EQ Series Pump Installation and User’s Guide

Disassembly

1. Ensure the electric supply circuit is disconnected and is properly tagged and locked out.

2. Disconnect the line supply conductors and the ground conductor from the motor (1) if the motor is being

replaced.

3. Close any valves required to prevent flooding when the pump is disassembled.

4. Review the parts breakdown in Section 8, to understand how the pump components are assembled together.

5. Remove the pump housing (22) drain plug (24) and allow the pump to completely drain.

6. Remove the four 5/8 in. hex nuts (23) that secure the motor end assembly to the front housing (22).

7. If the motor support (2) is bolted to a permanent surface it will be necessary to remove the screws (6) that are

securing the motor to the motor support (2) to allow for removal of the motor end assembly.

8. Grasp the motor end assembly and pull backwards. It may be necessary to wiggle the motor assembly from

side to side to break free the O-Ring seals inside the pump.

9. Pull the motor end assembly free of the housing (22) so that there is adequate access to the internal components.

If desired, the supply conductors can be disconnected and the motor end assembly can be taken to a workbench
for easier service.

10. Remove the four screws (20) with washers (18) (19) that secure the diffuser (17) to the seal plate (13).

11. Hold the impeller (15) nose and remove the screw (16) and washers (4) (5) that secure the impeller (15).

12. The impeller (15) is also secured to the shaft by a parallel key      . The impeller (15) can be freed from the

shaft and key by grasping the outside of the impeller (15) and pulling the impeller (15) away from the motor
(1). It is good practice to inspect the impeller (15) to ensure that the vane passageways are open and that no
vanes have been substantially broken or worn.

13. Removing the impeller (15) will expose the two pieces of the mechanical seal (14). It will not be necessary to

further disassemble the pump if only a seal replacement is required.

14. The seal plate (13) is attached to the motor adaptor (7) by two dowel pins (26). The seal plate (13) can be freed

from these dowel pins (26) by grasping the outside of the seal plate (13) and pulling way from the motor wiggling
it from side to side if required.

15. Remove the four screws (10) with washers (8) (9) that secure the motor adaptor (7) to the motor (1). These

components could cause severe personal injury or death if they were to strike a person.

1

Содержание EQ SERIES

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide EQ SERIES High Performance Commercial Pump...

Страница 2: ...their products Pentair Water Pool and Spa Inc disclaims any proprietary interest in trademarks and trade names other than its own P N 350061 Rev E 1 24 06 Customer Service If you have questions about...

Страница 3: ...re Testing 5 Section 3 Electrical Requirements 7 Electrical Requirements and Field Wiring 7 Section 4 Initial Operation of Pump 9 Priming the EQ Series Pump 9 Section 5 Maintenance 11 Cleaning the Str...

Страница 4: ...ate the pump until you have read and understand clearly all the operating instructions and warning messages for all equipment that is a part of the pool circulating system The following instructions a...

Страница 5: ...could cause severe personal injury or death if they were to strike a person WARNING Due to the potential risk that can be involved it is recommended that the pressure test be kept to the minimum time...

Страница 6: ...suction plumbing be installed in accordance with the latest national and local codes for swimming pools These instructions contain information for a variety of pump models and therefore some instruct...

Страница 7: ...wosignificant benefits First it means more efficient performance the EQ pump moves more water more quickly than comparable pumps And secondly it means the pump s motor doesn t have to work as hard and...

Страница 8: ...ovides true breakthrough performance Lower load due to efficient impeller design means longer motor life Cam and Ramp lid design with clear lid for added convenience in servicing Additional Features C...

Страница 9: ...ipeespecially on the suction line to keep flow velocities at or below 6 feet per second fps Flow velocities in the return plumbing should not exceed 10 fps Also keep elbows and tees to a minimum Insta...

Страница 10: ...he pump CAUTION On installations where the pump is installed without a strainer pot use only 6 in Schedule 40 PVC pipe when making the final flange connection Do NOT use Schedule 80 Pipe as this can c...

Страница 11: ...signed to meet the local code test pressure Most components should be marked with a maximum operating pressure If a component is not marked consult the Owner s Instructions that came with the componen...

Страница 12: ...t of that part of the system 8 Allow the pressure to slowly build once all of the air openings are closed Close the valve between the water supply and circulation system to isolate the system from the...

Страница 13: ...integrity WARNING Risk of electrical shock or electrocution This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Elect...

Страница 14: ...ate information on the pump 5 Following the National Electrical Code and any local electrical codes connect the grounding conductor and electrical supply conductors to the motor Ensure that the pump i...

Страница 15: ...p 5 The pump will experience a temporary unstable condition as water and air flow through the pump During this unstable condition the pump may be noisy and produce erratic flow If the pump is below or...

Страница 16: ...10 EQ Series Pump Installation and User s Guide...

Страница 17: ...G If the pump has been energized for a period greater than 45 minutes without water flowing through the pump for any reason the water in the strainer pot may be hot Attempting to remove the locking ri...

Страница 18: ...motor is designed to carry the pump load without building up excessive heat An increase in normal operating temperatures may indicate a potential problem Athermocoupleplacedatthemotorventilationdischa...

Страница 19: ...ng instructions before working on the pump Thepumpisdesignedtoallowforquickservicingofanymovingpartswithoutdisturbingtheplumbing connections The pump can be serviced with the common tools that are in...

Страница 20: ...ternal components Ifdesired thesupplyconductorscanbedisconnectedandthemotorendassemblycanbetakentoaworkbench for easier service 10 Remove the four screws 20 with washers 18 19 that secure the diffuser...

Страница 21: ...d screw 16 with washers 4 5 to secure the impeller 15 It is important that the screw 16 be tightened securely and that the impeller 15 is fully seated 9 Apply a light film of silicone grease to the in...

Страница 22: ...ged Closed Valve in Piping System Air leak in Suction Line Pump installed more than 10 ft above Water Level or otherwise too high for Hydraulic Conditions of Pool Plumbing System Pump Shaft rotating i...

Страница 23: ...s EQ300 EQ500 EQ750 3PH qty 4 7 356790 Adapter Motor EQ Series 8 075842 Washer Flat ID x 1 OD 125 Thk 300 s s qty 4 9 350063 Washer Split Lock 1 2 18 8 s s qty 4 10 354290 Screw 3 8 16 x 1 Hx Hd Cap 1...

Страница 24: ...HZ EQK500 50HZ METERS OF WATER CUBIC METERS PER HOUR 0 5 10 15 20 0 25 50 75 100 125 150 175 FLOW RATE IN U S GPM 0 20 40 60 80 100 120 0 100 200 300 400 500 600 700 800 900 FLOW RATE IN U S GPM TOTAL...

Страница 25: ...PUMPEQW300 1PH6 x4 PUMPEQW300 3PH6 x4 PUMPEQW500 1PH6 x4 PUMPEQW500 3PH6 x4 PUMPEQ500 1PH6 x4 PUMPEQ500 3PH6 x4 PUMPEQ750 1PH6 x4 PUMPEQ750 3PH6 x4 PUMPEQ1000 3PH6 x4 PUMPEQ1500 3PH6 x4 PUMPEQK300 50...

Страница 26: ...P FOR 6 STD FLANGE 14 0 MAX 12 3 DIM C 50 5 75 16 35 5 94 REF 10 60 4 STD FLANGE 500 MOUNTING HOLES DIM B DIM A 3 50 00 06 05 05 01 13 FASTENERS AND O RING ARE INCLUDED WITH PENTAIR POOL PRODUCTS EQ 6...

Страница 27: ...EQ NOTES...

Страница 28: ...P N 350061 Rev E 1 24 06...

Отзывы: