EASYLOGO 2-00 E
B 55002.11-2022.01
TECHNICAL DATA
Operating voltage
1/N/PE x 230V, 50 Hz
Power consumption
max. 2 W
Switching capacity
max. 2 x 800 W AC3 230 V
Minimum load per socket (built-in level control monitoring)
320 W
Control voltage
230 VAC / 12VDC
Potential-free contact
max. 5A / 250 VAC
Terminals
up to 2.5 mm²
One-site pre-fuse
16A
On-site residual current circuit breaker
≤ 30mA
Housing protection category
IP 54
Housing dimensions in mm
Height 152, width 202, depth 90
Weight
approx. 1.3 kg
Ambient temperature
-20° to 50°C
Air humidity
0 to 90% rH, with no condensation
Mains power connection
Plug the control unit into a properly installed socket only.
EMC
When our standard submersible pumps and accessories are installed as specified and used as intended, the control units meet the pro
-
tective requirements of the EMC Directive 2014/30/EC, and are suitable for domestic and commercial use when connected to the public
power supply network. If connected to an industrial power supply network within an industrial facility, where the power supply is provided
by an in-house high-voltage transformer, there may be insufficient immunity to interference.
Transport/storage
The control unit must be protected from the weather and stored in a dry place.
ENGLISH
13