background image

VALVE ASSEMBLIES

BLFC

60022-12

 .....................

BLFC, 0.125 GPM (0.375 lbs NaCl/min)

60022-25

 ....................

BLFC, 0.25 GPM (0.75 lbs NaCl/min)

60022-50

 ....................

BLFC, 0.50 GPM (1.5 lbs NaCl/min)

60022-100

 ...................

BLFC, 1.0 GPM (3 lbs NaCl/min)

Injector Assemblies

18272-000

 ...................

Injector Assy, 1610, #000, BROWN

 

(8" Tank)

18272-00

 .....................

Injector Assy, 1610, #00, VIOLET

 

(9" & 10" Tank)

18272-0

 .......................

Injector Assy, 1610, #0, RED

 

(12" & 13" Tank)

18272-1 ........................

Injector Assy, 1610, #1, WHITE

 

(14" & 16" Tank)

18272-2 .......................

Injector Assy, 1610, #2, BLUE

 

(18" Tank)

18272-3 .......................

Injector Assy, 1610, #3, YELLOW

 

(20" Tank)

Powerheads

44553-00

 ....................

Powerhead Assy, 5000

Timer

44552 ..........................

Timer Assy, 5000

Meter Assemblies

60086-50

 ....................

Meter Assy, 3/4" Dual Port, Slip Elec, Plas, 
Pdl, w Clps

60626

 ..........................

Meter Assy, Turbine, Electronic 3/4" with 
Clips and Screws

Meter Cables

19121-01

 .......................

Meter Cable Assy, SE, Paddle

19791-01

 .......................

Meter Cable Assy, Turbine/SXT

Misc.

40947-02

 ....................

Plug, Brine Valve, with o-rings

13918-01

 .......................

BLFC Module Plug Assy, with o-rings

B

A

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

Pentair Residential

Filtration, LLC

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

INJECTOR ASSY, #1, WHITE

5000/5800

18272-1

A

2:1

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

B

2

1

F

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

  ANGLES :       1

  1 PLACE  .X:    .015  [0.38]

  2 PLACE  .XX:    .01  [0.3]

  3 PLACE  .XXX:   .005  [0.13]

BR42886

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENT

CHECKED

20

16

13

14

14

15

15

11

10

9

2

5

12

8

4

3

2

1

6

17

18

7

272481

A

RELEASE FOR PRE-PRODUCTION

44553-00

5000

44553-01

50DP

12-9-12 PWS

ITEM NO.

PART 

NUMBER

DESCRIPTION

44553-

00/QTY.

44553-

01/QTY.

1

BR14044

TIE, CABLE, PLASTIC

1

1

2

13296

SCREW, HEX WASHER, 6-20 X 1/2

5

5

3

18259-02

COVER,BACK,BLACK

1

1

4

13602

SCREW,PHIL RD HD,6-32 X 5/16 

2

2

5

13547

STRAIN RELIEF, ROUND CORD

1

1

6

19474

HARNESS,POWER,5600SE,ELECT

1

-

7

19474-01

 HARNESS, POWER,8500SE/4200SE

-

1

8

40251

MOTOR, 24V - 50/60HZ

1

1

9

18202

BACK PLATE

1

1

10

18228

CAM, BRINE VALVE

1

1

11

18211-01

GEAR, MAIN, DOWNFLOW, MACHD

1

1

12

18655

PIN,ROLL,3/32 X 1/2

1

1

13

19927

CAM, RAYNE, D/F, SE

1

1

14

10218

2

2

15

17876

SCREW,PHIL PAN,4-40X1 1/8

2

2

16

40269

PLATE,FRONT

1

1

17

40422

NUT, WIRE, TAN

4

4

18

44147

TRANSFORMER, 24V,9.6VA

1

1

19

BR16618

BAG, POLY, 8"X4"X12", 1.5 MIL

1

1

20

40326

LABEL,COVER-UP,PROFLOSE

1

-

B

A

1

3

4

4

3

2

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

PWRHD ASSY, 5000 AC-SXT

44553

D

1:8

PS

5

5

D

C

6

7

8

6

7

8

B

C

D

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

A.01

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

    

ANGLES :       1

  1 PLACE  .X:    .015  [0.38]

  2 PLACE  .XX:    .01  [0.3]

  3 PLACE  .XXX:   .005  [0.13]

BR42889

12/10/2019

Pentair Residential

Filtration, LLC

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

272481

A

RELESE FOR PRE-PRODUCTION

12-9-19 PWS

ITEM NO.

PART NUMBER

DESCRIPTION

QTY.

1

BR42635-01

1

2

BR42637

LABEL, DISPLAY,SE

1

3

44098U

CIRCUIT BOARD, SXT AC, UNPRGM

1

B

A

B

1

3

4

4

3

2

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

Pentair Residential

Filtration, LLC

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

TIMER ASSY, AC-SXT 5000

44552

B

1:2

PS

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

A.01

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

    

  ANGLES :     

 1

  1 PLACE  .X:  

 .015  [0.38]

  2 PLACE  .XX:  

 .01  [0.3]

  3 PLACE  .XXX: 

 .005  [0.13]

BR42887

12/10/2019

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

BLFC (3/8")

INJECTOR ASSY

POWERHEAD

METER ASSY

BLFC (1/2")

TIMER ASSY, SXT

METER CABLE ASSY

PENTAIR FLECK 5000 Control Valve Service Manual 

• 

17

Содержание FLECK 5000

Страница 1: ...pentair com FLECK 5000 CONTROL VALVE SERVICE MANUAL...

Страница 2: ...0626 18 Paddle Meter Assembly P N 60086 50 18 Bypass Valve Assembly Metal 19 Bypass Valve Assembly Plastic 19 Safety Brine Valve 20 Dimensional Drawings 21 Water Conditioner Flow Diagrams 22 Injector...

Страница 3: ...Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot Water Outlet Water Heater Brine Tank Overflow Drain Optional Floor Drain Drain Line Bypass Softener Grounding Strap Figur...

Страница 4: ...hypochlorite 70 available chlorine is available in several forms including tablets and granules These solid materials may be used directly without dissolving before use 1 Dosage A Two grains approxima...

Страница 5: ...13 mm Backwash flow rates in excess of 7 gpm 26 5 Lpm or length in excess of 20 feet 6 m require 3 4 inch 19 mm drain line Commercial drain lines should be the same size as the drain line flow control...

Страница 6: ...Indicator Service Icon Programming Icon Extra Cycle Button Up Button Down Button Error Information Icon Features of the SXT Power backup that continues to keep time and the passage of days for a mini...

Страница 7: ...normal operation Pressing the Extra Cycle button during a regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing Control Operation During Pro...

Страница 8: ...ety Factor Percentage of the system capacity to be used as a reserve RC Fixed Reserve Capacity Fixed volume to be used as a reserve DO Day Override The system s day override setting RT Regen Time The...

Страница 9: ...n entering Master Programming Mode The Display Format setting specifies the unit of measure that will be used for volume and how the control will display the Time of Day This option setting is identif...

Страница 10: ...MING MODE CONTINUED 9 Safety Factor Display Code SF Press the Extra Cycle button Use this display to set the Safety Factor This setting specifies what percentage of the system capacity will be held as...

Страница 11: ...ion for each day Use the Up and Down buttons to adjust the setting as needed Press the Extra Cycle button to accept the setting and move to the next day Note that the control requires at least one day...

Страница 12: ...ds while in service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press...

Страница 13: ...in service 2 Press the Up button Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button Use this disp...

Страница 14: ...r Downflow Softener U S Power Supply 1 Injector 0 50 GPM BLFC 500006 003 Turbine Meter B W Filter U S Power Supply NOTE NOTE Above part numbers DO NOT include the following parts Bypass Assembly Conne...

Страница 15: ...sher Head 10 24 0 81 9 1 13304 O ring 121 10 1 18303 01 O ring 336 560CD 11 1 13030 Retainer Distributor Tube O ring 12 1 18569 Retainer Tank Seal 13 1 18312 DLFC Housing Retainer Clip 14 1 60115 001...

Страница 16: ...4 Yoke SS NPT Washers 19153 Washer Flow 0 6 GPM 19152 Washer Flow 0 8 GPM 12085 Washer Flow 1 2 GPM 19150 Washer Flow 1 3 GPM 12086 Washer Flow 1 5 GPM 12087 Washer Flow 2 0 GPM 12088 Washer Flow 2 4...

Страница 17: ...REQUIREMENT CHECKED 20 16 13 14 14 15 15 11 10 9 2 5 12 8 4 3 2 1 6 17 18 7 272481 A RELEASE FOR PRE PRODUCTION 44553 00 5000 44553 01 50DP 12 9 12 PWS ITEM NO PART NUMBER DESCRIPTION 44553 00 QTY 445...

Страница 18: ...Item No QTY Part No Description 1 1 14716 Meter Cap Assy NT includes items 2 3 and 4 2 1 13874 Cap Meter Electronic 3 1 13847 O ring 137 Std Meter 4 1 17798 Screw Slot Hex Washer Head 5 1 19121 01 Met...

Страница 19: ...Yoke 1 BSP Plastic 41027 02 Yoke 3 4 BSP Cast Machined 18706 12 Yoke 3 4 BSP Plastic 19620 01 Yoke Assy 3 4 R Angle 90 Deg 6 1 60049 Bypass Plastic Not Shown 2 19228 01 Adapter Assy Coupling w O ring...

Страница 20: ...9647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 Plastic 10 1 18312 Retainer Drain 11 1 60014 Safety Brine Valve Assy 2310 12 2 10150 Grommet 0 30 Dia 13 1 60068 30 Float Assy 2310 w 30 Rod 14 1 6...

Страница 21: ...DIMENSIONAL DRAWINGS PENTAIR FLECK 5000 Control Valve Service Manual 21...

Страница 22: ...neral in the mineral tank Conditioned water enters center tube through the bottom distributor then flows up through the center tube and to the outlet of the valve Hard water enters unit at valve inlet...

Страница 23: ...ough nozzle and throat down through mineral and enters the center tube through bottom distributor and out through the drain line Hard water flows from inlet around the piston down through the mineral...

Страница 24: ...TR18755 Rev B 24 PENTAIR FLECK 5000 Control Valve Service Manual INJECTOR FLOW DATA...

Страница 25: ...BLACK ORANGE WT BLK BLACK WHITE GREEN BLUE BLUE WHITE BLUE WHITE BLUE PURPLE ORANGE BLACK WT BLK YELLOW BLACK BROWN METER P1 S N N H S VDO P2 N O H PWR H S CB1 50 60 HZ CB1 SXT Timer T1 24V Transforme...

Страница 26: ...upport pentair com PENTAIR COM All indicated Pentair trademarks and logos are property of Pentair Third party registered and unregistered trademarks and logos are the property of their respective owne...

Отзывы: