![Pentair Pool Products IntelliChlor CIC60P Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/pentair-pool-products/intellichlor-cic60p/intellichlor-cic60p_installation-and-user-manual_1525912014.webp)
8
IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
Operator Control Panel
(continued)
Sanitizer Output LED Indicators
These five (5) LED indicators display the percentage of time chlorine is produced. For multiple cell systems,
only the 100% setting is used for the CIC60P and CIC60S cells. When the dry contact wires on the
PRIMARY power center are closed, the cell will go to 100% and begin producing chlorine. When the dry
contact wires on the PRIMARY power center are opened, the cell will switch off the 100% light and stop
producing chlorine.
Note:
If a single CIC60P cell is connected to an IntelliTouch
®
, EasyTouch
®
or SunTouch
®
system, these
lights may slowly flash when the output is set to a value not exactly 20%, 40%, 60% 80% or 100%.
Example: 21% output setting from the IntelliTouch, EasyTouch or SunTouch will flash the 20% light.
NOTE: Multiple cell systems cannot be connected to IntelliTouch, EasyTouch or SunTouch systems.
More and Less Output Buttons
These buttons control the output setting and only operate in a single-cell system where the CIC60P is
connected to the PC100 power center, no ORP. For ORP systems, (CPC100) and multiple cell systems, these
buttons are disabled, as the output setting is set by the ORP panel.
These buttons control the percentage of
time of each hour that the is producing chlorine while the pump is on. The lights act as a bar graph: the more
lights that are on, the more that chlorine is produced. To exit
Boost
mode, press and hold both the
More
and
Less
buttons.
Boost ON/OFF
BOOST mode operates when only one CIC60P cell is used in a system. It is activated by pressing both
MORE and LESS buttons simultaneously. For multiple cell systems, BOOST mode is disabled and does not
control the output setting, only the oxidation reduction potential (ORP) system via the PRIMARY power
center. Pressing both buttons for BOOST has no effect.
Note:
If no LEDs are lit, the output is set to 0% and the IntelliChlor Electronic Chlorine Generator is
not producing chlorine.
Self-Cleaning
The IntelliChlor Electronic Chlorine Generator has a self-cleaning feature that reduces scale buildup on the
blades of the IECG. The self-cleaning cycle tends to reduce the life of the IECG, therefore, it should be used
only to the extent necessary to minimize the scale buildup on the blades. The self-cleaning cycle can be
adjusted to run every 2, 3, 4, or 5 hours, whichever is the optimal for your particular pool conditions in order to
minimize scale buildup but maximize the life of the IECG. It is factory set to two (2) hours for the first 30 days
of operation, then automatically switches to three (3) hours. To change the self-cleaning cycle, press and hold
the
Less
button for three (3) seconds. The sanitizer output display will show the number of hours in a bar
graph style. The number of output LEDs lit is the number of reverse hours. Pressing
More
or
Less
button
will change this setting.
Example:
The self-clean cycle is set to run for four (4) hours and the pool owner chooses to change it to
three (3) hours to optimize the blade cleaner cycle for your particular pool conditions. Press and hold the LESS
button for three (3) seconds. The sanitizer output display will blank, then light up the 20%, 40%, 60% and 80%
lights, four (4) total. This is a four (4) hours reverse setting. Pressing the LESS button once within ten (10)
seconds will switch off the 80% light, leaving only three (3) lights on, now at a three (3) hours reverse setting.
Wait ten (10) seconds and this mode will end automatically, returning to the original sanitizer output display.
0% - No LEDs lit - No chlorine produced - IntelliChlor Electronic Chlorine Generator is off.
20% - 1 LED lit - Produces chlorine 20% of each hour of pump run time, 12 minutes on, 48 minutes off.
40% - 2 LEDs lit - Produces chlorine 40% of each hour of pump run time, 24 minutes on, 36 minutes off.
60% - 3 LEDs lit - Produces chlorine 60% of each hour of pump run time, 36 minutes on, 24 minutes off.
80% - 4 LEDs lit - Produces chlorine 80% of each hour of pump run time, 48 minutes on, 12 minutes off.
100% - 5 LEDs lit - Produces chlorine almost 100% of each the hour of pump run time, 59 minutes on, 1 minute off.
Содержание IntelliChlor CIC60P
Страница 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Страница 34: ...28 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...