DIAGNOSTIC PROGRAMMING MODE
NOTE:
Depending on current option settings, some displays
cannot be viewed.
Overview Diagnostic Mode
The current Diagnostic Programming Mode screen will display
until either the Extra Cycle button is pressed through for each
screen, or the Diagnostic button is pressed. In the event of
regeneration occurring while in the Diagnostic Programming
Mode, the regeneration step and time remaining will be
displayed. When regeneration completes, the display will
return to the normal time of day display screen.
Entering and Exiting Diagnostic Mode
Press and release the “D” button to enter the Diagnostic
Programming Mode. Pressing the Extra Cycle button will move to
the next diagnostic screen. Press the Extra Cycle button once per
display until all are viewed. Pressing the Diagnostic button while
in Diagnostic Mode will cause the unit to leave the Diagnostic
Mode and return to the normal time of day display screen.
1. Current Flow Rate
This program step displays the calculated flow rate for the
timer. The below flow rates are the maximum flow rate the
timer will read for each meter.
.75 Inch Paddle:
15 gpm (0.06 m
3
/m)
.75 Inch Turbine: 15 gpm (0.06 m
3
/m)
1 Inch Paddle:
40 gpm (0.15 m
3
/m)
1 Inch Turbine:
90 gpm (0.34 m
3
/m)
1.5 Inch Paddle:
180 gpm (0.68 m
3
/m)
1.5 Inch Turbine: 90 gpm (0.34 m
3
/m)
2 Inch Paddle:
350 gpm (1.32 m
3
/m)
3 Inch Paddle:
500 gpm (1.89 m
3
/m)
• Press the Extra Cycle button.
2. Peak Flow Rate
This program step displays the peak flow rate (1 minute
average) since the last regeneration.
• Press the Extra Cycle button.
3. Totalizer
This program step displays the total volume of treated water
that passes through the meter.
• Reset to zero by holding the Up and Down buttons for five
seconds while in the totalizer screen.
• Press the Extra Cycle button.
4. Hours Between Last Two Regenerations
This program step displays the time between the last two
regenerations saved.
• Press the Extra Cycle button.
5. Hours Since Last Regeneration
This program step displays the hours since the last regeneration.
• Press the Extra Cycle button.
6. Volume Remaining
This program step displays the volume remaining. The timer
will regenerate if the volume remaining is set to zero. The
maximum ranges are the same as the maximum volume
calculated on the main screen.
• Press the Extra Cycle button.
7. Previous Day’s Water Usage
This program step displays the previous day’s water usage.
• Press the Extra Cycle button.
8. Reserve Volume
This program step displays the reserve capacity, ensuring soft
water is available at all times.
• Press the Extra Cycle button.
9. Software Version
This program step displays the timer’s software program
version number.
• Press the Extra Cycle button to exit.
NOTE:
Diagnostic Programming Mode will stop if the system
goes into a regeneration.
Содержание FLECKXT
Страница 1: ...www pentairaqua com FLECK XT SERVICE MANUAL...
Страница 7: ...FLECK XT Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...
Страница 13: ...FLECK XT Service Manual 13 2510 2750 2850 2850S POWER HEAD ASSY 61501 3200XT 2_2750XT_2850XT_REVA 32 33 34...
Страница 17: ...FLECK XT Service Manual 17 61501 3200XT_3150XT_REVA 3150 POWER HEAD ASSY...
Страница 19: ...FLECK XT Service Manual 19 61501 3200XT_3900XT_REVA 3900 POWER HEAD ASSY...
Страница 21: ...FLECK XT Service Manual 21 9000 9100 9500 POWER HEAD ASSY 61501 3200XT 9_REVA...
Страница 23: ...FLECK XT Service Manual 23 WIRING DIAGRAMS Single Piston...
Страница 24: ...24 FLECK XT Service Manual WIRING DIAGRAMS CONTINUED Dual Piston...
Страница 26: ...26 FLECK XT Service Manual...
Страница 27: ...FLECK XT Service Manual 27...