If restarting the pump after service or maintenance, please follow the priming instructions on page 4.

Drive Assembly Removal and Installation

To install the drive assembly onto the motor 
assembly:

1.  Be  sure  all  electrical  breakers  and  switches  are 

turned off before installing the drive.

2.  Be sure that the gasket between the drive and motor 

is in place. It is critical in keeping moisture out of the 

drive and motor. Replace the gasket if damaged. Do 

not reassemble with a damaged or missing gasket.

3.  Verify that the three (3) orange motor post caps are 

in position before placing the drive on the motor 
assembly. 

4.  Align the drive assembly with the motor adapter and 

seat the drive on the motor assembly.

5.  Secure and tighten the drive assembly with the three 

Phillips head screws.

Before installing this product, read and follow all 
warning notices and instructions on pages ii - iii.

FIRE and BURN HAZARD - The pump motor 
may run at a high temperatures. To reduce the 

risk of fire, do not allow leaves, debris, or foreign matter to collect 
around the pump motor. To avoid burns when handling the motor, shut 
off the motor and allow it to cool for 20 minutes before servicing. The 
pump provides an automatic internal cutoff switch to protect the motor 
from heat damage during operation.

Drive Assembly and Removal

Phillips Head 

Screws

Phillips Head 

Screw

Do not remove 
these screws

Adapter 

Connector

 Gasket

 Orange Motor 

Post Caps 

(QTY. 3)

Alerts and Warnings

The IntelliFloXF

® 

Variable Speed Pump displays all 

alarms and warnings on the control panel display. When 
an alarm or warning condition exists, the corresponding 

light will be lit on the display. 

All control panel buttons are disabled until the alarm or 
warning is acknowledged with the Enter button.  Press 
the  Reset  button  to  clear  the  alarm  once  the  fault 

condition has been resolved. 

Note:

 

The pump will not start if the impeller is rotating. 

Power Out Failure 

The incoming supply voltage is less than 170 VAC.  

The drive faults to protect itself from over current. The 
drive contains capacitors that keep it powered up long 
enough to save the current run parameters. If power 

is restored during this process, approximately 20 sec

-

onds, the drive will not restart until completed.

Priming Error

If the pump is not defined as primed within the “Max 
Priming  Time”  it  will  stop  and  generate  a    “Priming 
Alarm” for 10 minutes, then attempt to prime again. The 
“Max Priming Time” is set by the user on the priming 
menu  as  discussed  on  page  14.  If  the  pump  cannot 

prime within five attempts it will generate a permanent 
alarm that must be manually reset.

Overheat Alert

If the drive temperature gets above 54.4° C (130° F) 

the pump will slowly reduce speed until the over 
temperature condition clears.

Anti-Freezing

When active, the motor will run at the preset RPM until 

the drive temperature increases above the minimum. 

The pump’s internal antifreeze protection is disabled 
when  connected  to  an  automation  system.  Freeze 
protection is provided by selecting YES at the ON WITH 
FREEZE  portion  of  the  circuit  function  menu  in  the 

IntelliTouch

®

 Control System. To re-enable the internal 

antifreeze protection, the power to the drive must be 

cycled off then back on. 

Important: See explanation 

of Anti-Freeze mode on page 16.
Over Current

Indicated that the drive is overloaded or the motor has 

an electrical problem. The drive will restart 20 seconds 

after the over current condition clears.

Over Voltage

Indicates excessive supply voltage or an external 
water source is causing the pump and motor to rotate 
thereby generating an excessive voltage on the drives 

internal DC buss. The drive will restart 20 seconds 

after the over voltage condition clears.

Содержание IntelliFloXF

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP...

Страница 2: ...peed Pump Operating Modes Control Panel Language Operator Control Panel Menu Guide Pump Settings Pump Address Set Time AM PM or 24 Hour Clock Set Temperature Unit Screen Contrast Level Set Min Max Spe...

Страница 3: ...NUAL BEFORE USING THIS PUMP THESE WARNINGSAND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROMALLSUCTION OUTLETS THE USE OF UNAPPROVED C...

Страница 4: ...f suction can pose a risk if a person comes within the close proximity of the suction openings A person can be seriously injured by this high level of vacuum or may become trapped and drown It is abso...

Страница 5: ...ll the retainer ring with the tab features pointing away from the nut Union Adapter Installation Installing the locking union onto the pump 1 Glue the PVC union adapter fitting to the PVC pipe The ada...

Страница 6: ...ump prime faster and last longer Fittings and Valves 1 Do not install 90 elbows directly into pump inlet 2 Flooded suction systems should have gate valves installed on suction and discharge pipes for...

Страница 7: ...ntlyconnectedtoeither a circuit breaker 2 pole timer or 2 pole relay If AC power is supplied by a GFCI circuit breaker use a dedicated circuit breaker that has no other electrical loads 10 IMPORTANT W...

Страница 8: ...or after servicing DO NOT run the pump dry If the pump is run dry the mechanical seal will be damaged and the pump will start leaking If this occurs the damaged seal must be replaced ALWAYS maintain...

Страница 9: ...ls and LEDs on Key Pad Quick Clean Pump ramps up to higher RPM for vacuuming cleaning adding chemicals and after a storm for extra skimmer power LED light is on when active Time Out Pump is not runnin...

Страница 10: ...Speeds 1 4 can be programmed in all three modes Speeds 5 8 can only be programmed in Schedule mode since there are no buttons on the control panel for Speeds 5 8 The default setting for Speeds 5 8 is...

Страница 11: ...ion 1 min to 10 hrs Default 3 hours 1 min to 30 min Default 11 minutes Disabled Enabled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Sta...

Страница 12: ...ess 4 To change the pump address press Select 5 Press Up or Down arrows to change the address number from 1 16 6 Press Enter to save To cancel any changes press Escape to exit without saving 7 Press E...

Страница 13: ...on of four 4 digits Password protection can always be turned off by pressing Start Stop Password protection cannot be turned back on with Start Stop while running in manual mode Pressing Start Stop wh...

Страница 14: ...is means the IntelliFloXF Variable Speed Pump will go into Password Protection mode 10 minutes after the last control panel key is pressed 8 Press Select to change time setting from 1 minute to 6 hour...

Страница 15: ...o display Time 8 Press Select and use arrow keys to adjust time 9 Press Enter to save the new time setting 10 Press Escape to exit Manual Assigns a speed to one of the four Speed buttons on the contro...

Страница 16: ...displayed Note The pump will not run the scheduled speeds until the Start Stop button is pressed LED on to place the pump in Schedule mode Note When two speeds are scheduled during the same run time...

Страница 17: ...will be lit and ready to turn on at the next scheduled run time To access the Time Out menu 1 Check that the green power LED is on 2 Press Menu 3 Use Up or Down arrows to scroll to Features then pres...

Страница 18: ...er and restart the pump Default 20 seconds Priming delay can be set from 1 second to 10 minutes If the pump does not have enough water after the automatic priming mode the pump will ramp to the Maximu...

Страница 19: ...ck to page 14 for instructions on accessing the priming menu and features 1 Disable priming on automation control system 2 Disconnect the RS 485 communication cable To disable priming with an automati...

Страница 20: ...4 The factory default for Anti Freeze is Enabled To disable Anti Freeze press Select to highlight Enabled 5 Press the Up arrow Disabled is displayed 6 Press Enter to save To Set Anti Freeze Speed and...

Страница 21: ...r 15 100 VDC 1 mA 1 Input 50 60 Hz 5 6 Program 2 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 7 8 Program 3 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 9 10 Program 4 15 240 VAC or 15 100 VDC 1 m...

Страница 22: ...o the COM port screw terminals 2 and 3 Be sure to match the color coding of the wires YELLOW to YELLOW and GREEN to GREEN The Red wire is not connected Secure the wires with the screws IntelliTouch CO...

Страница 23: ...oltage raceway to the motherboard Connecting the Pump to a SunTouch Control System 4 Strip back the cable conductors 6 mm 1 4 Insert the wires into the screw terminals provided Secure the wires with t...

Страница 24: ...hout water in the strainer pot Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water Opening the pump may cause serious personal injury I...

Страница 25: ...s ventilation Protect against dirt 1 Protect from any foreign matter 2 Do not store or spill chemicals on or near the motor 3 Avoid sweeping or stirring up dust near the motor while it is operating 4...

Страница 26: ...ith water 11 Reinstall the pump lid and locking ring see Cleaning the Pump Strainer Basket on page 20 12 Prime the system See page 4 for priming instructions Drive Assembly Removal and Installation To...

Страница 27: ...rm or warning is acknowledged with the Enter button Press the Reset button to clear the alarm once the fault condition has been resolved Note The pump will not start if the impeller is rotating Power...

Страница 28: ...ti spin bolt and o ring 3 Remove clean and reinstall impeller 4 Reinstall anti spin bolt and o ring Reinstall diffuser and o ring Reinstall motor and seal plate into volute Reinstall clamp band around...

Страница 29: ...is open Motor runs too hot Turn power to motor off Check for proper voltage Check for proper impeller or impeller rubbing Mechanical Troubles and Noise The pump motor is running but with loud noise F...

Страница 30: ...Washer U43 12SS 17 Flat Washer 072184 18 Diffuser O Ring 350336 REPLACEMENT PARTS Item No Description IntelliFloXF IntelliProXF 19 Diffuser Screw 353323 20 Diffuser 400010 21 Impeller Reverse Screw 3...

Страница 31: ...mic Head in Ft of H2O Speed 1 750 rpm Speed 2 1560 rpm Speed 3 2350 rpm Speed 4 3110 rpm Max Speed 3450 rpm Pump Dimensions ANCHOR BOLT MOUNTING LOCATIONS 298 mm 11 7 in 232 mm 9 125 in 166 mm 6 5 in...

Страница 32: ...abled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Start Time Set Stop Time Disabled Default Disabled Default Enabled 1 100 Default 1 1...

Страница 33: ...NOTES...

Страница 34: ...NOTES...

Страница 35: ...NOTES...

Страница 36: ...nless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentai...

Отзывы: