manualshive.com logo in svg
background image

MagicFalls with LightCascade Technology LED Light Installation and User’s Guide

       

MagicFalls with LightCascade Technology LED Light Installation and User’s Guide

   

   III

 

              Most states and local codes regulate the construction, installation,  

 

 

and operation of public pools and spas, and the construction of 

residential pools and spas.  It is important to comply with these codes, many of which 
directly regulate the installation and use of this product. Consult your local building and 
health codes for more information.

SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS 
PRODUCT IS NOT INSTALLED AND USED CORRECTLY.
INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST 
READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE 
USING THIS PRODUCT. 

 

 

Before installing this product, read and follow all warning notices  

 

 

and instructions in this Guide. Failure to follow warnings and 

instructions can result in severe injury, death, or property damage.  
Call (800) 831-7133 for additional free copies of these instructions. Please refer to www.
pentair.com for more information related to this products.

IMPORTANT NOTICE 

- Attention Installer: 

This Installation and User’s 

Guide (“Guide”) contains important information about the installation, operation 
and safe use of this underwater light. This Guide should be given to the owner 
and/or operator of this equipment. 

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

Before working on or servicing lights, always disconnect 
power to the lights at the source circuit breaker from the 
light before servicing the light. Failure to do so could result 
in death or serious injury to service person,  pool users or 
others due to electric shock. When installing and using this 
electrical equipment, basic safety precautions should always 
be followed, include the following: 

This underwater light must be installed by a licensed or certified electrician or a 
qualified pool professional in accordance with the current National Electrical Code 
(NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable 
local installation codes and ordinances must also be adhered to. Improper 
installation will create an electrical hazard which could result in death or serious 
injury to pool users, installers or others due to electrical shock, and may also cause 
damage to power source. Always disconnect the power to the pool light at the 
circuit breaker before servicing the light. Failure to do so could result in death or 
serious injury to serviceman, pool users or others due to electrical shock. 

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION: 
UNDERWATER POOL LIGHTS REQUIRE HIGH VOLTAGE WHICH 
CAN SHOCK, BURN, OR CAUSE DEATH.

 

 

For countries in compliance with International Electrotechnical 

 

 

Commission (IEC) regulatory standards: 

The light fixture must 

be installed by a licensed or certified electrician or a qualified pool service person, in 
accordance with IEC 364-7-702 and all applicable local codes and ordinance. Improper 
installation will create an electrical hazard, which could result in death or serious injury 
to pool user, installer or other due to electrical shock and may also cause damage to the 
property.  

Содержание MAGICFALLS

Страница 1: ...ORFX Water Bowl Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS MAGICFALLS WITH LIGHTCASCADE TECHNOLOGY INSTALLATION AND USER S GUI...

Страница 2: ...for Multiple MagicFalls Water Effects 5 Maximum wattage when using multiple MagicFalls LED Lights and IntelliBrite Color LED lights using a 300 Watt Transformer 6 Powering On the MagicFalls LED Light...

Страница 3: ...e servicing the light Failure to do so could result in death or serious injury to service person pool users or others due to electric shock When installing and using this electrical equipment basic sa...

Страница 4: ...nterrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Powe...

Страница 5: ...OR GROUNDING WHEN POWERED BYALISTED 100 WATTOR 300 WATT 12 VAC TRANSFORMER AND INSTALLED IN COMPLIANCE WITH THE CURRENT NATIONAL ELECTRIC CODE NEC UNBONDED LIGHTING NEC PROVISIONS WHEN THE UL LISTED N...

Страница 6: ...pre programmed color light shows or select one of the five fixed colors to create virtually endless range of dramatic underwater lighting effects for a spectacular effect in your pool and spa If multi...

Страница 7: ...water port is a 1 1 2 in connection This allows installation of a standard 11 2 in diameter Sch40 fittings directly on the connection Waterfalls 5 and over have two 11 2 in bottom connections Note Th...

Страница 8: ...de Technology LED Light Installation and User s Guide 3 WATER FLOW REQUIREMENT CHART Use the Water Flow Requirement Chart below to determine the waterfall effect projection for 1 ft to 8 ft models WAT...

Страница 9: ...Cascade Technology LED Light Installation and User s Guide 4 WATERFALLS WATER EFFECT RADIUS CHART Use the Waterfall Radius Chart to determine the maximum radius cut available for a particular MagicFal...

Страница 10: ...fect Using Automation Control System MagicFalls Water Effect can also be automatically controlled via a Pentair Color Sync IntelliCenter IntelliTouch and EasyTouch Control Systems For more infor matio...

Страница 11: ...t and IntelliBrite LED light wattages are as follows One MagicFalls with LIghtCascade Technology Light is 14 Watts maximum One MicroBrite LED Pool light is 14 Watts maximum One FireFX LED Light is 25...

Страница 12: ...tch to activate a color light show or fixed color For details about saving color effects while in Show modes see Hold and Recall feature on Note Pentair Color LED lights can be controlled by Pentair A...

Страница 13: ...The next time the light is powered on the previously saved color show mode or fixed color will be displayed For example while in Party Mode switch the light off Wait more than 10 seconds switch the li...

Страница 14: ...e models and has an appropriately rated circuit breaker The conductors on the load side of the GFCI circuit shall not occupy conduit boxes or enclosures containing other conductors unless the addition...

Страница 15: ...waterfall is flowing into the pool spa or fountain The waterfall must be installed level or water will not flow out evenly from the spout Should water start to drip from the underside of the spillway...

Страница 16: ...DECK COVER IS 1 85 AND SHOULD BE TAKEN INTO ACCOUNT WHEN PLANNING WATERFALL LOCATION NOTE IF WATERFALL IS TO BE SET IN A RAISED WALL A 3 PVC PIPE EXTENSION MAY BE USED BETWEEN THE DECK LID COLLAR AND...

Страница 17: ...he bond beam as shown Figure 1 Attach a board to the side of the pool as shown Make sure this board is level The board will be used to set the level of the waterfall and create a form for the mortar b...

Страница 18: ...the waterfall ARE ABS MATERIAL AND THE LIGHT PORTS ARE PVC Use a pool industry standard brand of PVC cement for the PVC connections and ABS transition Glue green for the PVC to ABS connections Note C...

Страница 19: ...hing the Waterfall INSTALLING THE MAGICFALLS WITH LIGHTCASCADE TECHNOLOGY CONTINUED After the mortar bed is cured remove the board Be sure the lip protector is in place before installing the coping Ke...

Страница 20: ...t After the waterfall is completely installed remove the lip support Figure 4 Figure 4 Finishing the Waterfall If the waterfall does not produce a smooth sheet of water internal lip supports may be re...

Страница 21: ...tra cord Leave at least six 6 inches 15 2 cm of cord in the Junction Box or transformer to facilitate the light installation niche inspection Cut off any extra cord 7 Strip back three 3 inches of the...

Страница 22: ...properly and the niche is free of debris then reinstall install the light Note If the MagicFalls LED light assembly is not seated properly in the niche it will leak water down into the electrical cond...

Страница 23: ...ed or certified electrician or a qualified pool professional in accordance with the current National Electrical Code NEC NFPA 70 or the Canadian Electrical Code CEC CSA C22 1 and all applicable local...

Страница 24: ...ated wires be careful not to damage the insulation on the two 2 inner wires Strip back the two conductors Be careful not to damage the copper conductor 8 Connect both 2 wires to the corresponding circ...

Страница 25: ...e water from the waterfall In areas with deep freeze water must be drained from the waterfall and the water lines evacuated of water Once the water lines are drained remove the light engine from the m...

Страница 26: ...AMINARS 1 580101 White Deck Lid and Collar 1 580097 Tan Deck Lid and Collar 1 580105 Gray Deck Lid and Collar 1 580109 Dark Gray Deck Lid and Collar 1 580113 Black Deck Lid and Collar 2 580096 Light E...

Страница 27: ...ation and User s Guide 22 WATERFALL CONFIGURATION AND DIMENSION CHART C2 B C2 A C2 C2 B B C3 A 7 8 FT CONFIGURATION C2 B C2 B A 5 6 FT CONFIGURATION 4 FT CONFIGURATION A B C1 1 FT 3 FT CONFIGURATION A...

Страница 28: ...MagicFalls with LightCascade Technology LED Light Installation and User s Guide 23 NOTES...

Страница 29: ...Pentair trademarks and logos are property of Pentair or its global affiliates in the U S A and or other countries Third party registered and unregistered trademarks and logos are the property of thei...

Отзывы: