Note

  Charging the battery in this 

Unit should not take longer 

than 36 hours.

Testing

:

 

  To test the Unit simply unplug 

it from the receptacle and add 

water to sump until pump 

pumps sump down. Run the 

pump supplied with the Battery 

Backup System for only a 

few cycles. You can repeat 

this if you wish, but it is not 

necessary. If the Unit works 

the first time it is sure to work 

time and time again. Be sure 

that you remember to plug the 

Unit back into the receptacle 

after you have completed the 

test. NOTE: If while testing 

the Unit the pump does not 

turn on, the following steps 

should be taken: 

1.  Check the charger and inverter 

lights to see if they are on. 

2.  Check the circuit breaker. 

3. Plug the pump you have 

plugged into the Unit directly 

into a live building receptacle. 

If the pump runs, recheck all 

the battery connections and 

battery voltage.

4.  Check sump water level to see 

that pump is being required  

to run.

5.  If the above items have been 

thoroughly checked and 

your pump will still not run 

when plugged into the Unit, 

remove the battery from the 

battery box as described in the 

assembly instructions and 

return the Unit to the place 

of purchase for repair or 

replacement.

  d. Spilled electrolyte should be 

washed down with a suitable 

acid neutralizing agent. A 

common practice is to use a 

solution of approximately one 

pound (500 grams) bicarbonate 

of soda to approximately one 

gallon (4 liters) of water. The 

bicarbonate of soda solution 

should be added until the 

 

evidence of reaction (foaming) 

has ceased. The resulting 

 

liquid should be flushed with 

water and the area dried.

 e. CAUTION: Lead acid 

batteries can present a risk 

of fire because they generate 

hydrogen gas. The following 

procedures should be 

 

followed:

 f. 

DO NOT SMOKE when 

near batteries.

 g. 

DO NOT cause flame or 

spark in battery area.

  h. Discharge static electricity 

from body before touching 

batteries by first touching a 

grounded metal surface.

11. 

See battery manufacturer’s 

installation manual for 

additional battery installation 

and maintenance instructions.

  Your Unit has been designed 

to be virtually maintenance 

free. Just make sure it is kept 

clean and dry and that the Unit 

is periodically tested.

Battery

Maintenance

1. Servicing of batteries should 

be performed or supervised 

by personnel knowledgeable 

of batteries and the required 

precautions. 

  Keep unauthorized personnel 

away from batteries.

2. When replacing the battery, 

use the same type of battery 

(see battery requirements for 

ordering information).

3.  CAUTION: Do not dispose of 

battery in a fire. The battery 

may explode.

4.  CAUTION: Do not open or 

mutilate the battery. Released 

electrolyte is harmful to the 

skin and eyes. It may be toxic.

5.  CAUTION: A battery can 

present a risk of severe burn 

and injury from high short 

circuit current. The following 

precautions should be observed 

when working on batteries. 

6. Remove watches, rings, or 

other metal objects. 

7. Use tools with insulated 

handles.

8. Do not lay tools or metal 

objects on top of batteries.

9.  CAUTION: The electrolyte 

is a dilute sulfuric acid that is 

harmful to the skin and eyes.  

It is electrically conductive 

and corrosive. The following 

procedures should be observed:

  a. Wear full eye protection and 

clothing.

  b. If electrolyte contacts the 

skin, wash it off immediately.

  c. If electrolyte contacts the 

eyes, flush thoroughly and 

immediately with water. Seek 

medical attention.

Содержание HYDROMATIC A+

Страница 1: ... 957 8677 Unit Installation and Service Manual A Battery Backup Power Supply For use with Hydromatic model B A1 BV A1 2013 Pentair Ltd All Rights Reserved W 03 422 Rev 03 04 13 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system ...

Страница 2: ...attery Backup System is to be used only with the Hydromatic pump supplied with the Unit Using anything other than the pump supplied with the system will cause damage to the Unit and void the warranty Tools Needed A pipe wrench pliers adjustable wrench and screwdriver will be needed Battery Requirements Your Unit operates on 12V DC battery power when in the power fail mode a UL recognized deep cycl...

Страница 3: ...rging light OFF C Fully charged light OFF D If fully charged light ON 4 AFTER EACH 5 MINUTES OF OPERATION the Unit halts inverter operation for 5 seconds to test for receptacle power pump stops A Power loss inverter on light OFF may slowly dim B Battery charging light OFF C Fully charged light OFF D If receptacle power is found to be present see 2 above E If receptacle power is found to be off see...

Страница 4: ...dried e CAUTION Lead acid batteries can present a risk of fire because they generate hydrogen gas The following procedures should be followed f DO NOT SMOKE when near batteries g DO NOT cause flame or spark in battery area h Discharge static electricity from body before touching batteries by first touching a grounded metal surface 11 See battery manufacturer s installation manual for additional ba...

Страница 5: ... by customer 100 10 20 30 40 50 60 70 80 90 1 2 3 4 5 6 7 8 9 10 11 A Battery Backup performance with a Hydromatic B A1 Pump Run Time hours Duty Cycle percent Test results are based on the following criteria Pump Current Draw 5 8 Amps Specific gravity of battery fluid at the start of each test 1300 Start 13 45 Volts Finish 10 2 Volts 7 Unit has been applied to products exceeding the maximum capaci...

Страница 6: ...6 This page intentionally left blank ...

Страница 7: ...7 This page intentionally left blank ...

Страница 8: ... be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQ...

Отзывы: