Troubleshooting
Problem
Cause Correction
8. Softener fails to draw brine.
A. Drain line flow control is
plugged.
A. Clean drain line flow control.
B. Injector is plugged.
B. Clean injector
C. Injector screen plugged.
C. Clean screen.
D. Line pressure is too low.
D. Increase line pressure to 20 psi.
E. Internal control leak
E. Change seals, spacers, and piston
assembly.
F. Service adapter did not cycle.
F. Check drive motor and switches.
9. Control cycles continuously.
A. Misadjusted, broken, or shorted
switch.
A. Determine if switch or timer is faulty
and replace it, or replace complete
power head.
10. Drain flows continuously.
A. Valve is not programming cor-
rectly.
A. Check timer program and positioning
of control. Replace power head assem-
bly if not positioning properly.
B. Foreign material in control.
B. Remove power head assembly and
inspect bore. Remove foreign material
and check control in various regeneration
positions.
C. Internal control leak.
C. Replace seals and piston assembly.
General Service Hints For Meter Control
Problem: Softener delivers hard water
Reason:
Reserve capacity has been exceeded.
Correction:
Check salt dosage requirements and reset program wheel to provide additional reserve.
Reason:
Program wheel is not rotating with meter output.
Correction:
Pull cable out of meter cover and rotate manually. Program wheel must move without binding
and clutch must give positive clicks when program wheel strikes regeneration stop. If it does not, replace
timer.
Reason:
Meter is not measuring flow.
Correction:
Check meter with meter checker.
Содержание FLECK 2750 Downflow
Страница 9: ...Page 9 Notes...
Страница 10: ...Page 10 3200 Timer Assembly 61502 3200_REVA For Service Assembly Numbers See the Back of this Manual...
Страница 12: ...Page 12 3210 Timer Assembly 61502 3210_REVA For Service Assembly Numbers See the Back of this Manual...
Страница 14: ...Page 14 For Service Assembly Numbers See the Back of this Manual Powerhead Assembly Designer 61502_2510REVB...
Страница 16: ...Page 16 Environmental Powerhead Assembly For Service Assembly Numbers See the Back of this Manual...
Страница 19: ...Page 19 Notes...
Страница 20: ...Page 20 Control Valve with 1700 Injector For Service Assembly Numbers See the Back of this Manual...
Страница 24: ...Page 24 1700 Series Brine System Assembly For Service Assembly Numbers See the Back of this Manual...
Страница 31: ...Page 31 Notes...
Страница 34: ...Page 34 Water Conditioner Flow Diagrams...
Страница 35: ...Page 35 Water Conditioner Flow Diagrams...
Страница 36: ...Page 36 Flow Data Injector Draw Rates...
Страница 39: ...Page 39 System 4 Immediate Delayed Valve Wiring 19201_REVB...
Страница 40: ...Page 40 System 4 Remote Signal Start Valve Wiring 13768_REVG...
Страница 41: ...Page 41 System 5 Duplex Valve Wiring 40502 01_REVB 40502 02_REVB...
Страница 42: ...Page 42 System 6 Duplex Valve Wiring 13632 01_REVK 13632 02_REVL...
Страница 43: ...Page 43 System 7 Duplex 24V 120V 3 Way Valve Wiring 19138 01_REVD 19138 02_REVD...
Страница 44: ...Page 44 System 7 Duplex 230V 3 Way Valve Wiring 17727 01_REVD 17727 02_REVD...
Страница 46: ...P N 42327 Rev B 9 30 08...