![Pentair Pool Products IntelliComm II Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/pentair-pool-products/intellicomm-ii/intellicomm-ii_installation-and-user-manual_1525883003.webp)
IntelliComm II Interface Adapter Installation and User’s Guide
1
IntelliComm
®
II interface adapter kit contents
•
IntelliComm II Interface Adapter
•
Two mounting screws
•
Mounting tape
•
One Terminal Connector (RS-485 and IntelliComm II power connection)
•
Compool RJ12 Adapter
•
Four AUX cables (22 AWG)
•
Installation and User’s Guide (this manual)
IntelliComm
II interface adapter overview
The IntelliComm II
interface adapter
provides automatic control of IntelliFlo
®
VF ,
IntelliFlo VS and IntelliPro
®
pumps. IntelliComm II is compatible with IntelliTouch
®
,
EasyTouch
®
, SunTouch
®
, Compool
®
, Hayward
®
, Jandy
®
and Polaris
®
EOS control
systems. The IntelliComm II Interface adapter provides:
Four input (9-24V DC/AC) program terminals (GPM/RPM 1, 2, 3,
and 4) for connection to any available auxiliary relay, valve actuator or controlled
output circuit on the automation control system circuit board. Typically, GPM/RPM 1
connects to the output Filter Pump relay terminal plug. You can also connect to the
spa, pool electric heater, solar or 2-speed pump output circuit. Each of the four
inputs can be used to control the IntelliFlo pump's speed or flow.
Note:
If more
than one terminal input is active, the highest input number (GPM/RPM 4) will
take priority regardless of the pump setting.
A four screw terminal connector for connection to the RS-485 IntelliFlo
communication cable and power source (9-24V DC) from the automation control
system circuit board.
Note:
The IntelliComm II Interface adapter will always use
ADDRESS 1
to
communicate with the IntelliFlo pump.
Note:
The IntelliComm II Interface adapter can be used with IntelliTouch
®
,
EasyTouch
®
and SunTouch
®
systems, when additional pumps are required
beyond the normal system capacity.
Safety Devices:
All required safety devices, such as the IntelliFlo
VS+ SVRS (Safety Vacuum Release System) pump, are unaffected when using
the IntelliComm II.
Selecting Flow Rates (GPM) for IntelliFlo VF
The IntelliFlo VF pump can be selected to run at a specific US gallons per minute
(GPM), for each external control input:
IntelliFlo VF:
15 - 130 GPM
Selecting Pump Speeds (RPM) for IntelliFlo VS+ SVRS
and IntelliPro VS3050
The IntelliFlo VS+ SVRS, IntelliFlo VS 3050 and IntelliPro VS 3050 pump can be
selected to run at a specific speed (RPM), for each external control input:
IntelliFlo VS+ SVRS:
1100 - 3450 RPM
IntelliFlo VS 3050:
400 - 3450 RPM
IntelliPro VS 3050:
400 - 3450 RPM