Pentair Pool Products SM/SMBW 2000 Скачать руководство пользователя страница 5

iii

SM/SMBW 2000 Series™ Filter Installation and User’s Guide

IMPORTANT SAFETY PRECAUTIONS 

(continued)

 WARNING —

Due to the potential risk that can be involved it is recommended that the pressure test be kept to the
minimum time required by the local code. Do not allow people to work around the system when the
circulation system is under pressure test. Post appropriate warning signs and establish a barrier
around the pressurized equipment. If the equipment is located in an equipment room, lock the door
and post a warning sign.

Never attempt to adjust any closures or lids or attempt to remove or tighten bolts when the system is
pressurized. These actions can result in a separation or failure of system components. This
instantaneous release of energy can cause components to be accelerated to high velocities and to
travel far distances. These components could cause severe personal injury or death if they were to
strike a person.

 

WARNING

 —

Risk of electrical shock or electrocution.

This pool filter must be installed by a qualified pool serviceman in accordance with the National
Electrical Code and all applicable local codes and ordinances.

Always disconnect power to the pool equipment at the circuit breaker before servicing any of the
equipment. Ensure that the disconnected circuit is locked out or properly tagged so that it cannot be
switched on while you are working on the pool equipment. Failure to do so could result in serious injury
or death to serviceman, pool users or others due to electric shock.

Position the filter and the air relief valve to safely direct water drainage and purged air or water. Water
discharged from an improperly positioned filter or valve can create an electrical hazard that can cause
severe personal injury as well as damage property.

 WARNING

 —

To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times.

 CAUTION —

This filter is for use with permanently installed pools and may also be used with hot tubs and spas if
so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the
ground or in a building such that it cannot be readily disassembled for storage. A storable pool is
constructed so that it may be readily disassembled for storage and reassembled to its original
integrity.

Содержание SM/SMBW 2000

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide SM SMBW 2000 Series Filter...

Страница 2: ...marks and names or their products Pentair Water Pool and Spa Inc disclaims any proprietary interest intrademarks and trade names other than its own P N 075122 Rev E 4 5 06 Customer Service If you hav...

Страница 3: ...ter Precoating Installations 4 Section 3 Filter Installation 5 General Information 5 Operating the Filter 6 Section 4 Maintenance 7 Backwashing Cleaning the SM SMBW 2000 Series Filter 7 Cleaning the S...

Страница 4: ...her service of the circulating system A Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing B opentheHighFlow manualairreliefva...

Страница 5: ...ce with the National Electrical Code and all applicable local codes and ordinances Always disconnect power to the pool equipment at the circuit breaker before servicing any of the equipment Ensure tha...

Страница 6: ...waste piping separation tank requirements and spent D E disposal requirements DO NOT use more than the recommended amount of D E in your filter To do so can cause a buildup of D E and bridging betwee...

Страница 7: ...better they make your life easier That s because they feature curved grids to maximize filter surface area and more filter area means longer periods between cleaning In addition a refined internal de...

Страница 8: ...and without backwash valves to meet your exact requirements Exclusive clamp ring design permits quick and easy access to internal components should service be necessary 2 plumbing connections for maxi...

Страница 9: ...has been listed and approved by the National Sanitation Foundation This booklet will enable you to install and operate your pool filter in the correct manner Correct installation and operation will r...

Страница 10: ...roviding countless microscopic channels which entrap suspended impurities but allow clear water to pass through withoutclogging 4 We recommend the use of D E which is sold and labeled for use with swi...

Страница 11: ...cording to instructions provided 1 New pools have a tremendous amount of debris due to dirt in the lines plaster dust etc This debris will be removed by the filter and will require daily backwashing o...

Страница 12: ...from the filter This will allow you enough room to stand clear of the filter during system start up 11 Allow sufficient clearance around the filter to permit visualverificationthattheclampisproperlyin...

Страница 13: ...B is closed See Figure 3 WARNING Valve D is the air relief valve It is important that this valve be opened before proceeding further The tank is pressurized and is dangerous if the air is not vented...

Страница 14: ...Use garden hose to rinse down filter elements until all debris has been flushed from tank Then screw drain plug on backwash line on models with Separation Tank 8 Unscrew wing nut remove washer and un...

Страница 15: ...e tool fits under the O Ring 5 Liftthetanklidwiththefilterlidopenerinseveralplacesaroundthetank 6 Consultpage7forFilterCleaningandpages5and6forFilterOperating Instructions Lid O ring Filter Lid Opener...

Страница 16: ...b E D g n i w o l l a n w o d n i a r d o t m e t s y s e s u a c l o o p p a c t n e v g n i s s i M p a c e c a l p e R d i L t a k a e L g n i R O d e g a m a D g n i R O e c a l p e R g n i R O d...

Страница 17: ...0 30 074925 Element 2072 36 074926 7 Manifold 2000 Series 8 Hole 073270 1 8 O Ring Channel w Red Line 071442 1 9 Tank SM Less Collector 1 SM 2036 073437 SM 2048 073438 SM 2060 073439 SM 2072 073440 Ta...

Страница 18: ...alve Model SMBW w Noryl Rotor Item Description P N Qty Valve BW w Noryl Rotor Complete 073462 1 1 Screw 1 4 20 x 5 8 HH s s 074927 6 2 CompressionRing 070731 1 3 O Ring 2 228 Collar Rotor 071426 1 4 R...

Страница 19: ...SM SMBW2000 NOTES...

Страница 20: ...P N 075122 Rev E 4 5 06...

Отзывы: