![Pentair FLECKXT Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/pentair/fleckxt/fleckxt_service-manual_1524522009.webp)
FLECK
XT Service Manual
•
9
MASTER PROGRAMMING MODE
CONTINUED
8. Volume Override
This program step is used to set the volume override of the unit.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
9. Regeneration Day Override
This program step sets the maximum amount of time (in days)
the unit can be in service without a regeneration.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
10. Regeneration Time
This program step sets the time of day for the regeneration to
occur in delayed systems.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
11. Regeneration Cycle Step Programming
This program step programs the Regeneration Cycle step
times 1 through 5. Please refer to the chart below for
regenerant flow default cycle steps and times.
Regenerant
Flow
Cycle 1
Time
Cycle 2
Time
Down Flow
Back Wash 10 Minutes
Brine &
Slow Rinse
1 Hour
Back Wash
Filter
Back Wash 15 Minutes
Draw
0
UF Variable
Fill
Brine &
Slow Rinse
10 Minutes
Pause &
Delay
1 Hour
Upflow
Brine &
Slow Rinse
1 Hour
Back Wash 10 Minutes
Regenerant
Flow
Cycle 3
Time
Cycle 4
Time
Down Flow
Rapid
Rinse
10 Minutes
Brine Tank
Fill
12 Minutes
Back Wash
Filter
Settling
Rinse
10 Minutes
Refill
0
UF Variable
Fill
Variable
Rapid
Rinse
N/A
Brine Tank
Fill
12 Minutes
Upflow
Rapid
Rinse
10 Minutes
Brine Tank
Fill
12 Minutes
Regenerant
Flow
Cycle 5
Time
Down Flow
N/A
N/A
Back Wash
Filter
N/A
N/A
UF Variable
Fill
Rapid
Rinse
10 Minutes
Upflow
N/A
N/A
12. Media Volume
This program step sets the volume of the media in the resin tank.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
13. Salt Dosage
This program step sets the salt dosage in the unit.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
Содержание FLECKXT
Страница 1: ...www pentairaqua com FLECK XT SERVICE MANUAL...
Страница 7: ...FLECK XT Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...
Страница 13: ...FLECK XT Service Manual 13 2510 2750 2850 2850S POWER HEAD ASSY 61501 3200XT 2_2750XT_2850XT_REVA 32 33 34...
Страница 17: ...FLECK XT Service Manual 17 61501 3200XT_3150XT_REVA 3150 POWER HEAD ASSY...
Страница 19: ...FLECK XT Service Manual 19 61501 3200XT_3900XT_REVA 3900 POWER HEAD ASSY...
Страница 21: ...FLECK XT Service Manual 21 9000 9100 9500 POWER HEAD ASSY 61501 3200XT 9_REVA...
Страница 23: ...FLECK XT Service Manual 23 WIRING DIAGRAMS Single Piston...
Страница 24: ...24 FLECK XT Service Manual WIRING DIAGRAMS CONTINUED Dual Piston...
Страница 26: ...26 FLECK XT Service Manual...
Страница 27: ...FLECK XT Service Manual 27...