Installation

Instructions

After taking the above 

precautions, lower the 12V 

 

battery into the enclosure with the 

terminals facing the front of the 

Unit where the indicator lights 

and battery cables are located. 

At this time check the polarity of 

your marine battery. Facing the 

front of the Unit, the left battery 

terminal should be positive and 

the right, negative. If this is not 

the case do not continue until the 

proper battery can be obtained. 

(Do not try to correct this problem 

in any other way than by using the 

proper battery.)

Functions and Lights:

1.  With the pump plugged into the power cord receptacle, the power 

cord plugged into a building receptacle:

   

A.   Power loss (inverter on) light  

OFF

   

B.   Battery charging light  

ON

   

C.   Fully charged light 

ON

2.  With the pump plugged into the power cord receptacle, the power 

cord plugged into a building receptacle, battery installed and  

connected, RECEPTACLE POWER ON:

   

A.  Power loss (inverter on) light  

OFF

   

B.  Battery charging light 

ON

   

C.  Fully charged light  

OFF

   

D.  (If fully charged, light) 

(ON)

3.  With the pump plugged into the power cord receptacle, the power 

cord plugged into a building receptacle, battery installed and 

connected, RECEPTACLE POWER OFF:

   

A.  Power loss (inverter on) light  

ON

   

B.  Battery charging light 

OFF

   

C.  Fully charged light  

OFF

   

D.  (If fully charged, light) 

(ON)

4.  AFTER EACH 5 MINUTES OF OPERATION, the Unit halts 

inverter operation for 5 seconds to test for receptacle power, pump 

stops: 

   

A.  Power loss (inverter on) light  

OFF

   

 

(may slowly dim)

   

B.  Battery charging light 

OFF

   

C.  Fully charged light 

OFF

   

D.   If receptacle power is found to be present, 

   

 

see # 2 above.

   

E.  If receptacle power is found to be off, 

   

 

see # 3 above.

5.  If battery voltage falls below a usable charge, PUMP WILL STOP:

     

A. 

Power loss (inverter on) light OFF

     

B. 

Battery charging light  

FLASH

     

C. 

Fully charged light    

OFF

6.  Battery voltage may recover and allow brief periods of operation.

Now that the battery has been 

installed with the terminals 

nearest to the red and black wires, 

PLUG THE UNIT INTO A 120V 

OUTLET BEFORE CONNECTING 

THE BATTERY LEADS. With 

the Unit plugged into the 120V 

outlet connect the battery leads 

to the marine battery making 

sure the red wire is connected to 

the positive terminal and black  

wire is connected to the negative 

terminal. Make sure all battery 

connections are properly tightened 

to 75 inch pounds. Then place 

the battery box cover back on 

the Unit and strap it down so that 

children cannot tamper with the 

Unit. At this time you may plug 

the high efficiency pump supplied 

with the System into the back of 

the piggyback plug on the Unit.  

DO NOT PLUG ANY OTHER PUMP THAN THE PUMP 

SUPPLIED WITH THE UNIT INTO THE UNIT.  DOING SO 

WILL VOID THE WARRANTY!

Содержание HYDROMATIC A+

Страница 1: ... 957 8677 Unit Installation and Service Manual A Battery Backup Power Supply For use with Hydromatic model B A1 BV A1 2013 Pentair Ltd All Rights Reserved W 03 422 Rev 03 04 13 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system ...

Страница 2: ...attery Backup System is to be used only with the Hydromatic pump supplied with the Unit Using anything other than the pump supplied with the system will cause damage to the Unit and void the warranty Tools Needed A pipe wrench pliers adjustable wrench and screwdriver will be needed Battery Requirements Your Unit operates on 12V DC battery power when in the power fail mode a UL recognized deep cycl...

Страница 3: ...rging light OFF C Fully charged light OFF D If fully charged light ON 4 AFTER EACH 5 MINUTES OF OPERATION the Unit halts inverter operation for 5 seconds to test for receptacle power pump stops A Power loss inverter on light OFF may slowly dim B Battery charging light OFF C Fully charged light OFF D If receptacle power is found to be present see 2 above E If receptacle power is found to be off see...

Страница 4: ...dried e CAUTION Lead acid batteries can present a risk of fire because they generate hydrogen gas The following procedures should be followed f DO NOT SMOKE when near batteries g DO NOT cause flame or spark in battery area h Discharge static electricity from body before touching batteries by first touching a grounded metal surface 11 See battery manufacturer s installation manual for additional ba...

Страница 5: ... by customer 100 10 20 30 40 50 60 70 80 90 1 2 3 4 5 6 7 8 9 10 11 A Battery Backup performance with a Hydromatic B A1 Pump Run Time hours Duty Cycle percent Test results are based on the following criteria Pump Current Draw 5 8 Amps Specific gravity of battery fluid at the start of each test 1300 Start 13 45 Volts Finish 10 2 Volts 7 Unit has been applied to products exceeding the maximum capaci...

Страница 6: ...6 This page intentionally left blank ...

Страница 7: ...7 This page intentionally left blank ...

Страница 8: ... be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQ...

Отзывы: