![Pentair FLECK 5810 XTR2 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/pentair/fleck-5810-xtr2/fleck-5810-xtr2_service-manual_1524456016.webp)
Parameter
Description
Flow Rate
Displays the current flow rate.
Peak Flow
Displays maximum flow rate of water along
with date and time of occurrence, since last
reset.
Totalizer
Displays total volume of water used since
last reset.
Last Regen
Displays when last regeneration occurred.
Reserve
Displays the reserve volume based on the
reserve type selected under master settings.
*This parameter is only available for meter
delayed regeneration type.
Software Version
Displays the software version installed on
the controller.
No of Regens
Displays how many manually and system
initiated regenerations the system has gone
through since last reset.
Regen Interval
Displays the average length of time between
regenerations based on the past four
regenerations.
Daily Usage
Displays average water usage for each day of
the week based on the usage on that day for
the past six weeks.
Usage Since Regen
Displays water usage since last regeneration.
Last Setting Change
Displays the date and time of the last update
to Master Settings.
NOTE: Only Peak Flow and Totalizer can be changed - they
can be reset to zero.
NOTE: Totalizer has a maximum value of 99,999,999. If this
number is reached, the Totalizer must be reset to zero
to continue tracking this value.
USB Connection for Field Programming
The XTR2 features a USB port that allows you to connect a PC
to the control for field programming and diagnostic parameter
download.
NOTE: Field Programmer software is required for field
programming features. See XTR2 Field Programmer
Manual for more information on using the Field
Programmer software.
Pressing on the Format screen displays the USB screen.
Figure 33 USB Screen
When the USB screen appears, connect a USB cable to the
USB port on the control circuit board. Connect the other
end of the USB cable to a PC with the Field Programmer
software installed and follow the directions in the XTR2 Field
Programmer manual to complete the connection. Press to
return to Master Settings.
NOTE: Do not remove USB cable from computer or control
while connected and transferring data. See the XTR2
Field Programmer manual for proper disconnection
procedure.
16 •
FLECK
5810 & 5812 XTR2 Service Manual