JOB SPECIFICATION SHEET
NOTE:
Some options may not be available depending on
valve model or other options chosen.
Circle and/or Fill in the Appropriate Data for Future Reference:
1. System Type:
A. Meter Immediate
B. Time Clock Delayed
C. Twin Tank
D. Volume Override Delay
E. Volume Override Immediate
F. Remote Signal Start Delayed
G. Remote Signal Start Immediate
H. Meter Delayed Week Reserve
I. Meter Delayed Variable Reserve
J. Meter Delay Fixed Reserve
2. Valve Type:
A. 2510/2850
B. 2750
C. 2900
D. 3150
E. 3900
F. 9000/9100/9500
G. Proprietary A B E
3. Regenerant Flow:
A. Down Flow
B. UF Variable Fill
C. UF Brine First
D. Downflow DB BW
E. UF Backwash / Back Wash Filter
4. Initial Tank:
A. Tank 1
B. Tank 2
5. Remote Signal Start:
A. On
B. Off
6. Display Format:
A. U.S.
B. Metric (French Degrees, German Degrees, or PPM)
7. Unit Capacity:
__________Grains/French Degrees/German Degrees/PPM
8. Water Hardness:
__________Grains/French Degrees/German Degrees/PPM
9. Capacity Safety Factor:
A. Zero
B. __________%
10. Volume Override: __________(Gallons or M
3
)
11. Regeneration Day Override:
A. Off
B. Every __________Days
12. Regeneration Time:
Regeneration Cycle Step #1: _ _ : _ _ : _ _
Regeneration Cycle Step #2: _ _ : _ _ : _ _
Regeneration Cycle Step #3: _ _ : _ _ : _ _
Regeneration Cycle Step #4: _ _ : _ _ : _ _
Regeneration Cycle Step #5: _ _ : _ _ : _ _
A. Delayed __________AM/PM
B. __________Immediate
13. Media Volume: __________(CuFt or Liter)
14. Salt Dosage: __________(lbs/CuFt or grams/Liter)
15. BLFC Size: __________gpm
16. Auxiliary Relay:
A. Enabled
Auxiliary Relay Start 1:_ : _ _ : _ _
Auxiliary Relay End 1:_ : _ _ : _ _
Auxiliary Relay Start 2:_ : _ _ : _ _
Auxiliary Relay End 2:_ : _ _ : _ _
B. Disabled
17. Chemical Pump:
A. Enabled
B. Disabled
18. CPO Aux Relay Volume: __________(Gallons or M
3
)
19. CPO Aux Relay:_ _ : _ _ : _ _
20. Flow Meter Size:
A. Paddle:
.75 Inch
1.0 Inch
1.5 Inch
2.0 Inch
3.0 Inch
B. Turbine:
.75 Inch
1.0 Inch
1.5 Inch
21. Generic Flow Meter:
Maximum Flow Rate: Add _ _ Gallons every _ _Pulses
Содержание FLECKXT
Страница 1: ...www pentairaqua com FLECK XT SERVICE MANUAL...
Страница 7: ...FLECK XT Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...
Страница 13: ...FLECK XT Service Manual 13 2510 2750 2850 2850S POWER HEAD ASSY 61501 3200XT 2_2750XT_2850XT_REVA 32 33 34...
Страница 17: ...FLECK XT Service Manual 17 61501 3200XT_3150XT_REVA 3150 POWER HEAD ASSY...
Страница 19: ...FLECK XT Service Manual 19 61501 3200XT_3900XT_REVA 3900 POWER HEAD ASSY...
Страница 21: ...FLECK XT Service Manual 21 9000 9100 9500 POWER HEAD ASSY 61501 3200XT 9_REVA...
Страница 23: ...FLECK XT Service Manual 23 WIRING DIAGRAMS Single Piston...
Страница 24: ...24 FLECK XT Service Manual WIRING DIAGRAMS CONTINUED Dual Piston...
Страница 26: ...26 FLECK XT Service Manual...
Страница 27: ...FLECK XT Service Manual 27...