Pentair Pool Products SM/SMBW 2000 Скачать руководство пользователя страница 4

ii

SM/SMBW 2000 Series™ Filter Installation and User’s Guide

IMPORTANT SAFETY PRECAUTIONS

Consumer Information and Safety

The SM/SMBW 2000 Series™ Filters are designed and manufactured to provide many years of safe and reliable service
when installed, operated and maintained according to the information in this manual and the installation codes referred
to in later sections. Throughout the manual, safety warnings and cautions are identified by the “      “ symbol. Be sure
to read and comply with all of the warnings and cautions.

 WARNING

 —

Do not operate the filter until you have read and understand clearly all the operating instructions
and warning messages for all equipment that is a part of the pool circulating system. The
following instructions are intended as a guide for initially operating the filter in a general pool
installation, however each installation may have unique conditions where the starting procedure
could be different. Failure to follow all operating instructions and warning messages can result
in severe injury, death, or property damage.

 

WARNING

 

THIS FILTER OPERATES UNDER HIGH PRESSURE.

When any part of the circulating system, (e.g., clamp, pump, filter, valve(s), etc.), is serviced, air
can enter the system and become pressurized. Pressurized air can cause the lid to be blown off
which can result in severe injury, death, or property damage. To avoid this potential hazard, follow
these instructions:

1.

Before repositioning valve(s) and before beginning the assembly, disassembly, or adjustment
of the clamp or any other service of the circulating system: (A) Turn the pump 

OFF

 and 

shut

OFF 

any automatic controls to ensure the system is NOT inadvertently started during the

servicing; (B) open the

 

High Flow™ manual air relief valve; (C) wait until all pressure is relieved.

2.

Whenever installing the filter clamp 

FOLLOW THE

 

FILTER CLAMP INSTALLATION

INSTRUCTIONS EXACTLY

.

3.

Once service on the circulating system is complete 

FOLLOW SYSTEM RESTART

INSTRUCTIONS EXACTLY

.

4.

Maintain circulation system properly. Replace worn or damaged parts immediately,
(e.g., clamp, pressure gauge, valve(s), o-rings, etc).

5.

Be sure that the filter is properly mounted and positioned according to instructions provided.

 

 

Important Notice:

This guide provides installation and operation instructions for the SM/SMBW 2000 Series

™   

Filter.

Consult Pentair Water Pool and Spa

 with any questions regarding this equipment.

Attention Installer: 

This guide contains important information about the installation, operation and safe use of

this product. This information should be given to the owner and/or operator of this equipment after installation or left on
or near the filter.

Attention User: 

This manual contains important information that will help you in operating and maintaining this

filter. Please retain it for future reference.

 WARNING

 —

Before installing this product, read and follow all warning notices and instructions which are
included. Failure to follow safety warnings and instructions can result in severe injury, death,
or property damage.  Call (800) 831-7133 for additional free copies of these instructions.

H

ea

d

Body

U

pp

er

A

rm

Upper

Arm

Leg Joint

Leg

 J

oin

t

Leg Joint

Le

g Jo

int

H

ea

d

Bo

dy

U

pp

er

Ar

m

Leg J

oin

t

Leg

 J

oin

t

Leg

 J

oin

t

Leg Joint

Содержание SM/SMBW 2000

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide SM SMBW 2000 Series Filter...

Страница 2: ...marks and names or their products Pentair Water Pool and Spa Inc disclaims any proprietary interest intrademarks and trade names other than its own P N 075122 Rev E 4 5 06 Customer Service If you hav...

Страница 3: ...ter Precoating Installations 4 Section 3 Filter Installation 5 General Information 5 Operating the Filter 6 Section 4 Maintenance 7 Backwashing Cleaning the SM SMBW 2000 Series Filter 7 Cleaning the S...

Страница 4: ...her service of the circulating system A Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing B opentheHighFlow manualairreliefva...

Страница 5: ...ce with the National Electrical Code and all applicable local codes and ordinances Always disconnect power to the pool equipment at the circuit breaker before servicing any of the equipment Ensure tha...

Страница 6: ...waste piping separation tank requirements and spent D E disposal requirements DO NOT use more than the recommended amount of D E in your filter To do so can cause a buildup of D E and bridging betwee...

Страница 7: ...better they make your life easier That s because they feature curved grids to maximize filter surface area and more filter area means longer periods between cleaning In addition a refined internal de...

Страница 8: ...and without backwash valves to meet your exact requirements Exclusive clamp ring design permits quick and easy access to internal components should service be necessary 2 plumbing connections for maxi...

Страница 9: ...has been listed and approved by the National Sanitation Foundation This booklet will enable you to install and operate your pool filter in the correct manner Correct installation and operation will r...

Страница 10: ...roviding countless microscopic channels which entrap suspended impurities but allow clear water to pass through withoutclogging 4 We recommend the use of D E which is sold and labeled for use with swi...

Страница 11: ...cording to instructions provided 1 New pools have a tremendous amount of debris due to dirt in the lines plaster dust etc This debris will be removed by the filter and will require daily backwashing o...

Страница 12: ...from the filter This will allow you enough room to stand clear of the filter during system start up 11 Allow sufficient clearance around the filter to permit visualverificationthattheclampisproperlyin...

Страница 13: ...B is closed See Figure 3 WARNING Valve D is the air relief valve It is important that this valve be opened before proceeding further The tank is pressurized and is dangerous if the air is not vented...

Страница 14: ...Use garden hose to rinse down filter elements until all debris has been flushed from tank Then screw drain plug on backwash line on models with Separation Tank 8 Unscrew wing nut remove washer and un...

Страница 15: ...e tool fits under the O Ring 5 Liftthetanklidwiththefilterlidopenerinseveralplacesaroundthetank 6 Consultpage7forFilterCleaningandpages5and6forFilterOperating Instructions Lid O ring Filter Lid Opener...

Страница 16: ...b E D g n i w o l l a n w o d n i a r d o t m e t s y s e s u a c l o o p p a c t n e v g n i s s i M p a c e c a l p e R d i L t a k a e L g n i R O d e g a m a D g n i R O e c a l p e R g n i R O d...

Страница 17: ...0 30 074925 Element 2072 36 074926 7 Manifold 2000 Series 8 Hole 073270 1 8 O Ring Channel w Red Line 071442 1 9 Tank SM Less Collector 1 SM 2036 073437 SM 2048 073438 SM 2060 073439 SM 2072 073440 Ta...

Страница 18: ...alve Model SMBW w Noryl Rotor Item Description P N Qty Valve BW w Noryl Rotor Complete 073462 1 1 Screw 1 4 20 x 5 8 HH s s 074927 6 2 CompressionRing 070731 1 3 O Ring 2 228 Collar Rotor 071426 1 4 R...

Страница 19: ...SM SMBW2000 NOTES...

Страница 20: ...P N 075122 Rev E 4 5 06...

Отзывы: