IntelliComm II Interface Adapter Installation and User’s Guide

 Important Notice:

 

Attention Installer: 

This manual contains important

information about the installation, operation and safe use of this product.
This information should be given to the owner and/or operator of this
product. 

READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL

.

Contents

IntelliComm

®

 II

 

Interface Adapter Overview ...................................................... 1

IntelliComm II Interface Adapter Connections .................................................. 2
Connecting to IntelliComm II Input Program Terminals .................................... 2
Connecting Power to IntelliComm II ................................................................. 2
Connecting IntelliComm II to IntelliFlo .............................................................. 3
Connecting to a Compool

®

 Control System ...................................................... 4

      RYA-LX Harness (P/N RYALX) Accessory .................................................. 7
Connecting to a Jandy

®

 AquaLink RS Control System .................................. 10

Connecting to a Hayward

®

 Control System .................................................... 12

Connecting to a Polaris

®

 EOS Control System ............................................... 14

Setting up an IntelliFlo

®

 VF Pump with IntelliComm II ..................................... 16

Mounting the IntelliComm II Interface Adapter ............................................... 20

i

IMPORTANT SAFETY PRECAUTIONS

© 2009 Pentair Water Pool and Spa, Inc.  All rights reserved.

1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000  • (800) 831-7133
IntelliComm

®

, IntelliFlo

®

, IntelliPro

®

, IntelliTouch

®

, EasyTouch

®

, SunTouch

®

,  Compool

®

, and Pentair Water

Pool and Spa

® 

 are trademarks and/or registered  trademarks of Pentair Water Pool and Spa, Inc. and/or its

affiliated companies in the United States and/or other countries.  Hayward

®

 and ProLogic

®

 are registered

trademarks of Hayward Industries Inc.  Jandy

®

 and AquaLink

®

 are registered trademarks of Jandy

Industries Inc. Polaris

®

 is a registered trademark of Zodiac Pool Systems, Inc.  Unless noted, names and

brands of others that may be used in this document are not used to indicate an affiliation or endorsement
between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names
and brands may be the trademarks or registered trademarks of those parties or others.

P/N 521033 - Rev C  - 10/16/09

Before installing the IntelliComm

®

 II Interface adapter , read

and follow all warning notices and instructions which are

included. Failure to follow safety warnings and instructions can result in severe
injury, death, or property damage.  Call (800) 831-7133 for additional free copies
of these instructions.

Risk of electrical shock or electrocution:

The IntelliComm II Interface adapter must be installed by a
qualified electrician, according to the National Electrical Code
(including article 680-22) or Canadian Electrical Code
(including section 68) and local codes and ordinances. The
electrician should also consult the local building department
regarding local codes.

Technical Support:

 (800) 831-7133

Improper installation will create an electrical hazard which could result in death or
serious injury to pool users, installers, or others due to electrical shock, and may
also cause damage to property.

Always disconnect power to the pool pump at the circuit breaker before
servicing the pump.

 Failure to do so could result in death or serious injury to

serviceman, pool users or others due to electric shock.

Содержание IntelliComm II

Страница 1: ...stallation and User s Guide Installation and User s Guide IntelliComm II Interface Adapter For use with IntelliFlo and IntelliPro pumps IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS S...

Страница 2: ...demarks of Hayward Industries Inc Jandy and AquaLink are registered trademarks of Jandy Industries Inc Polaris is a registered trademark of Zodiac Pool Systems Inc Unless noted names and brands of oth...

Страница 3: ...the IntelliFlo pump s speed or flow Note If more than one terminal input is active the highest input number GPM RPM 4 will take priority regardless of the pump setting A four screw terminal connector...

Страница 4: ...rminal Connects to the pump via a two pin 50 ft communication cable P N 350122 provided with the pump Also connects to a 9 24VDC 200mA power source automa tion control system circuit board Four 9 24V...

Страница 5: ...iagram RS 485 COMMUNICATION CABLE 22 AWG PWR BLK YLW GRN RED GPM RPM 1 9 24V DC AC YLW GRN RELAY 4 RELAY 3 RELAY 2 RELAY 1 9 24V DC AC Pentair Water Pool and Spa Automation Control Board GND RED BLK P...

Страница 6: ...from RJ12 to IntelliComm II Red PWR screw terminal Note To avoid circuit board damage DO NOT connect the RED andYELLOW wires together to Red PWR terminal leave RED UNCONNECTED see page 6 2 Connect RJ1...

Страница 7: ...SOL POOL EHTR POOL SOL SPA SOL GRN RED TEMPERATURE SENSORS SPA HEAT PHONE CONTROLS POOL FLR CLN AUX VLV CNTRL AUX VLV TO CONTROL PANEL RED BLK GRN YLW RED PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24V DC AC RS485...

Страница 8: ...L RED NOT CONNECTED BLK GRN YLW RED PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24 VDC RS485 RS 485 PIN 3 GRN PIN 2 YLW TO PUMP RJ12 ADAPTER TO COM PORT LX100 use black plug IntelliFlo pump LX 100 ONLY YLW GND PWR...

Страница 9: ...8 CAUTION DO NOT SHORT PINS OF RELAY SOCKETS GND HLMP HBST SPA POOL REM1 REM2 REM3 REM4 REM5 REM6 18 10 24 PART PC LX3830 COMPOOL 11010B SPA 2SPD SFLT PFLT AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 FREEZE I L SY...

Страница 10: ...lo pump BLK GND YLW GRN RED 9 24V DC PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24V DC AC PWR GND From Compool circuit board From Compool circuit board Connect to Compool circuit board see page 4 Choose the functi...

Страница 11: ...face Adapter Installation and User s Guide 9 BLACK GND Swim Master LX20 CP2000 and Time Master LX10 BLACK GND RED 24 VDC BLACK GND RED 24 VDC CP1000 RED 24 VDC BLACK GND RED 24 VDC CP2020 BLACK GND RE...

Страница 12: ...lay circuit on the Jandy circuit board Typically GPM RPM 1 connects to the output Filter Pump relay terminal plug However Jandy auxiliary relay circuits can be connected to any of the four input termi...

Страница 13: ...m II mounted inside low voltage compartment of Power Center RS485 YLW GRN BLK YLW GRN RED PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24V DC AC GND PWR GND CHOOSE FUNCTION for connection to IntelliComm II RELAY 4 I...

Страница 14: ...e upper and lower relay bracket and remove the brackets 4 Attach wires to the FILTER PUMP relay screws terminals Loosen the two top relay terminal screws with attached wires Using the provided auxilia...

Страница 15: ...IntelliComm II Interface Adapter Installation and User s Guide 9 24V DC AC 9 24 VDC 13 IntelliComm II to Hayward Pro Logic Control System Connection Diagram...

Страница 16: ...cting AUX cables 2 Connect the auxiliary cables provided in kit from the IntelliComm II input terminals GPM RPM 1 2 3 and 4 to any control output or auxiliary relay circuit on the Polaris circuit boar...

Страница 17: ...LAY3 RELAY2 RELAY1 9 24V DC AC PWR GND From Polaris circuit board From Polaris circuit board Connect to Polaris circuit board Choose the function on the Polaris circuit board HP1 HP8 VLV1 VLV 6 Polari...

Страница 18: ...its filter cycle This is done on the IntelliFlo keypad under Menu Filter Address 1 is the default address for the IntelliFlo VF The IntelliComm II will only communicate with address 1 The pump s Addre...

Страница 19: ...ets a command to run a speed from the IntelliComm II it will run the new commanded speed and the LED above the new speed will be illuminated When the command from the IntelliComm II has stopped the pu...

Страница 20: ...page 10 for the IntelliFlo VF steps 1 through 12 However there is one difference The IntelliFlo VS SVRS does not have any default Schedules so it is not necessary to deactivate any schedules so it wil...

Страница 21: ...c x E s a h n a f r o t o m e h t e r u s n E 1 n o i t a l i t n e v r o f a e r a e t a u q e d a o t d e e p s r e h g i h a t a r o t o m n u R 2 w o l f r i a g n i l o o c e v o r p m i 7 m r a...

Страница 22: ...t board Be careful not to touch the circuit board components Hold the circuit board by the edges Place the circuit board aside Drill two mounting screws holes for the back cover 3 Cut out the template...

Страница 23: ...IntelliComm II Interface Adapter Installation and User s Guide IntelliComm II Back Cover Template Cut Out Cut Out...

Страница 24: ...IntelliComm II Interface Adapter Installation and User s Guide P N 521033 Rev C 521033...

Отзывы: