GENERAL POINTS

- DANGER

 - INSTALLERS, POOL SPECIALISTS AND OWNERS MUST CAREFULLY READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING 

THIS PRODUCT.

- WARNING

 - Most countries regulate the construction, installation and operation of public swimming pools and spas, and the construction of residential pools and spas. It is important 

to comply with these regulations, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information

.

- CAUTION 

- This installation and user guide contains important information on the installation, operation and safety of this product. This guide should be provided to the owner 

and/or user of this product.

INSTALLATION

- DANGER

 - RISK OF ELECTRIC SHOCK or electrocution

- BEFORE WORKING ON THIS DEVICE - 

 Always cut the supply to the device at the circuit-breaker before maintenance. Failure to do this may lead to death or serious injury to 

service staff, pool users or others, due to an electric shock.

- DANGER

 - SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY.

- WARNING

 - Before installing this product, read and follow the warnings and instructions of this guide. Failing to follow these warnings and instructions may lead to serious 

injuries, death or material damage. Refer to www.pentairpooleurope.com for more information linked to this product.

- WARNING 

- Connect the device to a differential interrupter. If this system is used to control the underwater lighting devices, a differential interrupter must be installed upstream 

of these devices. Conductors downstream of the differential interrupter shall not occupy conduits, junction boxes or enclosures containing other conductors, except if the 
conductors are also protected by a differential interrupter. Refer to valid local codes for more details.

- WARNING

 - This product must be installed by an authorised or certified electrician or a qualified swimming pool professional. All of the applicable installation codes and local 

regulations must also be respected. Poor installation will create an electrical hazard which could result in serious injury or the death of pool users, installers or others due to 
electric shocks, and may also cause damage to property.

- DANGER

 - DISCONNECT THE SUPPLY CONNECTIONS BEFORE WORKING ON THIS DEVICE; ELECTRICAL POWER MAY BE SUPPLIED TO THE RELAY TERMINALS FROM OTHER SOURCES.

- CAUTION – CHEMICAL BURN HAZARD:

 Make sure all pumps are switched off at the main circuit breakers at the domestic distribution board before drilling into any pipes. Set 

rules for all handling related to electrical aspects, water and chemical products. Group the supply pumps and chemical product tanks in a safe and secured area.

- CAUTION -

 Do not use this product to control an automatic swimming pool cover. There is a risk that swimmers could become trapped under the cover.

- CAUTION

 – Devices which are not intended for use in single-family dwellings may require additional safety equipment to comply with local regulations.

- WARNING

 – Except for remote controls, install components at a minimum of at least 1.5 m (5 feet) from the inside wall of the pool or spa.

- WARNING

 - This product is intended for use in swimming pool applications only.

- CAUTION

 - A sufficient equipotential connection (min. 4.5 mm2 recommended), in accordance with local regulations, is obligatory for all metal components of the swimming 

pool, including the pool pump. This is necessary for the electrical safety as well as reduction of the corrosion risk.

IMPORTANT SAFETY GUIDELINES, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS

USE

- DANGER

 - DO NOT LET CHILDREN OPERATE THIS EQUIPMENT.

- CAUTION

 – Strictly respect the safety and handling procedures from the acid manufacturers, including protective measures for hands, body and eyes during transferring and 

using acid. Follow the prescribed safety precautions for handling muriatic acid intended for checking the water pH. Muriatic acid may cause serious physical harm and may 
damage the swimming pool equipment. Extra care must be taken when installing, maintaining and operating the acid pump feed systems. Acid is dangerous to handle and should 
be properly contained, transported, poured, stored and dispensed.

- CAUTION

 – Check the pH and sanitizer levels of the water before using the pool and make sure the filtration device is not obstructed.

- CAUTION

 – Periodically use an independent pH and chlorine testing kit to ensure that the pH and chlorine is at a safe level. If the pH and Oxidation Reduction Potential (ORP) or 

conductivity probes are broken, depleted or dirty with oils, lotions, or other contaminants, they can report inaccurate results to the system causing incorrect water chemistry, 
which could harm people or equipment.

- CAUTION

 – Consult the device display daily to ensure there are no alarm messages. 

- DANGER

 – Water temperatures greater than 37.7° C (100° F) are a health hazard. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the 

internal body temperature exceeds the normal temperature of 37° C (98.6 °F) by several degrees. Hyperthermia may produce the following effects: (1) Unawareness of impending 
danger. (2) Failure to perceive heat. (3) Failure to recognise the need to leave the spa. (4) Physical inability to leave the spa. (5) Harm to the foetus in pregnant women. (6) 
Unconsciousness leading to the risk of drowning. The use of alcohol, drugs or medicine is a factor which increases the risk of hypothermia in hot tubs and spas.

- WARNING

 - When mixing acid with water, ALWAYS ADD THE ACID TO THE WATER. Never add water to the acid. When adding a chemical product to the swimming pool, carefully 

follow the manufacturer instructions.

- DANGER -

 DO NOT MIX SODIUM HYPOCHLORITE AND MURIATIC ACID.

- DANGER 

- Keep standard solutions away from children, ensure that the bottles are securely closed, store them in a dry and ventilated location and do not let them freeze. The 

pH 4 calibration solution is acidic.

- DANGER 

- Batteries may contain dangerous substances. They should not be thrown into the bin, opened, thrown into fire or recharged, as there is a risk of explosion. Dispose of 

the batteries in accordance with the manufacturer instructions. There is a risk of explosion if the battery is replaced by an incorrect type of battery. Handle a leaking battery with 
gloves. Remove the batteries if the device is not used for an extended period of time.

- DANGER 

- The remote control contains a CR2032 button battery. Do not ingest the battery. In the case of ingestion, the battery or button accumulator may cause severe internal 

burns which can be fatal within just 2 hours. Store new and used batteries out of the reach of children. If the battery compartment does not close in a safe manner, stop using 
the product and keep it out of the reach of children. If you suspect that a battery has been ingested or introduced into any part of the body, seek a medical opinion immediately.

- DANGER 

- UV index information is supplied for information only and depends on the orientation and exposure of the radio relays.

For more information, we advise you to consult your dermatologist to inform you of the risks linked to your skin type.

Содержание IntelliPool

Страница 1: ...28 04 2017 15 23 48 Water temp 29 0 C pH 7 8 ORP 607mV Cond 5264uS 3 28g l INTELLI POOL INTELLIPOOL Water temperature pH ORP Conductivity P R O B E U N I T VALID ESC INTELLIPOOL C O N T R O L English...

Страница 2: ...tial codes is affixed to the first page of the cover This unique number ID key will be requested on creation of your free account at www intellipool eu An internet connection is required to access the...

Страница 3: ...te the life of your pool and the INTELLIPOOL Control Center will automatically regulate your pool and permit you to control it remotely via the internet relay Please carefully read this user manual to...

Страница 4: ...l as reduction of the corrosion risk IMPORTANT SAFETY GUIDELINES READ AND FOLLOW ALL OF THE INSTRUCTIONS KEEP THESE INSTRUCTIONS USE DANGER DO NOT LET CHILDREN OPERATE THIS EQUIPMENT CAUTION Strictly...

Страница 5: ...l Center menus Create an account at www IntelliPool eu USE www intellipool eu menus Reading messages on the indoor display OPTIONS MAINTENANCE Adding a second radio relay Re programming the original i...

Страница 6: ...urs Auxiliary outlet Automatic backwash with push pull valve accessory function with a second pump or a 3 way valve ON OFF mode clock All these characteristics can be accessed directly from IntelliPoo...

Страница 7: ...feature to be activated in terms of pool aspects The RADIO RELAY assures radio communications between the elements while collecting the temperature of the ambient air In this configuration the system...

Страница 8: ...your installation 2 Power the internet relay by connecting it only to the supplied mains supply The internet relay is automatically configured provided the DHCP server of your internet box is activate...

Страница 9: ...Pentair ref XXX install the pH RedOx and Conductivity probes in accordance with the diagram below The glass conductivity probe uses the gasket and the O ring to ensure a perfect seal The ORP and pH p...

Страница 10: ...bypass in front of the filter of the pump or in front of the filter inlet in order to improve the reading precision 1 Pierce the PVC pipe to a diameter of 10 mm 3 8 inch 2 Remove the shavings and chec...

Страница 11: ...2 Buttons navigation menu 4 Fuse holder 1 A 5 Connector cover can be unclipped with a screwdriver 6 Screw cover protection against entry of vapours 7 Rubber cover Watertight protection 8 Radio antenn...

Страница 12: ...ical device If necessary place overvoltage protection equipment before the device The device must be placed close to the electrical cabinet to aid connections 3 m max Hygiene of Control Center electri...

Страница 13: ...ion and Probe Unit on the Control Center Connections from the Probe Unit to the Control Center and from the pool cover The Control Center must be placed close to the electrical cabinet to aid connecti...

Страница 14: ...ne injection must be placed after filtration after the heat pump and after the probes 1 Connect the 230 V 2 Connect the IntelliFlo ref 350122 15 m cable supplied with IntelliPool 3 Connect the green c...

Страница 15: ...tic backwash to the Control Center 1 Connect the 3 way valve as described below Connection of a 3 way valve to the Control Center 1 Connect a second pump to the AUX1 outlet as described below Connecti...

Страница 16: ...Center 1 Connect the lighting in accordance with the power as described below Connection of the lighting to the Control Center Total power of lighting is lower than 1 600 W Total power of lighting exc...

Страница 17: ...ewed to a wall The battery autonomy is around 1 year If there is a large distance or a garden with a great deal of elevation one or several radio relays can be added see p33 1 Wall clip fixing holes 2...

Страница 18: ...fence zinc gutter and must not be directly exposed to the sun to ensure reliable measurement of the air temperature Perform tests read the radio signal strength on screen move the CALIB switch at the...

Страница 19: ...nt Units language and F C selection Time Radio Register equipment Register remote control Reset remote control Menu Lighting Manual Program Off Colour 0 Schedule settings Filtration menu Auto On Off P...

Страница 20: ...ure below which the disinfectant is not injected or the electrolyser is stopped to the limit wear of the plates Volume days Max Maximum authorised volume of disinfectant for a flow pump of 1 L h to sa...

Страница 21: ...pm Optimum 1 234 rpm IntelliChlor Production 74 CURRENT DAY ACTIVITY Filtration 14H07m Aux1 00H01m Lighting 04H23m CURRENT DAY ACTIVITY Conductivity 5664uS CURRENT DAY ACTIVITY Heating 00H00m pH corre...

Страница 22: ...e value may launch filtration even if this is in the non execution period Lighting filtration AUX1 menus 07 12 2013 15 23 48 Water temp 29 0 C pH 7 8 ORP 607mV Cond 5626uS 3 51g l Menu Settings Menu L...

Страница 23: ...le languages are English German Dutch French Spanish and Italian English Menu Settings Menu Lighting Menu Filtration Menu Aux1 SETTINGS MENU pH Disinfect Temp Language Time Radio CONTROLS pH Disinfect...

Страница 24: ...volume menu factory setting 0 5 L day Check the level of pH corrector in the tank Calibrate the pH probe The filter must be cleaned Perform backwashing pH corrector tank empty Fill the tank with pH c...

Страница 25: ...l Center It is a five digit number Do not use the serial number of the internet relay or the indoor display 5 2 ID Key This is a unique security code which certifies the device It is on the same label...

Страница 26: ...een used by many visitors The summary menu is the main menu It is a dashboard which displays all the parameters of the current situation The command menu is used to launch a piece of equipment or to s...

Страница 27: ...account The display depends on the type of equipment connected and the options selected Set point menu Set the Control Center to the time of the computer These schedule settings are only used if the f...

Страница 28: ...to change the speeds on your IntelliFlo pump IntelliFlo VF clients need to use the ste speed button Minimum speed Find the minimum speed which is capable of generating sufficient flows in the pool In...

Страница 29: ...eset Save modifications English These two menus make it possible to configure different alarms which may differ from the indoor display alarms The alarm values also determine the display of the ticks...

Страница 30: ...many situations this tool will permit a professional to resolve problems without needing to visit the site The data is available for 10 years Adjustment of graph scale Analysis of data by day month y...

Страница 31: ...liFlo running 11 Alarm mode 12 Calibration mode 13 Radio mode 14 Acoustic alarm ON 15 Acoustic alarm OFF 16 IntelliFlo alert 17 IntelliChlor alert 18 N A 19 Filter cleaning requested 20 Indoor display...

Страница 32: ...37 4 F Temperatures Detection of risk of snow The display is intended for internal use Do not expose to sun or rain Exposure to sunlight UV or rain may cause irreversible damage BATTERY CAP TRIPOD RE...

Страница 33: ...is at low batteries the batteries should be changed The radio range of the IntelliPool network depends on the geographical installation of the radio relay and the indoor display a long distance a pool...

Страница 34: ...he S value reveals the age of your pool s water The conductivity unit S or g l is selected by the calibration mode unit change see p34 If the display uses S as a measurement unit and the value exceeds...

Страница 35: ...ntration of the hydrogen ions For a swimming pool the ideal pH which is generally advised is close to 7 3 to be confirmed by your swimming pool supplier according to your installation The precision of...

Страница 36: ...es as the original display Replace the battery hatch Note If the original remote display alarm values have been adapted they must be manually re modified in the new display to be identical Re learning...

Страница 37: ...y The values are saved when the batteries are changed 2 Follow the procedure 3 When the modifications are approved put the switch back in ON mode To restore all the factory values of the device push a...

Страница 38: ...ut the switch in Calib mode on the back of the indoor display 2 Follow the procedure 3 When the modifications are approved put the switch back in ON mode 1 Escape Goes back to the previous step withou...

Страница 39: ...emperature this procedure needs to be performed in the shade 25 C 77 F 1 Put the switch in Calib mode on the back of the indoor display 2 Follow the procedure 3 Dip the end of the pH probe into the pH...

Страница 40: ...be performed in the shade 25 C 77 F 1 Put the switch in Calib mode on the back of the indoor display 2 Follow the procedure 3 Dip the end of the RedOx probe in the 240 mV calibration solution bottle f...

Страница 41: ...ion of the read values 45000 Next Choose Choose Conductivity pH Probe Initialisation Settings Correction Result Correction of the read values 45000 Next Previous Probe Initialisation Settings Correcti...

Страница 42: ...r of the USB stick formatted to FAT 16 or FAT 32 2 1 Remove the flexible blue cover of the Control Center and the Probe Unit 2 2 Cut the supply of the Control Center via the 1 A 230 V fuse using a fla...

Страница 43: ...de The menu texts evolve as the functions change Updating the internal text file makes full use of the functions possible 3 Loading of the latest menu texts 1 3 1 4 2 1 Press Press the Up button 2 5 R...

Страница 44: ...the pH probe Rinse the end of the probe for 5 minutes generously under running water Protective glasses and gloves must be worn for these cleaning operations Since the radio relay is placed outside th...

Страница 45: ...44 The original spare parts required to maintain your Pentair device are available from your dealer USE OF PARTS OTHER THAN GENIUS PENTAIR PARTS INVALIDATES THE WARRANTY Spare parts...

Страница 46: ...1004 LAUSANNE Switzerland Copyright Limited licence except as specifically permitted herein no portion of the content of this document may be reproduced in any form or by any means without the prior...

Отзывы: