26
IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
IntelliChlor “Dummy” Cell
After new pool construction has been completed, in order to prevent debris from entering the IntelliChlor
Electronic Chlorine Generator, it is recommended that the IntelliChlor Electronic Chlorine Generator
“dummy” cell (P/N 520588) be installed before installing the IntelliChlor Electronic Chlorine Generator.
After the pool system has flushed the debris from the pipes, remove the “dummy cell” and install the
IntelliChlor Electronic Chlorine Generator.
Installing the IntelliChlor Cell Assembly
Install the IntelliChlor cell assembly no closer than three (3) feet away from the heater outlet, if used. For
more information see plumbing diagrams on page 4 and 5.
Note:
For best flow sensing, provide at least 12"-18" of straight pipe in front of the cell inlet.
Note:
After new pool construction has been completed, in order to prevent debris from entering the
IntelliChlor cell assembly, it is recommended that the IntelliChlor pass-through cell (P/N 520588) be
installed before installing the IntelliChlor cell. After the pool system has flushed the debris from the
pipes, remove the pass-through cell and install the IntelliChlor cell.
Note:
Pipe couplings: Schedule 80, maximum pressure 75 psi at 70° F (21° C)
Coupling
Coupling
Содержание IntelliChlor CIC60P
Страница 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 34: ...28 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...