background image

INTELLIFLO

XF

®

 

and INTELLIPRO

XF

®

  

Variable Speed Pump Installation and User’s Guide

IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS 

 

When installing and using this electrical equipment, basic safety 

precautions should always be followed, include the following:

Do not permit children to use this product.

RISK OF ELECTRICAL SHOCK. Connect only to 

a branch circuit protected by a ground-fault circuit-

interrupter (GFCI). Contact a qualified electrician if you cannot verify that 

the circuit is protected by a GFCI. 

This unit must be connected only to a supply circuit 

that is protected by a ground-fault circuit-interrupter 

(GFCI). Such a GFCI should be provided by the installer and should 

be tested on a  routine basis. To test the GFCI, push the test button. 

The GFCI should interrupt power. Push the reset button. Power should 

be restored.  If the GFCI fails to operate in this manner, the GFCI is  

defective. If the GFCI interrupts power to the pump without the test button 

being pushed, a ground current is flowing, indicating the possibility of an 

electric shock. Do not use this pump. Disconnect the pump and have the 

problem corrected by a qualified service representative before using.

This pump is for use with permanent swimming 

pools and may also be used with hot tubs and spas if 

so marked. Do not use with storable pools. A permanently-installed pool 

is constructed in or on the ground or in a building such that it cannot be 

readily disassembled for storage. A storable pool is constructed so that 

it is capable of being readily disassembled for storage and reassembled 

to its original integrity.

General Warnings
•  Never  open  the  inside  of  the  drive  motor  enclosure.  There  is  a 

capacitor bank that holds a 230 VAC charge even when there is no 

power to the unit.

•  The pump is not submersible.

•  The pump is capable of high flow rates; use caution when installing 

and programming to limit pumps performance potential with old or 

questionable equipment.

•  Code requirements for the electrical connection differ from state to 

state. Install equipment in accordance with the National Electrical 

Code and all applicable local codes and ordinances.

•  Before  servicing  the  pump;  switch  OFF  power  to  the  pump  by 

disconnecting the main circuit to the pump.

•  This appliance is not intended for use by persons (including children) of 

reduced physical, sensory or mental capabilities, or lack of experience 

and knowledge, unless they have been given supervision or instruction 

concerning the use of the appliance by a person responsible for their 

safety.

FAILURE TO FOLLOW ALL INSTRUCTIONS AND 

WARNINGS CAN RESULT IN SERIOUS BODILY 

INJURY OR DEATH. 

THIS PUMP SHOULD BE INSTALLED AND 

SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. 

INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE 

WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S MANUAL 

BEFORE USING THIS PUMP. THESE WARNINGS AND THE OWNER’S 

MANUAL MUST BE LEFT WITH THE POOL OWNER.

SUCTION  ENTRAPMENT  HAZARD:  STAY  OFF 

THE MAIN DRAIN AND AWAY FROM ALL SUCTION 

OUTLETS!

THE  USE  OF  UNAPPROVED  COVERS  OR ALLOWING  USE  OF 

THE POOL OR SPA WHEN COVERS ARE MISSING, CRACKED OR 

BROKEN  CAN  RESULT  IN  BODY  OR  LIMB  ENTRAPMENT,  HAIR 

ENTANGLEMENT,  BODY  ENTRAPMENT,  EVISCERATION AND/OR 

DEATH.  
The suction at a drain or outlet can cause:
Limb Entrapment:  When a limb is sucked or inserted into an opening 

resulting in a mechanical bind or swelling. This hazard is present when 

a drain cover is missing, broken, loose, cracked or not properly secured.
Hair Entanglement:

 

When the hair tangles or knots in the drain cover, 

trapping the swimmer underwater.  This hazard is present when the flow 

rating of the cover is too small for the pump or pumps.
Body Entrapment: When a portion of the body is held against the drain 

cover trapping the swimmer underwater.  This hazard is present when the 

drain cover is missing, broken or the cover flow rating is not high enough 

for the pump or pumps.
Evisceration/Disembowelment:

 

When a person sits on an open pool 

(particularly a child wading pool) or spa outlet and suction is applied directly 

to the intestines, causing severe intestinal damage.  This hazard is present 

when the drain cover is missing, loose, cracked, or not properly secured.

THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES 

A STRONG VACUUM AT THE MAIN DRAIN AT THE BOTTOM OF THE 

BODY OF WATER. THIS SUCTION IS SO STRONG THAT IT CAN TRAP 

ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE 

PROXIMITY TO A DRAIN OR A LOOSE OR BROKEN DRAIN COVER 

OR GRATE.

This guide provides installation and operation instructions for the 

IntelliFloXF

®

 

and IntelliProXF

®

 

 

Variable Speed Pumps. Consult Pentair 

with any questions regarding this equipment. 

Attention Installer: This guide contains important information about the 

installation, operation and safe use of this product. This information should 

be given to the owner and/or operator of this equipment after installation 

or left on or near the pump. 

Attention User: This manual contains important information that will help 

you in operating and maintaining this product. Please retain it for future 

reference.

This is the safety alert symbol. When you see this 

symbol on your system or in this manual, look for 

one of the following signal words and be alert to 

the potential for personal injury.
Warns about hazards that can cause death, 

serious personal injury, or major property damage 

if ignored.
Warns about hazards that may cause death, 

serious personal injury, or major property damage 

if ignored.
Warns about hazards that may or can cause 

minor personal injury or property damage 

if ignored.

NOTE  indicates special instructions not related to hazards.
Carefully read and follow all safety instructions in this manual and on 

equipment. Keep safety labels in good condition; replace if missing 

or damaged.

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPORTANT NOTICE

F

Содержание IntelliFloXF

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP...

Страница 2: ...peed Pump Operating Modes Control Panel Language Operator Control Panel Menu Guide Pump Settings Pump Address Set Time AM PM or 24 Hour Clock Set Temperature Unit Screen Contrast Level Set Min Max Spe...

Страница 3: ...NUAL BEFORE USING THIS PUMP THESE WARNINGSAND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROMALLSUCTION OUTLETS THE USE OF UNAPPROVED C...

Страница 4: ...f suction can pose a risk if a person comes within the close proximity of the suction openings A person can be seriously injured by this high level of vacuum or may become trapped and drown It is abso...

Страница 5: ...ll the retainer ring with the tab features pointing away from the nut Union Adapter Installation Installing the locking union onto the pump 1 Glue the PVC union adapter fitting to the PVC pipe The ada...

Страница 6: ...ump prime faster and last longer Fittings and Valves 1 Do not install 90 elbows directly into pump inlet 2 Flooded suction systems should have gate valves installed on suction and discharge pipes for...

Страница 7: ...ntlyconnectedtoeither a circuit breaker 2 pole timer or 2 pole relay If AC power is supplied by a GFCI circuit breaker use a dedicated circuit breaker that has no other electrical loads 10 IMPORTANT W...

Страница 8: ...or after servicing DO NOT run the pump dry If the pump is run dry the mechanical seal will be damaged and the pump will start leaking If this occurs the damaged seal must be replaced ALWAYS maintain...

Страница 9: ...ls and LEDs on Key Pad Quick Clean Pump ramps up to higher RPM for vacuuming cleaning adding chemicals and after a storm for extra skimmer power LED light is on when active Time Out Pump is not runnin...

Страница 10: ...Speeds 1 4 can be programmed in all three modes Speeds 5 8 can only be programmed in Schedule mode since there are no buttons on the control panel for Speeds 5 8 The default setting for Speeds 5 8 is...

Страница 11: ...ion 1 min to 10 hrs Default 3 hours 1 min to 30 min Default 11 minutes Disabled Enabled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Sta...

Страница 12: ...ess 4 To change the pump address press Select 5 Press Up or Down arrows to change the address number from 1 16 6 Press Enter to save To cancel any changes press Escape to exit without saving 7 Press E...

Страница 13: ...on of four 4 digits Password protection can always be turned off by pressing Start Stop Password protection cannot be turned back on with Start Stop while running in manual mode Pressing Start Stop wh...

Страница 14: ...is means the IntelliFloXF Variable Speed Pump will go into Password Protection mode 10 minutes after the last control panel key is pressed 8 Press Select to change time setting from 1 minute to 6 hour...

Страница 15: ...o display Time 8 Press Select and use arrow keys to adjust time 9 Press Enter to save the new time setting 10 Press Escape to exit Manual Assigns a speed to one of the four Speed buttons on the contro...

Страница 16: ...displayed Note The pump will not run the scheduled speeds until the Start Stop button is pressed LED on to place the pump in Schedule mode Note When two speeds are scheduled during the same run time...

Страница 17: ...will be lit and ready to turn on at the next scheduled run time To access the Time Out menu 1 Check that the green power LED is on 2 Press Menu 3 Use Up or Down arrows to scroll to Features then pres...

Страница 18: ...er and restart the pump Default 20 seconds Priming delay can be set from 1 second to 10 minutes If the pump does not have enough water after the automatic priming mode the pump will ramp to the Maximu...

Страница 19: ...ck to page 14 for instructions on accessing the priming menu and features 1 Disable priming on automation control system 2 Disconnect the RS 485 communication cable To disable priming with an automati...

Страница 20: ...4 The factory default for Anti Freeze is Enabled To disable Anti Freeze press Select to highlight Enabled 5 Press the Up arrow Disabled is displayed 6 Press Enter to save To Set Anti Freeze Speed and...

Страница 21: ...r 15 100 VDC 1 mA 1 Input 50 60 Hz 5 6 Program 2 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 7 8 Program 3 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 9 10 Program 4 15 240 VAC or 15 100 VDC 1 m...

Страница 22: ...o the COM port screw terminals 2 and 3 Be sure to match the color coding of the wires YELLOW to YELLOW and GREEN to GREEN The Red wire is not connected Secure the wires with the screws IntelliTouch CO...

Страница 23: ...oltage raceway to the motherboard Connecting the Pump to a SunTouch Control System 4 Strip back the cable conductors 6 mm 1 4 Insert the wires into the screw terminals provided Secure the wires with t...

Страница 24: ...hout water in the strainer pot Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water Opening the pump may cause serious personal injury I...

Страница 25: ...s ventilation Protect against dirt 1 Protect from any foreign matter 2 Do not store or spill chemicals on or near the motor 3 Avoid sweeping or stirring up dust near the motor while it is operating 4...

Страница 26: ...ith water 11 Reinstall the pump lid and locking ring see Cleaning the Pump Strainer Basket on page 20 12 Prime the system See page 4 for priming instructions Drive Assembly Removal and Installation To...

Страница 27: ...rm or warning is acknowledged with the Enter button Press the Reset button to clear the alarm once the fault condition has been resolved Note The pump will not start if the impeller is rotating Power...

Страница 28: ...ti spin bolt and o ring 3 Remove clean and reinstall impeller 4 Reinstall anti spin bolt and o ring Reinstall diffuser and o ring Reinstall motor and seal plate into volute Reinstall clamp band around...

Страница 29: ...is open Motor runs too hot Turn power to motor off Check for proper voltage Check for proper impeller or impeller rubbing Mechanical Troubles and Noise The pump motor is running but with loud noise F...

Страница 30: ...Washer U43 12SS 17 Flat Washer 072184 18 Diffuser O Ring 350336 REPLACEMENT PARTS Item No Description IntelliFloXF IntelliProXF 19 Diffuser Screw 353323 20 Diffuser 400010 21 Impeller Reverse Screw 3...

Страница 31: ...mic Head in Ft of H2O Speed 1 750 rpm Speed 2 1560 rpm Speed 3 2350 rpm Speed 4 3110 rpm Max Speed 3450 rpm Pump Dimensions ANCHOR BOLT MOUNTING LOCATIONS 298 mm 11 7 in 232 mm 9 125 in 166 mm 6 5 in...

Страница 32: ...abled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Start Time Set Stop Time Disabled Default Disabled Default Enabled 1 100 Default 1 1...

Страница 33: ...NOTES...

Страница 34: ...NOTES...

Страница 35: ...NOTES...

Страница 36: ...nless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentai...