background image

15

EQ Series Pump Installation and User’s Guide

Assembly

1. Ensure that the two 6 ½ in. long screws (11) with washers (12) are properly inserted into the bottom of the

motor adaptor (7) before attaching the motor adaptor (7) to the new motor (1).

2. Properly orient the motor adaptor (7) to the motor (1) and secure in place using the four screws (10) and

washers (8) (9).

3. Insert the two dowel pins (26) into the motor adaptor (7).
4. Install the stationary ring of the mechanical seal (14) into the seal plate bore. Ensure that it is fully inserted into

the bore with the white surface facing you.

 

CAUTION

 —

The mechanical seal is a highly engineered component that must be carefully handled. The contact
faces are manufactured to extremely precise tolerances. These faces must be free of all surface dust
and debris. Always wash your hands before handling the mechanical seal. Avoid touching the
contact faces except for when pressing the seal ring into the bore. Lubricate the rubber portion with
a slight amount of soapy water if required to insert it into the bore. Do not use silicone or other
lubricants as this can contaminate the seal face. Rinse the seal face if required after assembly to free
it of any dirt or debris.

5. Properly orient the seal plate (13), slip it onto the two dowel pins (26) and secure to the motor adaptor (7) by

tapping it toward the motor adaptor (7) until there is no clearance between the two parts.

6. Slip the spring portion of the mechanical seal (14) over the motor shaft, being certain that the hard black

contact surface is facing the white surface of the stationary seal ring. Use a small amount of soapy water if
required to lubricate the rubber of the mechanical seal (14) so that it slips easily over the shaft.

7. Install the shaft key     into the shaft of the motor and then install the impeller (15) over the shaft. It will be

necessary to align the keyway in the impeller (15) with the key     . Push the impeller (15) as far as possible
onto the motor shaft (1).

8. Install the socket head screw (16) with washers (4) (5) to secure the impeller (15). It is important that the

screw (16) be tightened securely and that the impeller (15) is fully seated.

9. Apply a light film of silicone grease to the inside diameter of the brass bushing inside the diffuser (17). This

film  will assist in properly centering the diffuser bushing to the impeller (15) and will reduce the  friction should
the parts contact during motor start-up.  DO NOT USE ANY OTHER TYPES OF LUBRICANTS.

10. Install the diffuser (17) over the impeller (15) and secure with the four screws (20), but only hand tight. The

diffuser (17) has clearance around the four screws (20) that will allow adjustment of the fit of the diffuser (17)
around the impeller (15) nose. Rotate the impeller (15) by hand to ensure that it is free to turn and slowly tighten
each of the four screws (20). Verify that the impeller (15) is free to turn once the diffuser screws (20) are fully
tightened.

11. Lubricate the diffuser O-Ring (21) and the larger seal plate O-Ring (28) with silicone lubricant or Murphy

®

 Oil

Soap. This will allow the O-Rings to slip into place without getting pinched. Ensure that the big seal plate
O-Ring (28) is properly seated on the large diameter of the seal plate (13).

12. Carefully slip the motor end assembly into the housing (22) pushing it forward as far as possible until the large

seal plate O-Ring (28) comes into contact with the housing (22). Insert the four 6½ in. long screws (11) through
the housing (22) and secure the assembly in place using the washers (12) and nuts (23).  Gradually tighten each
of the four screws a few turns in a crossing pattern to ensure that the motor assembly is properly centered to
the housing. 

 

Do not over tighten these screws.

 

CAUTION

 —

Failure to follow the above assembly procedures could cause the impeller to bind once the pump is
fully assembled. It is possible to remove the strainer basket, reach through the strainer pot and spin
the impeller to verify that it will rotate freely.  A bound impeller may cause the motor to not start or
cause the motor to draw excessive amps.

13. Secure the motor (1) to the motor supports (2).
14. Reconnect the ground and supply conductors.
15. Read and follow the instructions under Section 4, Initial Operation of Pump before putting the pump back into service.

1

1

Содержание EQ SERIES

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide EQ SERIES High Performance Commercial Pump...

Страница 2: ...their products Pentair Water Pool and Spa Inc disclaims any proprietary interest in trademarks and trade names other than its own P N 350061 Rev E 1 24 06 Customer Service If you have questions about...

Страница 3: ...re Testing 5 Section 3 Electrical Requirements 7 Electrical Requirements and Field Wiring 7 Section 4 Initial Operation of Pump 9 Priming the EQ Series Pump 9 Section 5 Maintenance 11 Cleaning the Str...

Страница 4: ...ate the pump until you have read and understand clearly all the operating instructions and warning messages for all equipment that is a part of the pool circulating system The following instructions a...

Страница 5: ...could cause severe personal injury or death if they were to strike a person WARNING Due to the potential risk that can be involved it is recommended that the pressure test be kept to the minimum time...

Страница 6: ...suction plumbing be installed in accordance with the latest national and local codes for swimming pools These instructions contain information for a variety of pump models and therefore some instruct...

Страница 7: ...wosignificant benefits First it means more efficient performance the EQ pump moves more water more quickly than comparable pumps And secondly it means the pump s motor doesn t have to work as hard and...

Страница 8: ...ovides true breakthrough performance Lower load due to efficient impeller design means longer motor life Cam and Ramp lid design with clear lid for added convenience in servicing Additional Features C...

Страница 9: ...ipeespecially on the suction line to keep flow velocities at or below 6 feet per second fps Flow velocities in the return plumbing should not exceed 10 fps Also keep elbows and tees to a minimum Insta...

Страница 10: ...he pump CAUTION On installations where the pump is installed without a strainer pot use only 6 in Schedule 40 PVC pipe when making the final flange connection Do NOT use Schedule 80 Pipe as this can c...

Страница 11: ...signed to meet the local code test pressure Most components should be marked with a maximum operating pressure If a component is not marked consult the Owner s Instructions that came with the componen...

Страница 12: ...t of that part of the system 8 Allow the pressure to slowly build once all of the air openings are closed Close the valve between the water supply and circulation system to isolate the system from the...

Страница 13: ...integrity WARNING Risk of electrical shock or electrocution This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Elect...

Страница 14: ...ate information on the pump 5 Following the National Electrical Code and any local electrical codes connect the grounding conductor and electrical supply conductors to the motor Ensure that the pump i...

Страница 15: ...p 5 The pump will experience a temporary unstable condition as water and air flow through the pump During this unstable condition the pump may be noisy and produce erratic flow If the pump is below or...

Страница 16: ...10 EQ Series Pump Installation and User s Guide...

Страница 17: ...G If the pump has been energized for a period greater than 45 minutes without water flowing through the pump for any reason the water in the strainer pot may be hot Attempting to remove the locking ri...

Страница 18: ...motor is designed to carry the pump load without building up excessive heat An increase in normal operating temperatures may indicate a potential problem Athermocoupleplacedatthemotorventilationdischa...

Страница 19: ...ng instructions before working on the pump Thepumpisdesignedtoallowforquickservicingofanymovingpartswithoutdisturbingtheplumbing connections The pump can be serviced with the common tools that are in...

Страница 20: ...ternal components Ifdesired thesupplyconductorscanbedisconnectedandthemotorendassemblycanbetakentoaworkbench for easier service 10 Remove the four screws 20 with washers 18 19 that secure the diffuser...

Страница 21: ...d screw 16 with washers 4 5 to secure the impeller 15 It is important that the screw 16 be tightened securely and that the impeller 15 is fully seated 9 Apply a light film of silicone grease to the in...

Страница 22: ...ged Closed Valve in Piping System Air leak in Suction Line Pump installed more than 10 ft above Water Level or otherwise too high for Hydraulic Conditions of Pool Plumbing System Pump Shaft rotating i...

Страница 23: ...s EQ300 EQ500 EQ750 3PH qty 4 7 356790 Adapter Motor EQ Series 8 075842 Washer Flat ID x 1 OD 125 Thk 300 s s qty 4 9 350063 Washer Split Lock 1 2 18 8 s s qty 4 10 354290 Screw 3 8 16 x 1 Hx Hd Cap 1...

Страница 24: ...HZ EQK500 50HZ METERS OF WATER CUBIC METERS PER HOUR 0 5 10 15 20 0 25 50 75 100 125 150 175 FLOW RATE IN U S GPM 0 20 40 60 80 100 120 0 100 200 300 400 500 600 700 800 900 FLOW RATE IN U S GPM TOTAL...

Страница 25: ...PUMPEQW300 1PH6 x4 PUMPEQW300 3PH6 x4 PUMPEQW500 1PH6 x4 PUMPEQW500 3PH6 x4 PUMPEQ500 1PH6 x4 PUMPEQ500 3PH6 x4 PUMPEQ750 1PH6 x4 PUMPEQ750 3PH6 x4 PUMPEQ1000 3PH6 x4 PUMPEQ1500 3PH6 x4 PUMPEQK300 50...

Страница 26: ...P FOR 6 STD FLANGE 14 0 MAX 12 3 DIM C 50 5 75 16 35 5 94 REF 10 60 4 STD FLANGE 500 MOUNTING HOLES DIM B DIM A 3 50 00 06 05 05 01 13 FASTENERS AND O RING ARE INCLUDED WITH PENTAIR POOL PRODUCTS EQ 6...

Страница 27: ...EQ NOTES...

Страница 28: ...P N 350061 Rev E 1 24 06...

Отзывы: