Page 4

Installation Instructions

WATER PRESSURE:

 A minimum of 20 pounds of water pressure (1.4 bar) is required for regeneration valve to operate 

effectively.

ELECTRICAL FACILITIES:

 An uninterrupted alternating current (A/C) supply is required. Note: Other voltages are available. 

Please make sure your voltage supply is compatible with your unit before installation.

EXISTING PLUMBING:

 Condition of existing plumbing should be free from lime and iron buildup. Piping that is built up heavily 

with lime and/or iron should be replaced. If piping is clogged with iron, a separate iron filter unit should be installed ahead of 
the water softener.

LOCATION OF SOFTENER AND DRAIN:

 The softener should be located close to a drain to prevent air breaks and back flow.

BY-PASS VALVES:

 Always provide for the installation of a by-pass valve if unit is not equipped with one.

CAUTION:

 Water pressure is not to exceed 125 psi (8.6 bar), water temperature is not to exceed 110°F (43°C), and the unit 

cannot be subjected to freezing conditions.

Installation Instructions

Place the softener tank where you want to install the unit making sure the unit is level and on a firm base.

1. 

During cold weather, the installer should warm the valve to room temperature before operating.

2. 

All plumbing should be done in accordance with local plumbing codes. The pipe size for residential drain line should be a 

3. 

minimum of 1/2” (13 mm). Backwash flow rates in excess of 7 gpm (26.4 Lpm) or length in excess of 20’ (6 m) require  
3/4” (19 mm) drain line. Commercial drain lines should be the same size as the drain line flow control. 

Refer to the dimensional drawing for cutting height of the distributor tube. If there is no dimensional drawing, cut the 

4. 

distributor tube flush with the top of the tank.

Lubricate the distributor O-ring seal and tank O-ring seal. Place the main control valve on tank. 

5. 

Note: Only use silicone lubricant.

Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting 

6. 

(DLFC). Leave at least 6” (15 cm) between the DLFC and solder joints when soldering pipes 
that are connected on the DLFC. Failure to do this could cause interior damage to the DLFC.

Teflon tape is the only sealant to be used on the drain fitting. The drain from twin tank units may 

7. 

be run through a common line.

Make sure that the floor is clean beneath the salt storage tank and that it is level.

8. 

Place approximately 1” (25 mm) of water above the grid plate. If a grid is not utilized, fill to the 

9. 

top of the air check (Figure 1) in the salt tank. Do not add salt to the brine tank at this time.

On units with a by-pass, place in by-pass position. Turn on the main water supply. Open a cold 

10. 

soft water tap nearby and let run a few minutes or until the system is free from foreign material 
(usually solder) that may have resulted from the installation. Once clean, close the water tap.

Slowly place the by-pass in service position and let water flow into the mineral tank. When water 

11. 

flow stops, slowly open a cold water tap nearby and let run until the air is purged from the unit.

Plug unit into an electrical outlet. Note: All electrical connections must be connected according 

12. 

to local codes. (Be certain the outlet is uninterrupted).

60002-34REVC

Figure 1 Residential 
Air Check Valve

Содержание FLECK 2750 Downflow

Страница 1: ...Model 2750 Down ow Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...

Страница 2: ...ents IMPORTANT PLEASE READ The information speci cations and illustrations in this manual are based on the latest information available at the time of printing The manufacturer reserves the right to m...

Страница 3: ...750 gallon setting K Electronic________ Pulse Count ________ Meter Size 4 System Type A System 4 1 Tank 1 Meter Immediate or Delayed Regeneration B System 4 Time Clock C System 4 Twin Tank D System 5...

Страница 4: ...ould be the same size as the drain line ow control Refer to the dimensional drawing for cutting height of the distributor tube If there is no dimensional drawing cut the 4 distributor tube ush with th...

Страница 5: ...er operation section If the valve came with a separate electronic timer service manual refer to the timer operation section of the electronic timer service manual Position the valve to backwash Ensure...

Страница 6: ...ing approximately three hours and stop in the position shown in the drawing 4 Even though it takes three hours for this center knob to complete one revolution the regeneration cycle of your unit might...

Страница 7: ...ent of the manual regeneration 2 knob engages the program wheel and starts the regeneration program The black center knob will make one revolution in the following approximately three hours and stop i...

Страница 8: ...pins as required The number of pins times two equals the backwash time in minutes How To Change The Length Of Brine And Rinse Time The group of holes between the last pin in the 1 backwash section and...

Страница 9: ...Page 9 Notes...

Страница 10: ...Page 10 3200 Timer Assembly 61502 3200_REVA For Service Assembly Numbers See the Back of this Manual...

Страница 11: ...24V 60Hz 1 30 RPM 16 2 13278 Screw Sltd Fillister Hd 6 32 x 156 17 1 15424 Spring Detent Timer 18 1 15066 Ball 1 4 Delrin 19 1 15465 Label Caution 20 1 19210 Program Wheel Assy 21 1 13911 Gear Main D...

Страница 12: ...Page 12 3210 Timer Assembly 61502 3210_REVA For Service Assembly Numbers See the Back of this Manual...

Страница 13: ...7 1 13887 Plate Motor Mounting 18 1 18743 1 Motor 120V 60Hz 1 30 RPM 5600 19 1 13278 Screw Fillister Hd 6 32 x 156 20 1 13830 Pinion Program Wheel Drive 21 1 13831 Clutch Drive Pinion 22 1 14276 Sprin...

Страница 14: ...Page 14 For Service Assembly Numbers See the Back of this Manual Powerhead Assembly Designer 61502_2510REVB...

Страница 15: ...ing 13 1 10621 Connecting Link 14 1 12576 Drive Cam STF Black 15 2 10338 Roll Pin 16 1 13366 Drive Bearing 17 2 14923 Screw Switch Mounting 18 1 41543 Motor Drive 115V 50 60Hz 42579 Motor Drive 24VAC...

Страница 16: ...Page 16 Environmental Powerhead Assembly For Service Assembly Numbers See the Back of this Manual...

Страница 17: ...nsulator Limit Switch 11 2 10218 Switch Micro 12 2 14923 Screw Pan Hd Mach 4 40 x 1 13 2 12777 Cam Shut Off Valve 14 1 10909 Pin Link Not Shown 1 15513 Meter Cable 17 50 1 15441 Cable Guide Assy 2750...

Страница 18: ...4 1 12707 Washer Spring 6 1 11235 Nut Hex 1 4 20 Mach Screw Zinc 7 1 12594 Lever Valve Position 8 2 10231 Screw Slot Hex 1 4 20 x 1 2 18 8 S S 9 1 60224 32 Cover Assy Manual Filter 1 60224 33 Cover A...

Страница 19: ...Page 19 Notes...

Страница 20: ...Page 20 Control Valve with 1700 Injector For Service Assembly Numbers See the Back of this Manual...

Страница 21: ...00 15 1 11893 Cap Injector Stainless Steel 10228 Cap Injector Brass 16 2 14804 Screw Hex Hd Mach 10 24 x 2 3 4 17 1 Washer Flow Control specify size 18 1 60365 00 Housing DLFC 1 2 F x 3 4 F 19 2 11710...

Страница 22: ...ve Stem 14 1 10249 Spring Brine Valve 15 1 12550 Quad Ring 009 16 1 12748 Brine Valve Body Assy 1600 w Quad Ring 17 1 12552 02 Brine Valve Stem 1600 w Seat 18 1 12626 Seat Brine Valve 19 1 11982 O rin...

Страница 23: ...1 60010 50 BLFC 1650 50 GPM Plastic 1 60010 100 BLFC 1650 1 0 GPM Plastic 15 1 16508 01 Tube Brine Valve 2850 1600 1 40027 Tube Brine Valve 2510 1 42184 Tube Brine Valve 2850s 1 12774 Tube Brine Valve...

Страница 24: ...Page 24 1700 Series Brine System Assembly For Service Assembly Numbers See the Back of this Manual...

