TIMER OPERATION

Setting the Time of Day

NOTE: Set Time of Day on the Lead Unit (#1) and the rest of 

the units in the system will update the Time of Day 

within 10 seconds.

1.  Press and hold the Up or Down button for 2 seconds.
2.  Press the Shift button to select the digit you want to modify.
3.  Press the Up or Down buttons to adjust the valve.
4.  Press the Extra Cycle button to return to the normal display 

screen, or wait for a 5 second timeout.

NOTE: The "D" button (Diagnostic) can be pressed to exit 

without saving.

Manually Initiating a Regeneration

1.  When timer is In Service or Stand By, press the Extra Cycle 

button for 5 seconds on the main screen.

2.  The timer advances to Regeneration Cycle Step #1, and 

begins programmed time count down.

3.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #2 (if active).

4.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #3 (if active).

5.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #4 (if active).

6.  Press the Extra Cycle button once to advance valve to 

Regeneration Cycle Step #5 (if active).

7.  Press the Extra Cycle button once more to advance the 

valve back to In Service.

NOTE: A manually initiated or queued regeneration can 

be cleared by pressing the Extra Cycle button for 

less than 5 seconds. A system queued regeneration 

can only be cleared by stepping through a manual 

regeneration. If regeneration occurs for any reason 

prior to the delayed regeneration time, the manual 

regeneration request shall be cleared. Pressing 

the Extra Cycle button while in regeneration will 

cause the upper drive to advance to the next step 

immediately.

Timer Operation During Regeneration

In the Regeneration Cycle step display, the timer shows 

the current regeneration cycle number the valve is in, or 

has reached, and the time remaining in that step. Once all 

regeneration steps are complete the timer returns to In Service 

and resumes normal operation. 

CYCLE 1 00:00:00
       BACK WASH

Example:

 12 minutes remaining in Cycle 1 (Backwash)

Press the Extra Cycle button during a system 

queued Regeneration Cycle to immediately 

advance the valve to the next cycle step position 

and resume normal step timing.

Flow Meter Equipped Timer

As treated water is used, the Volume Remaining display counts 

down from the calculated system capacity to zero. When zero 

is reached a Regeneration Cycle begins if no other units are in 

regeneration.

Timer Operation During Programming

The timer enters the Program Mode in Standby or Service 

Mode as long as it is not in regeneration. While in the Program 

Mode the timer continues to operate normally monitoring 

water usage. Timer programming is stored in memory 

permanently.

Timer Operation During A Power Failure

All program settings are stored in permanent memory. Current 

valve position, cycle step time elapsed, and time of day are all 

stored during a power failure, and will be restored when power 

is re-applied. Time is kept during a power failure, and time of 

day is adjusted upon power up (as long as power is restored 

within 12 hours).

NOTE: The time of day on the main display screen will flash 

for 5 minutes when there has been a power outage. 

The flashing of the time of day can be stopped by 

pressing any button on the display.

Remote Lockout 

The timer does not allow the unit/system to go into 

Regeneration until the Regeneration Lockout Input signal to 

the unit is cleared. This requires a contact closure to activate 

the unit. The recommended gauge wire is 20 with a maximum 

length of 500 feet. See P4 remote inputs in the wiring diagrams 

in the service manual.

Regeneration Day Override Feature 

If the Day Override option is turned on and the valve reaches 

the set Regeneration Day Override value, the Regeneration 

Cycle starts if no other unit is in Regeneration. If other units 

are in regeneration, it is added to a regeneration queue. This 

occurs regardless of the remaining volume available.

WARNING:

 Transformer must be grounded and ground 

wire must be terminated to the back plate 

where grounding label is located before 

installation.

Fleck

 3200 NXT • 3

Содержание FLECK NXT TIMER

Страница 1: ...FLECK NXT TIMER SERVICE MANUAL waterpurification pentair com...

Страница 2: ...UPPER 2900S LOWER POWERHEAD ASSEMBLY 13 3150 3900 UPPER LOWER POWERHEAD ASSEMBLY 15 METER ASSEMBLY PLASTIC 17 1 INCH BRASS METER ASSEMBLY 18 1 INCH STAINLESS STEEL METER ASSEMBLY 19 1 1 2 INCH BRASS M...

Страница 3: ...operation CYCLE 1 00 00 00 BACK WASH Example 12 minutes remaining in Cycle 1 Backwash Press the Extra Cycle button during a system queued Regeneration Cycle to immediately advance the valve to the nex...

Страница 4: ...has left Standby and returned to Service When the Regeneration cycle is complete the regenerated unit will enter Standby Standby on each tank is controlled by the lower drive output terminals on the...

Страница 5: ...4 5 The third valves returns to stand by as demand decreases past the second trip point Standby Flow Split Between Two Meters 1 2 3 4 6 Valves return to stand by due to decreased total flow rate and...

Страница 6: ...CHG will be displayed when the lower drive changes from one state to another in dual piston valves INI Initializing INI will display on the screen for 30 to 45 seconds when initializing after a power...

Страница 7: ...e Transformer 1 Locate the ground label to find the screw to attach the ground wire on the transformer 2 Remove the screw and attach the ground wire and re attach the screw 3 Insert white and black tr...

Страница 8: ...nges press the Diagnostic button NOTE If no keypad activity is made for 5 minutes while in the Master Programming Mode or if there is a power failure no changes will be saved and the unit will go back...

Страница 9: ...time NOTE In U S Gallons mode the display will be in 12 hour time UNIT CAPACITY 00000000 GRAINS Options Grains in U S Format Default Grams in Metric Format Example Grains Default NOTE Use the Shift b...

Страница 10: ...nse 1 Hour Backwash 10 Minutes UF Fill First Brine Tank Fill 12 Minutes Brine Making 1 Hour Regenerant Flow Cycle 3 Time Cycle 4 Time Downflow Rapid Rinse 10 Minutes Brine Tank Fill 12 Minutes UF Brin...

Страница 11: ...ate at this time Example Peak flow since last regeneration Example Gallons at the outlet since installation Example Hours between the last regeneration and the one before it Example Hours since last r...

Страница 12: ...Start c c c c c c c c c c c c c c c c c c c c c Aux Relay Output End c c c c c c c c c c c c c c c c c c c c c Chemical Pump x x x x x x u u x x x x x x x x CPO Aux Relay Volume c c c c c c c c c c c...

Страница 13: ...ERHEAD ASSEMBLY 37 35 31 41 39 32 19 7 6 30 36 32 40 20 38 33 22 52 12 21 13 44 16 14 15 14 17 16 46 25 16 26 1 42 23 46 2 11 4 3 5 6 7 10 19 32 28 29 18 6 11 43 9 8 32 24 61501 3200NXT 2_Page2_REVA 2...

Страница 14: ...e 27 1 60217 02 Cover Assy 2900 Lower Black Environmental 28 1 18626 Spacer Indicator 29 1 18746 Bearing Connecting Rod 30 2 11224 Screw Hex Hd 5 16 18 X 5 8 Ss 31 1 10250 Ring Retaining 32 7 10872 Sc...

Страница 15: ...5 9 27 26 11 46 7 8 12 6 47 40 42 4 11 45 15 25 35 16 43 23 44 18 17 20 21 22 31 23 27 26 11 10 8 13 12 11 19 15 25 17 16 24 34 9 14 28 29 32 28 38 30 50 24 28 49 32 52 37 48 23 31 22 21 20 18 33 52 3...

Страница 16: ...0VA 41049 Transformer Euro 230V 24V 108VA 41050 Transformer Aust 230V 24V 108VA 36 1 19121 Meter Cable Assembly 19121 08 Meter Cable Assembly 35 inch long with connector 19121 09 Meter Cable Assembly...

Страница 17: ...1 1 2 BSP Plastic w O Ring 20 61560 Meter Assy 1 1 2 INLN ELEC PLAS w o Nipples TURB 61560 01 Meter Assy 1 INLN NPT ELEC PLAS PLAS Nipples TURB 61560 02 Meter Assy 1 INLN BSP ELEC PLAS PLAS Nipples T...

Страница 18: ...r 1 9 1 13287 O ring 123 10 1 14961 10 Fitting 1 Quick Connector BSP 11 1 14962 Nut Quick Connect NPT 12 1 60613 Meter Assy 1 Inline NPT Electronic Brass PDL 60613NP Meter Assy 1 Inline NPT Electronic...

Страница 19: ...tended Range 1 61932 20 Meter Assy 1 inch Inline Stainless Steel BSP Standard Range 1 61932 21 Meter Assy 1 inch Inline Stainless Steel BSP Extended Range 3 1 44022 Union 1 inch NPT Optional on models...

Страница 20: ...12 1 60614 Meter Assy 1 1 2 Inline NPT Electronic Brass Body PDL 60614NP Meter Assy 1 1 2 INLN NPT ELEC BRS BDY NP PDL 60614 01 Meter Assy 1 1 2 INLN NPT ELEC BRS BDY PDL 1 SLV 60614 01NP Meter Assy...

Страница 21: ...1 2 inch Inline Stainless Steel BSP Standard Range 1 61933 21 Meter Assy 1 1 2 inch Inline Stainless Steel BSP Extended Range 3 1 44024 Union 1 1 2 inch NPT Optional on models with electronic controls...

Страница 22: ...NP Fitting Nipple 2 BSP Brass NP 14 1 14679 O ring 227 15 1 14569 Nut Quick Connect 16 60615 Meter Assy 2 INLN NPT ELEC BRS PDL 1 5 SLV 60615NP Meter Assy 2 INLN NPT ELEC NP PDL 1 5 SLV 60615 20 Meter...

Страница 23: ...el BSP Standard Range 1 61934 21 Meter Assy 2 inch Inline Stainless Steel BSP Extended Range 3 1 44026 Union 2 inch NPT Optional on models with electronic controls 1 44027 Union 2 inch BSP Optional on...

Страница 24: ...Flow Straightener 11 8 40118 Screw SCKT HD 1 2 13 UN 12 8 16386 Nut Hex Jam 1 2 13 18 8 S S 13 6 12473 Screw Hex Washer Head 10 24 x 0 625 14 60617 Meter Assy 3 INLN NPT Electronic BRS BDY Paddlewhee...

Страница 25: ...ange 61935 11 Meter Assy 3 Inch Inline Stainless Steel NPT Extended Range 61935 20 Meter Assy 3 Inch Inline Stainless Steel BSP Standard Range 61935 21 Meter Assy 3 Inch Inline Stainless Steel BSP Ext...

Страница 26: ...NAL SOLENOID VALVE ON DURING REGENERATION OR STANDBY P6 OUTPUT 24VAC 50 60Hz 0 25 A MAX OPTIONAL INTERLOCK SWITCH N O UNSWITCHED HOT 24VAC 3A MAX RESISTIVE 30VDC 3A MAX RESISTIVE NEUTRAL SWITCHED HOT...

Страница 27: ...H N O 24VAC 3A MAX RESISTIVE 30VDC 3A MAX RESISTIVE SWITCHED HOT BLACK ORANGE RED WHITE BLACK C N O N C SW 4 GREEN LDCAM LDM RED BLACK WHITE GREEN LOWER DRIVE UPPER DRIVE BLACK RED GREEN OPTIONAL MOTO...

Страница 28: ...WHITE STRIPE RED WHITE STRIPE GREEN WHITE STRIPE WHITE BLACK STRIPE RED BLACK STRIPE BLUE BLACK STRIPE BLUE WHITE STRIPE GREEN 3 19 13 14 2 8 17 15 12 11 1 18 16 4 5 CONNECTOR FRONT VIEW BELDEN 9458...

Страница 29: ...DM 13 14 15 16 17 18 19 12 11 10 9 8 4 5 6 7 1 2 3 BLK TAN PINK BLUE HOME P N 19781 NOT USED UDM LINE RED BLACK BLACK IC1 RED GREY METER STEP AUX LDM WHITE GREEN WHITE RED BLACK 5 VDC BLACK NOT USED 9...

Страница 30: ...T NEUTRAL 250VAC 3A MAX RESISTIVE 30VDC 3A MAX RESISTIVE HCAM SCAM C N O N C SW1 C N O N C SW2 UDM 13 14 15 16 17 18 19 12 11 10 9 8 4 5 6 7 1 2 3 LDM LDCAM C N O N C SW4 BLK TAN PINK BLUE HOME P N 19...

Страница 31: ...EUTRAL 250VAC 3A MAX RESISTIVE 30VDC 3A MAX RESISTIVE BLACK P N 19781 9 6 3 FLOW METER 5 VDC DC GROUND 7 8 4 1 5 2 OPTIONAL SHIELD TB2 ORANGE OPTIONAL OPTIONAL SENSOR INPUT METER INPUT GREEN RED LOCKO...

Страница 32: ...50VAC 3A MAX RESISTIVE 30VDC 3A MAX RESISTIVE P N 19781 9 6 3 FLOW METER 5 VDC DC GROUND 7 8 4 1 5 2 OPTIONAL SHIELD TB2 ORANGE OPTIONAL OPTIONAL SENSOR INPUT METER INPUT GREEN RED LOCKOUT INPUT SENSO...

Страница 33: ...valve address number Program each unit with unique valve address number in Master Programming Detected Error Program Mismatch Master program parameters do not match between two or more controls Confi...

Страница 34: ...34 Fleck 3200 NXT...

Страница 35: ...Fleck 3200 NXT 35...

Страница 36: ...RPURIFICATION PENTAIR COM CUSTOMER CARE 800 279 9404 tech support pentair com For a detailed list of where Pentair trademarks are registered please visit waterpurification pentair com brands Pentair t...

Отзывы: