IntelliComm II Interface Adapter Installation and User’s Guide
TO OPERATE THE INTELLIBRITE COLOR LIGHT SHOWS
3
Connecting IntelliComm II to IntelliFlo
Connection from IntelliComm II to an IntelliFlo VF or IntelliFlo VS pump is via
a 50 ft. RS-485 communication cable (P/N 350122), which is provided with
the pump.
Connecting the IntelliFlo Pump to IntelliComm II RS-485 Terminal
Connect the YELLOW and GREEN wire from the IntelliFlo communication
cable to the YELLOW and GREEN RS-485 screw terminals on the
IntelliComm II interface adapter as shown below.
IntelliComm II to IntelliFlo Pump and Pentair Water Pool and Spa
Automation Control Circuit Board Connection Diagram
RS-485 COMMUNICATION
CABLE (22 AWG)
PWR
BLK
YLW
GRN
RED
GPM/RPM 1
9 - 24V DC/AC
YLW
GRN
RELAY 4
RELAY 3
RELAY 2
RELAY 1
9 - 24V DC/A
C
P
e
n
tair
W
a
ter P
o
ol and Spa
A
u
toma
tion C
o
n
tr
ol B
oar
d
GND
RED
BLK
PWR
GND
GPM/RPM 2
GPM/RPM 3
GPM/RPM 4
(used with SunT
ouch,
EasyT
ouch
and In
telliT
ouch)
(PROGRAM 1)
(PROGRAM 2)
(PROGRAM 3)
(PROGRAM 4)
VLV A VLV B
INTAKE RTRN
VL
V A
IntelliComm II
Automation
Circuit Board
9 - 24 VDC
WHITE
RED
BLK
or
Note:
Connect GPM/RPM 1, 2, 3, and 4 to any
control output or auxiliary relay circuit (RELAY
1-4) on the automation circuit board. Typically,
GPM/RPM 1 connects to Filter Pump.
If more
than one terminal input is active, the highest
input number (GPM/RPM 4) will take priority
regardless of the pump setting.
Note: The black wire
must be used.
Choosing either the
Red or White wire
will depend on the
direction that the
actuator needs to
rotate to the spa.