Pentair Pool Products SM/SMBW 2000 Скачать руководство пользователя страница 14

8

SM/SMBW 2000 Series™ Filter Installation and User’s Guide

How to Clean Filter Manually & Winterizing Instructions

 (Required at least once a year and when winterizing your filter to prevent damage during freezing conditions.)

1. Turn pump off.

2. Set valve handle or valves for backwash position, (for SMBW only).

3.

STAND CLEAR OF THE FILTER

 - Turn pump on and run for 3 minutes, then turn pump off.

4. Drain filter with respect to opening the air relief valves as discussed in a, b, and c, below.

a. To drain filter Model SM with gate valves, open drain valve and tank air relief valve and close all other

valves.

 

WARNING

 —

Valve "D" is the air relief valve.

 

It is important that this valve be opened before proceeding

further. 

The tank is pressurized and is dangerous if the air is not vented prior to removing the lid

clamp. Failure to open the air relief valve could cause the lid to separate resulting is serious bodily
injury and/or property damage.

b. To drain filter model SMBW, set valve handle to backwash position and open tank air relief valve.
c. To drain filter model SMBW with Separation Tank, set valve handle to backwash position; open tank air

relief valve; close all other valves and remove drain plug on backwash line.

5. To remove the clamping ring, partially unscrew the adjustment knob and release the head of the T-bolt from

the slotted bracket.

6. Remove tank lid with screwdriver or with a tool available from the manufacturer, see 

page 9,

 Figure 5. Avoid

cutting rubber O-ring or bending of lid or tank O-ring channel.

7. Use garden hose to rinse down filter elements until all debris has been flushed from tank. Then screw drain

plug on backwash line on models with Separation Tank.

8. Unscrew wing nut; remove washer and unclip air vent tube from holding wheel. Remove holding wheel.

 

WARNING

 —

Please heed all manufacturers' posted instructions, warnings and cautions when using
muriatic acid.

9. Lift out filter elements and scrub each element with a soft brush. If elements are coated with scale, it will be

necessary to brush with a mild solution of muriatic acid (10 parts water to 1 part muriatic acid). Rinse elements

with water.

10. Remove manifold and inspect for damage. Replace rotor O-ring & lubricate as needed.
11. Replace clean elements in manifold sockets; notch on element will guide it to proper position. All elements are

interchangeable.

12. Replace holding wheel over center rod; place washer over rod and turn holding wheel until elements spread

to widest gap. Replace washer, then screw wing nut on rod. 

Do not tighten nut beyond finger tight

. Be

sure to clip air vent tube back into slot on holding wheel. Clean vent tube screen cap of any debris.

13. Remove rubber O-ring and clean both O-ring and channel. Lubricate O-ring with a non-water soluble grease

or silicone lubricant and replace O-ring in channel.

14. Clean the inside surface of the tank lid where it seals against the O-ring. Place lid on tank; push down on lid

to seat in place.

15. Replace the clamping ring. Engage the head of the T-bolt into the slotted bracket and tighten the adjustment

knob. (Hand tighten only.)

16. To restore to the filter cycle, refer to the operating and cleaning instructions of the filter model involved. When

winterizing, ensure that all water is removed from the lower internal portion of the filter.

Содержание SM/SMBW 2000

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide SM SMBW 2000 Series Filter...

Страница 2: ...marks and names or their products Pentair Water Pool and Spa Inc disclaims any proprietary interest intrademarks and trade names other than its own P N 075122 Rev E 4 5 06 Customer Service If you hav...

Страница 3: ...ter Precoating Installations 4 Section 3 Filter Installation 5 General Information 5 Operating the Filter 6 Section 4 Maintenance 7 Backwashing Cleaning the SM SMBW 2000 Series Filter 7 Cleaning the S...

Страница 4: ...her service of the circulating system A Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing B opentheHighFlow manualairreliefva...

Страница 5: ...ce with the National Electrical Code and all applicable local codes and ordinances Always disconnect power to the pool equipment at the circuit breaker before servicing any of the equipment Ensure tha...

Страница 6: ...waste piping separation tank requirements and spent D E disposal requirements DO NOT use more than the recommended amount of D E in your filter To do so can cause a buildup of D E and bridging betwee...

Страница 7: ...better they make your life easier That s because they feature curved grids to maximize filter surface area and more filter area means longer periods between cleaning In addition a refined internal de...

Страница 8: ...and without backwash valves to meet your exact requirements Exclusive clamp ring design permits quick and easy access to internal components should service be necessary 2 plumbing connections for maxi...

Страница 9: ...has been listed and approved by the National Sanitation Foundation This booklet will enable you to install and operate your pool filter in the correct manner Correct installation and operation will r...

Страница 10: ...roviding countless microscopic channels which entrap suspended impurities but allow clear water to pass through withoutclogging 4 We recommend the use of D E which is sold and labeled for use with swi...

Страница 11: ...cording to instructions provided 1 New pools have a tremendous amount of debris due to dirt in the lines plaster dust etc This debris will be removed by the filter and will require daily backwashing o...

Страница 12: ...from the filter This will allow you enough room to stand clear of the filter during system start up 11 Allow sufficient clearance around the filter to permit visualverificationthattheclampisproperlyin...

Страница 13: ...B is closed See Figure 3 WARNING Valve D is the air relief valve It is important that this valve be opened before proceeding further The tank is pressurized and is dangerous if the air is not vented...

Страница 14: ...Use garden hose to rinse down filter elements until all debris has been flushed from tank Then screw drain plug on backwash line on models with Separation Tank 8 Unscrew wing nut remove washer and un...

Страница 15: ...e tool fits under the O Ring 5 Liftthetanklidwiththefilterlidopenerinseveralplacesaroundthetank 6 Consultpage7forFilterCleaningandpages5and6forFilterOperating Instructions Lid O ring Filter Lid Opener...

Страница 16: ...b E D g n i w o l l a n w o d n i a r d o t m e t s y s e s u a c l o o p p a c t n e v g n i s s i M p a c e c a l p e R d i L t a k a e L g n i R O d e g a m a D g n i R O e c a l p e R g n i R O d...

Страница 17: ...0 30 074925 Element 2072 36 074926 7 Manifold 2000 Series 8 Hole 073270 1 8 O Ring Channel w Red Line 071442 1 9 Tank SM Less Collector 1 SM 2036 073437 SM 2048 073438 SM 2060 073439 SM 2072 073440 Ta...

Страница 18: ...alve Model SMBW w Noryl Rotor Item Description P N Qty Valve BW w Noryl Rotor Complete 073462 1 1 Screw 1 4 20 x 5 8 HH s s 074927 6 2 CompressionRing 070731 1 3 O Ring 2 228 Collar Rotor 071426 1 4 R...

Страница 19: ...SM SMBW2000 NOTES...

Страница 20: ...P N 075122 Rev E 4 5 06...

Отзывы: