6/10 HP

SK60 Performance Curve

Pump
Servicing

Read the following instructions
carefully before replacing any
parts. Reasonable care and safe
methods should be practiced.
Check local codes and
requirements before installation.
Only a competent electrician
should make the installations.
The following steps should be
performed by an authorized 
service center.

Important: Read all directions
before replacing any parts.
Remove pump and switch from
power source before servicing.

1.

Replacing diaphragm switch.

From switch housing (9)
remove screw (8) from housing.
Replace with new switch.
Insert screw (8) into housing
(9) and tighten. Plug pump
into switch and switch into
correct power source.

2.

Replacing wide angle switch.

From motor housing (21)
remove switch tethering screw
(29). Replace with new switch
(27) with new switch tethering
screw (29). Plug pump into
switch and switch into correct
power source.

Note: To be sure wires are 
not burned or broken in cord, 
use ohmmeter for check. Set
ohmmeter scale pointer to R 2 1
scale and attach one meter lead
to white cord wire and one
meter lead to black cord lead.
Place screwdriver blade across
blade terminals of plug (1). If
cord is functional, the meter will
go to zero (0). If open (

), cord

must be replaced.

Содержание Hydromatic SK60

Страница 1: ...ewage Ejector Pump SK60 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Страница 2: ...esult in injury or death General Information Pump Warning 7 For proper automatic operation make sure the pump power cord is plugged into the piggyback receptacle on the diaphragm switch cord Do not cut crimp or bend switch power cord The vent tube needs to breathe for proper operation of switch This may cause pump failure and void warranty 8 Connect to separate electrical circuit taken directly fr...

Страница 3: ... 1 Replacing diaphragm switch From switch housing 9 remove screw 8 from housing Replace with new switch Insert screw 8 into housing 9 and tighten Plug pump into switch and switch into correct power source 2 Replacing wide angle switch From motor housing 21 remove switch tethering screw 29 Replace with new switch 27 with new switch tethering screw 29 Plug pump into switch and switch into correct po...

Страница 4: ...ughly All sand and dirt must be removed Remove stationary ceramic seat of seal 10 from seal plate Push new ceramic seat into seal plate Use Parker O ring Lube on rubber ring Replace rotor in seal plate 13 Use care in putting shaft through ceramic seat to be sure it is not chipped Inspect seal after shaft is in place If seal has been chipped it must be replaced Do not replace rotating part of seal ...

Страница 5: ...tor housing will result 14 Fasten the ground wire 22 inside the motor housing and tuck wires up into the housing to prevent rubbing on the rotor then assemble housing 21 to volute 14 with bolts 6 15 Check for seal leaks by pressurizing the pump to 7 to 9 pounds of air pressure Air bubbles should appear at first then stop If air bubbles continue recheck seals Hydromatic pumps have a small air vent ...

Страница 6: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 7: ...03A052 Capscrew 2 Discharge 2 19103A043 Capscrew 3 Discharge 2 18 77 003 1 O Ring 1 19 12709 000 2 Adapter 1 20 13371 100 1 Motor 115 1 60 1 13372 100 1 Motor 230 1 60 1 13373 100 1 Motor 200 1 60 1 20 10834 300 1 Motor 200 3 60 1 10834 100 1 Motor 230 460 3 60 1 10878 700 1 Motor 575 3 60 1 21 56 036 2 Motor Housing 1Ø 1 56 023 2 Motor Housing 3Ø 1 22 19100A012 Capscrew 4 23 6000 082 1 Wire Termi...

Страница 8: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Отзывы: