12 V AC
~
230 V AC
~
2A
2A
PENTAIR INTERNATIONAL LLC,
Pentair International SARL
ELECTRICAL CONNECTION
Junction box
Transformer compliant with NF EN 61558-2-6
PHASE (L)
NEUTRAL (N)
Wire connectors
EXTERNAL SAFETY ISOLATION TRANSFORMER :
Using an external safety isolation transformer for multiple 12 VAC MicroBrite lights
When using multiple MicroBrite 12 VAC ~ lights on a 100 Watt safety isolation transformer, it is recommended
that no more than six (6) MicroBrite white lights be used.
For long cable lengths for each light, it is recommended not to exceed 45 m of total cable run between the
12 VAC isolation transformer and the MicroBrite.
Maximum wattage using multiple lights (with a 300 Watt isolation transformer).
IMPORTANT! When using multiple 12 VAC Pentair pool and spa lights the total allowable light wattage
should not exceed 80% of rated value.
The individual light wattage is as follows:
• One MicroBrite light is 12 Watts maximum
- Up to six (6) MicroBrite 12 V AC lights can be connected on a 100W transformer.
- Up to twenty (20) MicroBrite 12 V AC lights can be connected on a 300W transformer.
Ave. de Sévelin 20, CH-1004 - LAUSANNE, Switzerland
Copyright – Limited License: except as specifically permitted herein, no portion of the content on this document may be reproduced in any form or by any mean
without the prior written permission of Pentair International SRL.
6