User Guide Fleck 5800-LXT
Ref. MKT-UG-005 / A - 09.12.2016
7 / 28
EN
Regeneration time
Note:
Determine the time of regeneration.
Water Hardness or number of days between regenerations
Note:
Determine the water hardness in mgl.(metered) or the number of days between regenerations (time clock).
4.2.
Diagnostic mode
To access the recorded informations, press MODE and
simultaneously for 5 seconds. Press
to see the data. Press
MODE twice to see the next diagnostic. Press
to exit the diagnostic mode.
5 .
Operation
5.1.
Recommendations
• Use only regenerate salts designed for water softening EN973;
• For optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• Do not use ice melt, block, or rock salts;
• The sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the
lifetime of the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on
the system.
5.2.
Manual immediate regeneration
6 .
Error codes
The following error codes may be displayed during operation:
7 .
Maintenance
Mandatory:
Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
8 .
Troubleshooting
Please follow this procedure for any technical support:
A
Collect the required information for a technical assistance request.
→
Product identification (see 2.1. Safety tags location, page 5 and Original settings, page 2).
B
Contact your local dealer who installed this device (see contact details on last page).
→
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
A
Press MODE until display position point to the Time of Regeneration icon.
B
Press and hold
or
until the Programming icon appears.
C
Set the time with
or
.
D
Press MODE to go to the next parameter, or press
to validate the selection and return to the
service mode.
A
Press MODE until display position point to the Hardness or Days between
regenerations icon.
B
Press and hold
or
until the Programming icon appears.
C
Set the water hardness or the number of days between regenerations with
or
.
D
Press MODE to go to the next parameter, or press
to validate the selection and return to the
service mode.
A
Press and hold
for 5 seconds.
---0
Cam sense error:
Unplug the unit and plug it back. If error continue, call technical support.
---1
Cycle sense error:
Unplug the unit and plug it back. If error continue, call technical support.
---2
Regen failure:
Perform a manual regeneration. If error continue, call technical support.
---4
Fail safe error:
Unplug the unit and plug it back. If error continue, call technical support.
A
A
A
Содержание Fleck 5800 LXT
Страница 1: ...Fleck 5800 LXT ...