INSURICE PF SYSTEMS INSTALLATION AND OPERATION GUIDE
9. Remove the wrapping from a new EC210 prefilter
cartridge and insert the cartridge into the prefilter bowl
aligning the hole in the bottom of the cartridge over the
raised stub in the bottom of the bowl.
10. Check to see that the o-ring is in place at the top of the
prefilter bowl and that it is lubricated with food grade
silicone lubricant. Reinstall the bowl by aligning the hole
in the top of the cartridge with the stub extending down
from the housing head and threading the bowl onto the
head. Hand tighten snugly. Do not over-tighten the bowl.
11. Remove the wrapping from the new Insurice
filter cartridge(s).
12. Install the filter cartridge(s) into the filter manifold heads
following directions on the cartridge label.
13. Open the inlet water supply to the prefilter sub-assembly
and flush the cartridges by running water through the
system at full force for five minutes. This will purge any
air and fines and ensure maximum filter life.
14. Shut off the flushing valve and open any outlet valves
to equipment.
15. Restore the equipment to service.
NOTES
Check for compliance with state and local laws and
regulations. Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain
filterable cysts.
Not for residential use. For food service applications only.
REPLACEMENT PARTS
Contact your local Pentair
®
Everpure
®
dealer for filter
cartridges or system replacement parts.
CARTRIDGE CHANGE PROCEDURE
Everpure Carbon
Filter Cartridge
Change
1. Shut off power to
equipment. Shut
off inlet water
ahead of system.
2. Open flushing
valve to relieve
pressure.
3. Hold head firmly
and push upward.
Turn cartridge to
left until it stops.
4. Pull cartridge
downward and out
of head.
5. Hold head firmly.
Align cartridge lug
with label. Insert
new cartridge
firmly into head.
6. Turn cartridge
right 90˚ until
rotation stops.
7. Repeat steps 3-6
for remaining
cartridges.
Flushing
8. With flushing
valve fully open,
open inlet water at
full force for five
minutes. Close
flushing valve.
9. Turn on power to
equipment.
System Tested and Certified by NSF International against NSF/ANSI Standards 42 and 53 for
the reduction of:
Standard No. 42 — Aesthetic Effects
Standard No. 53 — Health Effects
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Cyst
Asbestos (i2000 and i2000
2
only)
Mechanical Filtration
Nominal Particulate Class I