Section 7
IntelliComm system wiring
The IntelliComm provides four pairs of input terminals which can be actuated by either 15 to
240 VAC or 15 to 100 VDC from the source device, (automation controller, heater, heat pump
etc.). There are four IntelliFlo external control programs that can be enabled.
Note:
The IntelliComm will always be configured to communicate to pump address 1.
IntelliComm system wiring table
Section 8
IntelliComm electrical specifications
Power Requirements:
The IntelliComm draws less than 1 amp. Over current protection of
the wires connecting the source device, (automation controller, heater, heat pump etc.) to the
IntelliComm must be provided at the source.
Inputs from remote device:
The IntelliComm has four current sensing inputs that are
activated by either
15 VAC to 240 VAC or 15 VDC to 100 VDC.
Output to IntelliFlo pumps:
The IntelliComm communicates with IntelliFlo pumps via a two
wire RS-485 Serial link.
Note: (*) indicates current controlled input, voltage independent.
Terminal number
Terminal name
Voltage
Maximum current
Phase type
Frequency
1-2
Power supply
100 - 240 VAC
100 mA
1 Input
50/60 Hz
3-4
Program 1
15 -240 VAC
or
15 - 100 VDC
1 mA*
1 Input
50/60 Hz
5-6
Program 2
15 -240 VAC
or
15 - 100 VDC
1 mA*
1 Input
50/60 Hz
7-8
Program 3
15 -240 VAC
or
15 - 100 VDC
1 mA*
1 Input
50/60 Hz
9-10
Program 4
15 -240 VAC
or
15 - 100 VDC
1 mA*
1 Input
50/60 Hz
11
12
RS-485
+ Data: Yellow
- Data: Green
-5 to +5 VDC
5 mA
1 Output
N/A
Ground