Страница 25: ...Insert 1 2 Tube 15 2 15414 Nut 2900 w Sleeve 16 1 15413 Fitting Elbow Male 1 2T x 3 8 NPT 17 1 15416 Tube Brine 2900 2750 1 16460 Tube Brine 2850 2900s 1 41447 Tube Brine 2900s U F 1 42183 Tube Brine...

Страница 26: ...32 X 5 16 15 2 41056 Nut Assembly 1 2 Plastic 18 1 15414 Nut 2900 w Sleeve 19 1 15415 Fitting Insert 1 2 Tube 20 1 16460 Tube Brine 2850 2900s 1 42183 Tube Brine 1700 2850s 1 15416 Tube Brine 2900 275...

Страница 27: ...ss Hot Water 5B 1 15237 Meter Cap Assembly Ext Brass Hot Water 6 4 12112 Screw Hex Hd Mach 10 24 x 1 2 7 1 14960 Flow Straightener 1 8 1 13287 O ring 123 9 1 14961 Fitting 1 Quick Connect 10 1 14962 N...

Страница 28: ...ing 009 5 1 10785 Service Valve Operator Body Assembly Brass Valves 6 1 12552 Brine Valve Stem 1600 7 1 12626 Seat Brine Valve 8 3 10332 Fitting Insert 3 8 9 3 10330 Fitting Sleeve 3 8 Celcon 10 3 103...

Страница 29: ...ert 3 8 9 5 10330 Fitting Sleeve 3 8 Celcon 10 5 10329 Fitting Tube 3 8 Nut Brass 11 1 10328 Fitting Elbow 90 Deg 1 4 NPT x 3 8 Tube 12 2 12897 Tube Fitting 3 8 x 9 3 4 13 1 16730 Fitting Male 1 4 x 1...

Страница 30: ...Nut Hex 10 24 Nylon Black 5 1 19652 01 Poppet Assy SBV w O Ring 6 1 19649 Flow Dispenser 7 1 11183 O ring 017 8 1 19647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 Plastic 10 1 18312 Retainer Drai...

Страница 31: ...Page 31 Notes...

Страница 32: ...ing B Excessive water in brine tank B See problem 7 4 Loss of water pressure A Iron buildup in line to water conditioner A Clean line to water conditioner B Iron buildup in water condi tioner B Clean...

Страница 33: ...ram and positioning of control Replace power head assem bly if not positioning properly B Foreign material in control B Remove power head assembly and inspect bore Remove foreign material and check co...

Страница 34: ...Page 34 Water Conditioner Flow Diagrams...

Страница 35: ...Page 35 Water Conditioner Flow Diagrams...

Страница 36: ...Page 36 Flow Data Injector Draw Rates...

Страница 37: ...Page 37 System 4 Typical Tank Installation with Optional Meter System 5 Interlock Typical Twin Tank Installation with Optional 2 Meter Interlock and No Hard Water Bypass...

Страница 38: ...Page 38 System 6 Twin Series Regeneration Installation with a Remote Meter System 7 Twin Alternator Installation with a Remote Meter...

Страница 39: ...Page 39 System 4 Immediate Delayed Valve Wiring 19201_REVB...

Страница 40: ...Page 40 System 4 Remote Signal Start Valve Wiring 13768_REVG...

Страница 41: ...Page 41 System 5 Duplex Valve Wiring 40502 01_REVB 40502 02_REVB...

Страница 42: ...Page 42 System 6 Duplex Valve Wiring 13632 01_REVK 13632 02_REVL...

Страница 43: ...Page 43 System 7 Duplex 24V 120V 3 Way Valve Wiring 19138 01_REVD 19138 02_REVD...

Страница 44: ...Page 44 System 7 Duplex 230V 3 Way Valve Wiring 17727 01_REVD 17727 02_REVD...

Страница 45: ...Assembly 60381 xx 1700 Injector Assembly 60486 xx 1700 Injector Assembly xx is for the size injector used Meters 60391 2750 Meter Assy Std Plastic Cap 60392 2750 Meter Assy Ext Plastic Cap Covers 6023...

Страница 46: ...P N 42327 Rev B 9 30 08...

Отзывы: