopped Drive/pump.

With code, locks and 
unlocks password 
protected keys.

Left and right arrows move cursor.

Shows last 15 faults.

Checks for line fill, then starts pump 
in constant pressure mode.

Views and changes 
parameters.

PENTEK IntelliDrive

 Owner’s Manual

PENTEK IntelliDrive

 Owner’s Manual

5

4

Содержание PENTEK INTELLIDRIVE PID2000-1123

Страница 1: ...SSURE CONTROLLER Should the installer or owner be unfamiliar with the correct installation and or operation of this type of equipment please contact the distributor or manufacturer for the correct advice before proceeding with the installation or operation of this product ...

Страница 2: ...age 6 for circuit breaker sizing with no other appliances on the circuit Risk of burns The drive can become hot during normal operation Allow it to cool for 10 minutes after shut down before handling it to avoid burns Risk of electric shock A means for disconnection from the supply mains having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring...

Страница 3: ...gnal The Drive senses and processes the signal in the PID Proportional Integration Derivative control When operating in AUTOSTART mode the Drive increases and decreases the speed of the pump motor as needed to maintain constant pressure in the piping system Keypad The keypad programs the Drive monitors the status of the pump and displays faults if they occur Each button has a unique function as de...

Страница 4: ...984M 5 5 28 1 33 55 88 Mounting the Drive To mount the Drive as shown in Figure 6 follow this procedure 1 First remove the cover by backing out screw at bottom of front cover 2 Push on backplate with thumbs while pulling the cover toward you with index fingers creating a gap See Figures 3 and 4 3 Pull bottom of cover towards you lift up on cover and remove See Figure 5 Gap Figure 3 Separate cover ...

Страница 5: ...ly accepts 230V single phase input power If incoming power does not match this have a qualified electrician alter supply voltage to 230V 1Ph before connecting it to the Drive Terminal Removable pull down 01 01 I1 I1 I2 I2 V V AI AI P N SD CARD Transducer Cable Connections Submersible Motor 3 Ph 3 W 1 Ph follow colors as above Submersible Motor 1 Ph 2 W connect to Y and B any order Above Ground Mot...

Страница 6: ... installed before operating the PENTEK INTELLIDRIVE Most installations will only require the initial startup settings However the installer may need to set additional parameters Information about accessing all parameters explanations of their functions and procedures for changing parameter values will be found later in this section 1 Program the Drive Apply power to the PENTEK INTELLIDRIVE Setup G...

Страница 7: ...9 lists all available commands and parameters for the PENTEK INTELLIDRIVE 6569 0512 Press PSI Preset Use arrows to change the value Press Enter to Save Press Enter Figure 14 Change PSI Setpoint using PSI Preset 6568 0512 Press Auto Start Use arrows to change the value Press Enter to Save Press Enter Verify Running Fixed Press displayed on screen Figure 13 Change PSI Setpoint while running pump Key...

Страница 8: ...VALUE DESCRIPTION DEFAULT MIN MAX Ex Runtime Excessive Runtime Detection _ Enabled Disabled Enabled Enables or disables Excessive Runtime Detection Excessive Runtime Hours Hours 24 1 100 Number of hours Drive can run before it faults on Excessive Runtime Dry Run Auto Restart Delay Minutes 10 Min 3 Min 60 Min Time Drive waits to restart pump when Dry Run is detected Number of Resets 3 0 5 Number of...

Страница 9: ...and 8 Amps at up to 230VAC O1 Output relay dry contacts connection Programmed to close when pump is Running or Faulted Positive wires of an external device See Figures 17 and 18 P Positive connection of an RS 485 communication device see Figure 15 Positive wire from RS 485 device Per RS 485 Standard N Negative connection of an RS 485 communication device see Figure 15 Negative wire from RS 485 dev...

Страница 10: ...n Possible leak Check for pipe break or large leak Dry running pump Check water level in well Ground Fault Ground wire shorted to motor phase Check the ground wire for short to motor phase wire or check insulation integrity with a megger Long motor cable length If motor cable length is more than 305m a reactor or filter may be needed to limit capacitance between motor wires System Not Grounded Ung...

Страница 11: ... Fault Internal voltages are out of range Drive will auto reset and attempt to clear fault Fault Reset can be pressed to clear fault as well Then try to operate pump If fault continues Drive may need replacement Hardware Fault Internal hardware failure Fault Reset can be pressed to clear fault Then try to operate pump If fault continues Drive may need replacement External Fault The external device...

Страница 12: ...rial No Dealer Installer Installer Phone No Date of Installation Wire Lengths in Meters Circuit Breaker to Drive PENTEK INTELLIDRIVE to Motor Supply Voltage Note to Installer Record the data listed above for future reference Give manual to end user or attach to PENTEK INTELLIDRIVE when installation is complete OWNER S INFORMATION PENTEK IntelliDrive Owner s Manual 22 ...

Страница 13: ...yright law Any reproduction display publication modification or distribution is strictly prohibited without the prior written permission from Pentair Disclaimer Pentair reserves the right to change product specifications and products details All product images are for reference purposes only and may not represent actual and or current product 2022 Pentair All rights reserved ...

Отзывы: