Pentair MYERS K4563 Скачать руководство пользователя страница 8

STANDARD LIMITED WARRANTY

Myers

®

 warrants its products against defects in material and workmanship for a period of 12 months from the date 

of shipment from Myers or 18 months from the manufacturing date, whichever occurs first - provided that such 

products are used in compliance with the requirements of the Myers catalog and technical manuals for use in 

pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids. 

During the warranty period and subject to the conditions set forth, Myers, at its discretion, will repair or replace to 

the original user, the parts which prove defective in materials and workmanship. Myers reserves the right to change 

or improve its products or any portions thereof without being obligated to provide such a change or improvement 

for prior sold and/or shipped units.

Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start 

up through the Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m

Warranty is effective only if Myers authorized control panels are used. All seal fail and heat sensing devices must 

be hooked up, functional and monitored or this warranty will be void. Myers will only cover the lower seal and labor 

thereof for all dual seal pumps. Under no circumstance will Myers be responsible for the cost of field labor, travel 

expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an 

authorized Myers service facility.

This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or 

maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident 

or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units which 

are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is 

moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and 

manufactured; (g) to any unit which has been repaired or altered by anyone other than Myers or an authorized 

Myers service provider; (h) to any unit which has been repaired using non factory specified/OEM parts.

Warranty Exclusions: MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND BEYOND 

THE DESCRIPTION ON THE FACE HEREOF. MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES 

OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability Limitation: IN NO EVENT SHALL MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, 

INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY MYERS 

PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM 

IMPROPER INSTALLATION. MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS 

WARRANTY, FOR IMPROPER INSTALLATION. MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS.

Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental 

or consequential damages and therefore such limitations may not apply to you. No warranties or representations at 

any time made by any representatives of Myers shall vary or expand the provision hereof.

 

          

740 East 9th Street

Ashland, Ohio 44805-1969

419-289-1144

www.femyers.com

Warranty Rev 12/11

Содержание MYERS K4563

Страница 1: ...make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system STANDARD ELECTRICAL CONTROLS INSTALLATION AND SERVICE MANUAL Part K4563 2012 Pent...

Страница 2: ...get metal chips in the components while cutting hole After the hole is cut any metal particles must be removed from the box Failure to do so may result in premature component failure Connect incoming...

Страница 3: ...sure H O A switch is left in the Auto position after start up is completed Pump Start Up Refer to pump Installation and Service Manual PUMP MAINTENANCE WARNING Before handling these pumps and controls...

Страница 4: ...the HIGH WATER and the LAG OVERRIDE float position should be reversed SEAL FAILURE INPUTS Your pump may be equipped with a seal fail moisture sensor Refer to your pump owner s manual to determine if...

Страница 5: ...ugh to ac ti vate the floats 4 If there is enough water in the system with the power turned off mark and disconnect the off and on floats Next install jumper wires in the terminal blocks for off and o...

Страница 6: ...or solids 3 Possible motor failure fault in windings 4 Pump may be miswired to terminal block 5 Voltage and current unbalance Three phase only Voltage unbal ance on three phase power sources can cause...

Страница 7: ...i tor d The meter should in di cate low ohms when it is first connected but as the ca pac i tor becomes charged by the meter it will return to a reading of infinity open circuit 14 Start relay check a...

Страница 8: ...ions resulting from failure to properly install operate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal...

Отзывы: