WHOLE HOUSE CARBON FILTRATION SYSTEM • 25
3. The valve is in regeneration.
4. Excessive water use.
5. The unit fails to regenerate.
6. Capacity of filter media is exhausted.
7. Leak between rotor and seal disk.
8. Leak at the riser tube.
9. The valve body and timer are out
of synchronization.
9. Synchronize the valve body and timer.
8. Verify that the riser tube is seated
correctly and is not cracked.
7. Check the rotor and seal disk;
replace if necessary.
6. Replace the filter bed.
5. Refer to SYMPTOM #2.
4. Check the frequency of regenerations.
3. Wait for the regeneration to complete.
TROUBLESHOOTING GUIDE
SYMPTOM
CAUSE
SOLUTION
1. Untreated water
to service.
1. Open bypass valve.
1. Close the bypass valve.
1. Faulty electrical supply.
2. The control is not set properly.
3. The drive motor is defective.
4. The flow meter is defective.
5. The computer board is defective.
6. The microswitches are defective.
6. Replace the microswitches.
5. Replace the computer board.
4. Replace the flow meter.
3. Replace the drive motor.
2. Verify the correct regeneration
schedule and reset the control.
1. Check the electrical items
(fuse, transformer).
2. The unit fails
to regenerate.
If the troubleshooting guide did not resolve the unit’s symptoms, please contact your local Dealer for service.
2. Refer to SYMPTOM #4.
2. Loss of filter media.
10. Media exhausted or consumed.
10. Add or replace media .