Limited Warranty on Hypro/SHURflo Agricultural Pumps & Accessories

Hypro/SHURflo  (hereafter,  “Hypro”)  agricultural  products  are  warranted  to  be  free  of  defects  in  material  and  workmanship  under

 

normal use for the time periods listed below, with proof of purchase.

 

 

- Accessories: ninety (90) days of use.

This limited warranty will not apply to products that were improperly installed, misapplied, damaged, altered, or incompatible with 

fluids or components not manufactured by Hypro. All warranty considerations are governed by Hypro’s written return policy. 

Hypro’s obligation under this limited warranty policy is limited to the repair or replacement of the product. All returns will be tested 

per Hypro’s factory criteria. Products found not defective (under the terms of this limited warranty) are subject to charges paid by the return

-

ee for the testing and packaging of “tested good” non-warranty returns. 

No credit or labor allowances will be given for products returned as defective. Warranty replacement will be shipped on a freight allowed 

basis. Hypro reserves the right to choose the method of transportation. 

This limited warranty is in lieu of all other warranties, expressed or implied, and no other person is authorized to give any other 

warranty or assume obligation or liability on Hypro’s behalf. Hypro shall not be liable for any labor, damage or other expense, nor  

shall Hypro be liable for any indirect, incidental or consequential damages of any kind incurred by the reason of the use or sale of 

any defective product. This limited warranty covers agricultural products distributed within the United States of America. Other world market 

areas should consult with the actual distributor for any deviation from this document.

Return Procedures

All products must be flushed of any chemical (ref. OSHA section 1910.1200 (d) (e) (f) (g) (h)) and hazardous chemicals must be labeled/

tagged before being shipped* to Hypro for service or warranty consideration. Hypro reserves the right to request a Material Safety Data 

Sheet from the returnee for any pump/product it deems necessary. Hypro reserves the right to “disposition as scrap” products returned 

which contain unknown fluids. Hypro reserves the right to charge the returnee for any and all costs incurred for chemical testing, and proper 

disposal of components containing unknown fluids. Hypro requests this in order to protect the environment and personnel from the hazards 

of handling unknown fluids.

Be prepared to give Hypro full details of the problem, including the model number, date of purchase, and from whom you purchased your 

product. Hypro may request additional information, and may require a sketch to illustrate the problem. 

Contact Hypro Service Department at 800-468-3428 to receive a Return Merchandise Authorization number (RMA#). 

Returns are to be shipped with the RMA number clearly marked on the outside of the package. Hypro shall not be liable for freight damage 

incurred during shipping. Please package all returns carefully. All products returned for warranty work should be sent 

shipping  charges   

prepaid

 to:

 

HYPRO / PENTAIR

 

Attention: Service Department

 

375 Fifth Avenue NW

 

New Brighton, MN  55112

For technical or application assistance, call the 

Hypro Technical/Application number: 800-445-8360

, or send an email to: 

technical@

hypropumps.com

. To obtain service or warranty assistance, call the 

Hypro Service and Warranty number

800-468-3428

;    or send a 

fax to the 

Hypro Service and Warranty FAX

651-766-6618

.

*Carriers, including U.S.P.S., airlines, UPS, ground freight, etc., require specific identification of any hazardous material being shipped. Failure to do so may 

result in a substantial fine and/or prison term. Check with your shipping company for specific instructions.

375 Fifth Avenue NW 

 New Brighton, MN 55112

Phone: (651) 766-6300 

 800-424-9776 

 Fax: 800-323-6496

www.hypropumps.com

Hypro (08/14) 

Printed in USA 

Visit www.hypropumps.com/register today to register 

your product and stay up-to-date on new products and 

promotional offers.

The following information is required:     

 

Model # _______________  Serial # _______________

- 12 -

Содержание Hypro 3377 Series

Страница 1: ...hypropumps com Hypro Series 3377 Form L 1566 Rev A Original Instruction Manual KEEP FOR FUTURE REFERENCE 3377 1670 3377 1671 3377 1170 3377 1171 Framed Unframed Closed System Cleanload Pentair 375 5th...

Страница 2: ...5 Lifting Transport and Intermediate Storage 5 Assembly and Installation 5 Assembly 5 Installation 5 Control Systems 6 Commissioning Start Up Operation Shutdown 7 Information 7 Start Up Operation Shu...

Страница 3: ...of this product of procedures that may be dangerous to the user or result in damage to the product ATTENTION Attention is used to notify of installation operation or maintenance information that is i...

Страница 4: ...33 L min Operating Temperature 34 115 F 1 46 C Weight 90 lbs 40 8 Kg 3377 1170 3377 1171 Input Pressure PSI Eduction Rate gal sec Flow Rate gal min 20 0 57 27 06 40 0 86 38 09 60 0 85 44 58 80 1 21 50...

Страница 5: ...sult the manufacturer s documentation for the equipment on which you are mounting the Cleanload to identify suitable plumbing connections and mounting locations Securely mount the Cleanload in a place...

Страница 6: ...All pump systems with electric or hydraulic power sources are required to have a control system which meets all local and national standards For more detail on a typical system installation see preced...

Страница 7: ...r being drawn into the line and not backing up inside the enclosure If water backs up in enclosure when the pump is on ensure the tank valve red handle is open to allow flow from the enclosure If the...

Страница 8: ...witching chemicals or if the system is going to be inactive for an extended period of time Ensure that the components of the Cleanload are free of any chemical buildup or residue both inside and out F...

Страница 9: ...pper outlet with the hopper valve open observe the liquid jet should be centered and straight If it is off center or if it is dispersed flush the system with clean water and remove the fittings from b...

Страница 10: ...Valve 23 1 PV1 2F 3607S Nozzle 24 1 3430 0861 Kit Cleanload CS Hose B 1 5 4 12 9 3 6 10 7 8 2 11 22 13 14 18 17 16 15 14 20 21 19 23 24 3377 1670 3377 1671 3377 1170 3377 1170 Replacement Parts The fo...

Страница 11: ...Notes 11...

Страница 12: ...deration Hypro reserves the right to request a Material Safety Data Sheet from the returnee for any pump product it deems necessary Hypro reserves the right to disposition as scrap products returned w...

Отзывы: