To Remove Debris From The Flapper.
I M P O RTA N T:
The pool pump must be off
b e fo re re m oving the cleaner from the pool.
• Sometimes debris may clog the
bottom of the cleaner and prevent
flapper movement or restrict flow.
The flapper is located inside the
main body and must move freely
at all times.
• You can see the flapper through the
opening in the baffle plate when
you turn the cleaner upside down,
as shown in Figure 20. Jiggle the
flapper with your finger or flush
the cavity with a hose to force
out a ny deb ris lodged inside the
main body.
• If debris is still lodged inside, you
must remove the flapper. First, lift
the lip of the foot pad up and insert
a flat-headed screwdriver along side one of the two tabs found on either side of the baffle plate.
See Figure 21. Push the tab inward with the screwdriver until the baffle plate releases. Place a
finger into the center opening of the baffle plate and pull up until it pops out. Then pull the
fl apper out.
N OT E : You should be able to do this without taking the foot pad off.
• Once the debris is dislodged, insert the flapper back into the main body and snap the baffle plate
back into position. Be sure that it is securely in place. See Figure 21.
Foot Pad
(not necessary to remove)
Baffle Plate
Flapper
Main Body
BOTTOM VIEW OF CLEANER
Foot Pad
Flapper is
inside
Baffle
Plate
Pleated
Seal
Figure 20
Figure 21
Содержание Kreepy kadet